TG-5600DL Single and dual element color screen Ultrasonic Thickness Gauge
HUATEC TG-5600DL is a portable ultrasonic thickness gauge. Based on
the operating principles of ultrasonic measurement, TG-5600DL is
capable of measuring the thickness of various materials with
accuracy as high as 0.001 millimeters or 0.0001 inches, and widely
used in a variety of thickness measurement applications.
Users can measure the thickness from only one side of the material
being measured, without damaging the workpiece.
TG-5600DL can display thickness readings and A-scans at the same
time, allowing users to check waveforms. The echo display helps
users control the measurement, so that the thickness measurement
range is large, the measurement values are correct, and
material-related errors in measurement can also be avoided. The
B-scan function is used to observe the bottom profile of the
workpiece being measured. The probe moves along the surface of the
workpiece to display the cross-section of the workpiece.
This gauge can be used in manufacturing, metal processing industry,
aerospace, railway transportation, chemical industry, commodity
inspection industry and other testing fields.In addition to
accurately measuring a variety of plates and processed parts,
monitoring a variety of pipes and pressure vessels that in
production equipments to further monitor their thinning levels
after being corroded during use, which is an indispensable tool in
the non-destructive testing industry.
The storage function is optional, according to the different needs
of customers, and built-in large-capacity data logger can store up
to 100,000 thickness measurement values and 400 waveforms. Other
more functions can be optional, such as multi-layer thickness
measurement, ultra-high resolution, large-range thickness
measurement,digital noise reduction and window mode, inner wall
oxide layer, real-time communication, multi-channel and other
options.
Main Measurement Functions
• Most material measurements can be made using single element transducers.
• Measuring thickness range: 0.01 mm ~ 38 m, depending on the material being measured, probe, surface conditions, temperature and selected configuration.
• Determine the sound velocity of an unknown sound velocity material
• High resolution: Regular display resolution is 0.001mm, optional ultra-high resolution can reach 0.0001mm.
• Measurement units: millimeters, inches, microns and mils.
• High temperature measurement: temperatures up to 500°C.
• System default configuration menu: For user convenience, it has been set according to the default conditions for using the probe of the instrument.
• Pause function: allows post-measurement processing operations. Conveniently adjust all parameters to obtain stable measurement data.
• Full-screen waveform display function: increases the echo display area by 20%, giving the operator a large window experience.
• Echo intensity indication: The stronger the echo, the more indicator bars are displayed, especially the digit display, which is more useful.
• Time-based B-scan mode: It is used to observe the bottom profile of the workpiece to be measured.
• Difference/Reduction Rate Mode:The thickness difference relative to the set point is displayed and expressed as a percentage of the reduction rate.
• TDG time-varying gain: The initial pulse or interface echo can be effectively reduced by reducing the initial gain, and the bottom echo of the tested sample can be increased by increasing the maximum gain, which is easy to measure.
• Measurement Mode:Pulse-Echo(P-E),Interface-Echo(I-E),Echo-Echo(E-E),Multiple echo(I-ME),Double echo verification(E-EV)
Standard Configuration
Items | Quantity |
TG-5600DL | 1 |
Probe | 1 |
Cable | 1 |
Rubber Sheath | 1 |
Alkaline Batteries | - |
Couplant Bottle | 1 |
Case | 1 |
Operation Manual | 1 |
Optional accessories
Probes | Cables |
Rubber Sheath | Step Blocks |
Delay Lines | Coupling Agent |
Protective film | Software Options |
Appendix A: Material Velocity
The table lists the propagation velocity of ultrasond in various
common materials. It is only for reference. The actual velocity of
these materials may differ from the velocity in the table for
various reasons, for example, material composition, preferred
orientation of grains, porosity, and temperature etc. Therefore, to
achieve the best measurement accuracy, a sample made of a specific
material should first be tested to confirm the velocity of specific
material.
Table:Material Velocity List
Material | Velocity(m/s) |
Steel 20# | 5891 |
Aluminum | 6320 |
Chromium | 6200 |
Copper | 4660 |
Gold | 3251 |
Iron | 5930 |
Lead | 2160 |
Magnesium | 5806 |
Silver | 3607 |
Titanium | 6098 |
Zinc | 4193 |
Tungsten | 5181 |
Tin | 3320 |
Brass | 4380 |
Grey Cast Iron | 4600 |
Glass | 5766 |
Nylon | 2610 |
Stainless Steel 304 | 5334 |
PVC | 2392 |
Silicon | 9620 |
Quartz Glass | 5655 |
Note:Above table is for reference only. For actual velocity calibration,
refer to 6.2 velocity calibration