HTF-(A) type two-speed axial flow fire high temperature smoke exhaust fan


Product introduction:
HTF series axial flow fire smoke exhaust fan is a fire smoke exhaust product specially designed for high-rise buildings. The fan consists of impeller, housing (including bracket) and motor and other components. This industrial fan can both exhaust and supply air, and has a dual-speed fan for selection. The characteristics of axial flow fans are large air volume (>10000m³/h), low air pressure (<500Pa), high efficiency (70%-90%), small size, and suitable for various explosion-proof places.


Effects of use:
1. Improve air quality
Exhaust fans can effectively remove dirty air, odors and pollutants in confined spaces. Exhaust fans continuously exhaust harmful gases such as carbon monoxide from the space, preventing the accumulation of harmful gases and providing a safe environment.
2. Humidity control
These fans help regulate humidity levels by exhausting humid air from the inside. This reduces the risk of mildew and structural damage in areas susceptible to moisture.
3. Temperature regulation
Exhaust fans assist in temperature control by exhausting hot air from confined spaces, helping to create a cooler and more comfortable environment, avoiding excessive ambient temperatures and equipment shutdowns.


Structural features:
1.Thickened shell:made of high-quality corrosion-resistant Benxi hot-rolled carbon steel plate material, inner layer anti-corrosion and anti-rust paint, outer layer two layers of paint, no rust under long-term outdoor working conditions. Optional materials: 201#, 304#, 316#, stainless steel, etc.
2.Thick bracket:fixed by triangular mechanics, reduces the vibration of the motor during operation, allows the fan to continue to be stable, reduces noise, and can be customized.
3.High-temperature resistant copper motor:directly driven by a dual-speed motor to achieve self-control. The motor bearing is a ball-type lubrication-free type, and the motor power reserve coefficient is 110% to improve safety. It can run safely for more than 30 minutes at a high temperature of 280℃, and can run for a long time at 120℃ without damage.
4.High-temperature resistant impeller:made of high-quality carbon steel stamping processing, high temperature resistance, high strength, large air volume, and not easy to deform. Each different shape of the wing is suitable for different places. The torsion angle, installation angle, width and number of the blades can be designed and calculated according to needs. The wheels and blades can be separated for easy installation. Optional materials include composite materials and aluminum alloys.


Scope of application:
According to different requirements of the building, it can adopt single-speed or multi-speed drive to achieve the purpose of dual-purpose (i.e. common ventilation and high-temperature smoke exhaust during firefighting).
It can be used in gymnasiums, exhibition centers, hotels, office buildings, theaters, auditoriums, hospitals, shopping malls, high-rise residential buildings, basements (parking lots), electrical factories, oil extraction, chemical production, factory warehouses and other factories and mines and large buildings where ventilation and firefighting smoke exhaust are required.


Product parameters and size table:


Product parameter table:

HTF-I-(B) Axial flow single speed fire smoke exhaust fan

Model

(NO)

Power

(KW)

Speed

(r/min)

Flow

(m/h)

Pressure

(Pa)

4429005756-83321212-965
4.55.529006233-1009113212-965
55.5290078016-137801325-853
67.5290016536-22090971-823
711145020861-272421079-9325
815145030019-400901037-918
918.5145038740-470621037-949
1022145043195-57321202-1169
1130145051442-637301196-922
123096048796-74477117-901
133096060256-949081045-721
153796064064-1234051219-689

HTF-II-(B) Axial flow two-speed fire smoke exhaust fan

Model

(NO)

Power

(KW)

Speed

(r/min)

Flow

(m/h)

Pressure

(Pa)

53.1/0.829007000-10088744-523
14503501-5044193-1 30
65.9/1.4290013552-165231016-523
14506776-8261251-130
79.5/3.1145019417-25037747-626
96012855-16576327-274
89.5/3.145026713-322 68667-616
96017686--21360287-270
912/445028 357- 34413862-577
96018707-22784377-252
1012/445035944-46910790-646
96024666-21070347-283
1115.5/5.1145049808-52942698-595
96037725-39706397-169
1217/8.596057156-64455759-640
72044479-48341427-360
1317/8.596057542-76722828-616
72043156-57542466-347
1521/1196078091-96329492-434
72058569-72247267-2259

Product size table:


HTF-B type axial flow fire smoke exhaust fan appearance and installation dimensions

Moder

(No.)

ΦD1ΦD2ΦD3L1L2L3L4H4-od1n-0 d2Weight(kg)
44104454955004374003002654-φ126-φ935
4.54605105665004374503502904-φ126-φ940
55105606106005375004003154-φ1412-φ1145
66106557106505876005003854-φ1412-Φ1160
77107608107006377006004354-Φ1412-φ1380
88108609167506878007004854-Φ112-φ13100
991096010159008359008005304-φ1912-φ13130
1010101070113690083510009005854-φ1912-φ17180
111110117012361000935110010006354-φ1914-Φ17200
121210127013361050985120011006854-φ1914-φ17230
1313101370143612001150130012007504-φ2116-φ17280
1515101570163612001150150015008304-φ2516-φ17400

Packing and Shipping:
Product Packaging:
Each smoke exhaust fan is securely wrapped with protective materials and placed in a sturdy carton to prevent any damage during transportation and ensure safe delivery. .

Shipping:
We provide fast and reliable shipping services for all smoke exhaust fan orders. Once your order is confirmed, our team will quickly process and ship it in time according to your needs. You will receive a tracking number so that you can check the delivery status of your package at any time.


FAQ:

Q: Do you have independent R&D capabilities?
A: We have a professional R&D team and regularly collect feedback from each customer for product improvement and new product development. If the required specifications are not in the parameter table, please let us know your requirements and we will provide you with a satisfactory design solution.


Q: How many years is your warranty period?
A: We can provide a 2-year warranty.


Q: Can we place a trial order first to test the quality?
A: Yes, very welcome.


Q: What is your payment method?
A: T/T, Western Union, L/C and PayPal. The specific method can be negotiated.


Q: How long is your delivery cycle?
A: It depends on the order quantity and the season you place the order. Normally, we can ship small batches within 10-15 working days and large batches within 30 days.


Q: Do you have a complete firefighting equipment?
A: Yes. In addition to various models of fans, we also have a variety of complete fire protection equipment, including but not limited to fire alarm systems, smoke exhaust systems, emergency evacuation lighting systems, gas fire extinguishing systems, fire evacuation broadcasting systems, etc.


Q: Can you design a complete fire protection system for me?
A: Yes. We have professional engineers who can design the specifications and quantities of products according to your needs. If you know little about the volume or area of your warehouse, factory or workshop, such as length, width, height, please be sure to contact us in time.


China High Temperature Axial Flow Fire Smoke Exhaust Fan 280℃ HTF Series supplier

High Temperature Axial Flow Fire Smoke Exhaust Fan 280℃ HTF Series

Inquiry Cart 0