Diagnostic-tool TLC9803 Portable Cable 24 Hour Heart Monitoring 3 Channels Recordable Dynamic ECG System
Model no.: TLC9803
Recorder Features
* With advanced design and technology, the recorder can work
stably,
dependable and durable.
* Be provided with the capability of anti-jamming and shock-pro.
* Small volume with OLED screen. The resolution is 160*128.
* Be provided with functions of waveform preview, record review and
event
marking.
*Accurate record of the start time of the data sampled owing to the
real time clock
of itself.
*Avoid damage owing to the repeating inserting and pulling out by
using the
inbuilt TF card to storage the data.
*The maximum capability can be 2GB, so the original data can be
saved perfectly
by no compression.
*The average review time of single case can be less than 40 seconds
by using
interface of USB 2.0.
*Record waveform details inextenso by the design of high precision
and sampling
frequency.
*Record the state of pacemaker exactly by higher sampling
frequency.
The features of software
*Quick and accurate analysis system.
*With 3 leads synchro analysis, QRS search can be more exactly.
* There are more than 10 templates as atrial premature beat module,
ventricular premature beat module, long interval module, atrial
flutter module, atrial fibrillation module etc. and multiplicate
User-defined templates could almost identify every kind of
pathologic waveforms.
*Optional main channel.
* Agile and exact "Atrial Fibrillation" analysis.
*The function of pacing analysis could analyse all pacemakers.
* Many pacine modules have been added.
* Any period of single lead or 3-leads ECG can be reviewed at any
time with the
function of fast waveform review and analysis.
* The types of the analysis system of HR variability include five
minutes of short
ECG and one hour or 24-hour of long ECG.
* Print report expediently.
* Perfect function of case management.
* With the function of ST segment analysis and general load of the
disorder of the heart muscle, the physician can judge a disease or
disorder of the heart muscle generally.
*"Sleep breath pause syndrome analysis", the physician could print
sleep asphyxia
analysis report and diagnose.
*"HRT" analysis, when the adjustable function is natural, this
transitory change
will be represented by the form of HRT immediately.
*15."T Wave Alternation" analysis is a important index on judging
and preventing arrhythmia.
Standard
Number of channels | 3 channels |
Sampling rate | 10000Hz |
Sampling accuracy | 12bit |
Recording time | 24 h |
Power | 2 batteries in size 5 |
Interface | USB2.0 |
Scale voltage | 1mV±5% |
Standard Sensitivity | 10mm/mV±5% |
Noise level | ≤30μV |
CMRR | ≥60dB |
Feathers of low frequency | Time constant>3.2s |
Scan speed | 25mm/s±5% |
Enduring polarization voltage | ±300mV |
Least measure signal | 50 µV p-p |
Product safety type | Type B (Internally powered) |
Size | 111mm(L)*60mm(W)*25mm(H) |
Net Weight | 102g (Without battery) |
Accessories
3-lead ECG lead wires *1
ECG electrode *1
USB data line*1
Disk*1
Bag*1
User manual*1
Softdog*1