Polymeric Metal Oxide Surge Arrester for Substation / AC - DC Converters / Power Distribution Units

Brand Name:YONGDE
Certification:ISO9001/KEMA
Model Number:YH5W5-24
Minimum Order Quantity:1pcs
Delivery Time:21days per container
Payment Terms:T/T or western Union or L/C or PayPal
Contact Now

Add to Cart

Verified Supplier
Location: Hangzhou Zhejiang China
Address: Yinghu Economy Developing Zone, Fuyang Hangzhou City, Zhejiang Province, China
Supplier`s last login times: within 42 hours
Product Details Company Profile
Product Details

Polymeric Metal Oxide Surge Protector , Station Metal Oxide Lightning Protector


Description:


YongDe Surge Arresters can be applied to a variety of systems including substation equipment, AC-DC converters, railway power system and power distribution units ranging from 0.25kV to 765kV systems. These surge arresters demonstrate excellent protection properties. YongDe surge arresters incorporate YNR elements (YongDe Non-linear Resistor ZnO Elements) with superior non-linear voltage-current characteristics, high quality and reliability. Metal oxide type surge arresters offer such special features inherent in the gap-less structure, such as a quick response to surge voltage, high energy dissipation capability, safe operation, compactness / lightweight and freedom from pollution.


Features:


1. Compact and Lightweight

2. Extremely Safe Pressure Relief Performance

3. Superior Performance against Environmental Contamination

4. Directly Molded Structure

5. Compliance with International Standards(IEC60099-4)

6. Simple Support Structure

7. Manufactured at Advanced ISO-9001 certified facilities


Specifications:


TypeYH5W5-24/64.3
Rated voltage---------kV24
MOCV ----------------kV19.5
Nominal Current-------kV5
Residual voltage of steep impulse----at 5kA(kV)69.5
8/20µS Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV)64.3
Residual voltage of switching impulse current kV (peak value)----at 1kA (kV)/
1mA D.C reference voltage (kV)34
Line discharge level1
2mS long duration impulse current A250
4/10µS High current impulse kA65
Lightning impulse withstand kV125
Power frequency voltage withstand(dry/wet)kV50
0.1S TOV--------------kV28.8
1S TOV----------------kV27.6
10S TOV---------------kV26.4
1200S TOV-------------kV24
Creepage distance ----mm824
Material employed in series non-linear resistorZinc Oxide
China Polymeric Metal Oxide Surge Arrester for Substation / AC - DC Converters / Power Distribution Units supplier

Polymeric Metal Oxide Surge Arrester for Substation / AC - DC Converters / Power Distribution Units

Inquiry Cart 0