6 X 2MW Electric Power Station Four Stroke Generator Set Pressure Lubrication Method

Brand Name:KANGWEI
Certification:CCS,BV,GL
Model Number:According to the design and technical demand
Minimum Order Quantity:1SET
Delivery Time:Negotiate
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Active Member
Location: Wuxi Jiangsu China
Address: NO.8, YINGHUI ROAD, MASHAN TECHNOLOGICAL INDUSTRY PARK WUXI, CHINA
Supplier`s last login times: within 4 hours
Product Details Company Profile
Product Details

6 X 2MW Electric Power Station Four Stroke Generator Set Pressure Lubrication Method


Technical specificaiton for HFO Power plant equipments
Ⅰ. Gen-set technical specification
No.ItemUnitSpecification
1Model 1250/2000/2500/3500GF
2Rated powerkW1250/2000/250003500
3Rated rev.rpm600
4Rated voltageV11000
5Rated currentA229.6
6FrequencyHz50Hz
7Power factor 0.8 (lagging)
8Phase 3-phase
9Voltage fluctuation rate%±1
10Frequency (rev.) fluctuation rate%±0.5
11Stable voltage regulating rate%±2.5
12Stable frequency (rev.) regulating rate%5
13Transient voltage regulating rate%±20~-15
14Stabilizing times5
15Voltage regulating method Auto
16Speed Governor Electronic hydraulic
17Frequency regulating method Auto/Manual
18Lubricating method Pressure lubricating
19Cooling method Close circuit of fresh cooling water
20Coupling Flexiable
21Painting color Blue
22Overall dimensionmm9890x2560x4015
23Net weightkg75000
Ⅱ. Diesel engine specification
No.ItemUnitSpecification
1Engine Model DN8340ZD2
2Type In-line, 8-Cyls, four-stroke, direct injection, charged, inter cooled
3Boremm340
4Strokemm450
5Total displacemenL408.35
6Mean piston seedm/s9
7Rated powerKW4200
8Rated rev.rpm600
9Overload (1 hr per 12 hrs)kW/rpm4620/600
10Mean effective pressureMPa2.56
11Compression ratio 13.5
12Rotation direction Clockwise, viewed from flywheel end.
13Firing order 1-4-7-6-8-5-2-3
14Specific fuel oil consumptiong/kW.h198+3%
15Specific Lube oil consumptiong/kW.h< 1.2g/kW.h
16SmokeRB≤0.3
17NoisedB(A)105
18Starting method Air Rotary valve
19Cooling system Fresh water cooling
20Lubricating system Pressure lubricating
21Fuel oil specification Diesel oil and 720Cst/50℃ HFO
22Lube oil specification CD40 with TBN according HFO
23Piston lifting heightmm2365
24Overall dimensionmm7213×1850×3625mm
25Net weightkg47000
Ⅲ. Alternator specification
No.ItemUnitSpecification
1Alternator Model TFW3800
2Type Brushless generator
3Rated powerkW3500
4Rated voltageV11000
5Rated currentA229.6
6FrequencyHz50
7Power factor 0.8 (lagging)
8Working condition Continuous
9Phase and connection 3-phase
10Voltage regulation method Brushless, self excited
11Insulation Class F
12Protection Class IP23
Ⅳ Cooling tower specification
No.ItemUnitSpecification
1Cooling tower model GBL-150
2Inlet temperature60
3Outlet35
4Base Plane SizemmФ4460×5095
5Blade amount 4
6Fan diametermmФ3400
7Motor fan powerkW11
8Inlet pipe demensionmmDN200
9Outlet pipe demensionmmDN250

The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel


G300 Statinary Generating Sets Main Specification
Model1000GF11250GF31350GF41400GF4
Rated power, KW1000125013501400
Overload , KW1100137514851540
Rated voltage, V400/415/440/3300/6300/10500/13800
Rated current , A        
Frequency , Hz5060506050605060
Power factor0.8 Lagging
Phase3
Diesel engineG6300ZD6G6300ZD8G8300ZD6G6300ZD10G8300ZD10G8300ZD8G8300ZD10G8300ZD8
Rated power, KW11031470147114711765200017652000
Rated rev, rpm500600500600500600500600
Alternator3 phase alternator
voltage fluctuation rate%<0.5<0.5
Frequency fluctuation rate, %<0.5<0.5
Stable voltage regulating rate, %±1.0±1.0
Transient voltage regulating rate, %+20, -15+20, -15
Stable Frequency fluctuation rate, %<3<0.5
Transient frequency regulating rate, %+12, -10
Stablizing time, voltage , S<4
Stablizing time, frequency , S<3
voltage regulating methodautomatic and munual
Frequency regulating methodmanual
starting methodcompressed air
Lubricating methodpressue lubricating
Cooking methodwater cooling
couplingflexible
Overdimension, mm3880*2150*31808470*2360*3060
Weight, Kg300003500038000
G300 Statinary Generating Sets Main Specification
1500GF61600GF51800GF72000GF8
1500160018002000
1650176019802200
400/415/440/3300/6300/10500/13800
        
5060506050605060
0.8 Lagging
3
G8300ZD10G8300ZD8G8300ZD10G8300ZD8G8300ZD8G8300ZD8G8300ZD12G8300ZD8
17652000176520002000200022062000
500600500600600600600600
3 phase alternator
<0.5
<0.5
±1.0
20, -15
<0.5
+20, -15
<5
<4
automatic and munual
manual
compressed air
pressue lubricating
water cooling
flexible
8470*2360*3060
3800042560

Remark


1. the generator voltage and frequency can be selected

2. rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure 100kpa

charge air coolant temperature 25℃

relative humidity 30%

If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position


GN8320 Stationary Generating Sets Main Specification

Model

2400GF

2500GF

Rated power, KW

2400

2500

Overload , KW

2640

2750

Rated voltage, V

400

415

3300

6300

10500

400

415

3300

6300

10500

Rated current , A

4330

4174

525

275

165

4511

4348

547

172

286

Frequency , Hz

50

50

Power factor

0.8 Lagging

0.8 Lagging

Phase

3

3

Diesel engine

GN832000ZD

GN8320ZD

Rated power, KW

2648

2795

Rated rev, rpm

750

750

Alternator

3 phase alternator

voltage fluctuation rate%

±1.0

Frequency fluctuation rate, %

+12, -10

Stable voltage regulating rate, %

3

Transient voltage regulating rate, %

+12, -10

Stable Frequency fluctuation rate, %

4


Transient frequency regulating rate, %

5

Stabilizing time, voltage , S

+1

Stabilizing time, frequency , S

+12, -10

voltage regulating method

automatic and manual

Frequency regulating method

manual

starting method

compressed air

Lubricating method

pressure lubricating

Cooking method

water cooling

coupling

flexible

Overdimension, mm

8950*2570*6050

Weight, Kg

45000


Remark


1. the generator voltage and frequency can be selected

2. rating for the generator set is based on the following standard conditions

air temperature :25℃

total barometric pressure

charge air coolant temperature


relative humidity


If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000

3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position


China 6 X 2MW Electric Power Station Four Stroke Generator Set Pressure Lubrication Method supplier

6 X 2MW Electric Power Station Four Stroke Generator Set Pressure Lubrication Method

Inquiry Cart 0