Pure Sine Wave High Frequency ATM UPS With Battery Inside , High Power
Applications
Outdoor UPS This product is designed for communications ,
electricity, railways , airports, defense and other departments
designed to eliminate the impact of the grid, surges, interference
and other adverse effects of the fall and the communication device
caused . When using a unique anti-irrigation noise suppression
technology , the battery pack is 220VAC sine wave inverters , will
not affect the operation of other communication devices are the
ideal communication device " protection of God ."
Features
■ Outdoor Design : Suitable for harsh outdoor environments , the whole rugged sealed , waterproof, dustproof, heat insulation , anti-theft , anti- corrosion, moisture , and a variety of features , ease of installation , and maintenance.
■ Meet the communication AC and DC power supply system standards.
■ AC DC DC AC and use double conversion technology and on-line double conversion technology
■ Excellent overload capacity , no longer need to worry about frequent conversion to bypass .
■ Perfect protection function , whether it is a short circuit , low battery voltage , overheating , the system will automatically protected.
■ Efficient filtering synchronization circuit is fully compatible with the generator .
■ With RS232 interface , the software can be used with a computer monitor UPS operation
Performance indicators
model | HW10G | HW20G | HW30 | HW60 | |||
rated capacity | (VA) | 1000 | 2000 | 3000 | 6000 | ||
Output | voltage | 220Vac±2%(The inverter state) | 220Vac±1% | ||||
Frequency | 50Hz±0.1Hz(The inverter state) | 50Hz±0.5Hz | |||||
Waveform | Pure Sine Wave | ||||||
THD | ≤3% (linear load) | ||||||
power factor | 0.8 | 0.8 | |||||
efficiency ( full load) | >85% | >85% | |||||
Input | Frequency | 45Hz~55Hz( automatic lock phase) | 50Hz±5% | ||||
voltage | 160Vac~275Vac | 165Vac~ 275Vac | |||||
DC voltage input | 36Vdc | 96Vdc | 192Vdc | ||||
TRANSFER TIME | Mains fail or recover | Zero | Zero | ||||
Noise | Distance (1 m) | <50dB(A) | <55dB(A) | ||||
Alarm device | Battery Refresh | audio and video alarm | |||||
UPS abnormal | Continuously Sounding | switch to bypass | |||||
Automatically start | Undervoltage shut down output, after a mains immediately when the input to the output automatically | ||||||
DC start | yes | ||||||
Software settings | Auto Start-up | yes | |||||
Protection functions | overload | 100%~125% load for 60mins | 100~125% Maintain 60 seconds turn bypass, >125%Immediately urn the bypass | ||||
125%~150%load for30 mins | |||||||
150%Immediately turn the bypass | |||||||
| Inverter lockou t(Shutdown)protection | At the same time to cut off the inverter output and the bypass output | |||||
| turn bypass | ||||||
turn bypass | |||||||
overvoltage | |||||||
Battery over discharge protection | Battery over discharge autom atically shut down output | ||||||
EMC | Meet GB 9254 | ||||||
Communication | backup powe,low cellvoltage, Remote control grading machine shutdown and real-time monitoring of communication | ||||||
Working Environment | Temperature | -20~50℃ | |||||
Humidity | 0~95%(No con densation) |