IEC60112 Flammability Testing Equipment Leakage Tracking Tester 0~600V Testing Voltage Button Operation

Brand Name:HongCe
Certification:Calibration certificate (cost additional)
Model Number:LT-2
Minimum Order Quantity:1 set
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

IEC60112 Flammability Testing Equipment Leakage Tracking Tester 0~600V Testing Voltage, Button Operation


Standard:IEC60112-2009, UL746A, IEC60335-1, IEC60598-1 and ASTM D3638-92. Flammability Testing Equipment

Application:It is used to evaluate the tracking resistance performance of solid insulating material surface under the combined influence of electric field and humid or contaminate medium. In a word, this device is used to measure the comparative tracking index (CTI) and proof tracking index (PTI). Flammability Testing Equipment

Test sample:Lighting equipment, low-voltage electrical appliances, household electrical appliances, machine tools, electrical appliances, electric motors, electric tools, electronic instruments, electrical instruments, information technology equipment, insulation materials, engineering plastics, electrical connectors, accessories industry.

Feature: The working principle of the leakage tracking test(tracking index testing) is that the conducting liquid (0.1%NH 4 CL) of required volume in the required height (35mm ) and required time (30s) drops with the voltage between the platinum electrodes (2mm× 5mm )on the surface of solid insulating material. Thus the users evaluate the tracking resistance performance of solid insulating material surface under the combined influence of electric field and humid or contaminate medium. In a word, this device is used to measure the comparative tracking index (CTI) and proof tracking index (PTI). Flammability Testing Equipment


Parameters:

ParametersModelLT-2(0.5m³)
Working voltage220V/50Hz,1KVA
Control operation modeElectrical control, button operation
Testing voltage0~600V adjustable,precision 1.5%
Timing device9999X0.1S
ElectrodeMaterial:Platinum electrode and brass connecting rod
Size:(5±0.1)×(2±0.1)×(≥12)mm,30°slant,Tip rounding:R0.1mm
Relative position of electrodeIncluded angle:60°±5°, distance is 4±0.1mm
Electrode pressure1.00N±0.05N(digital display)
Dripping liquidThe interval time of dropping liquid:30±5S,digital display,can be preset
Height:35±5mm
The number of drips:0-9999 times,can be preset, the volume size of the dripping liquid is controlled by the imported micro pump within 50 ~ 45 drips /cm³
Test liquid resistanceA liquid 0.1%NH4Cl,3.95±0.05Ωm, B liquid 1.7±0.05Ωm
Time-delay circuit2±0.1S (in 0.5A or larger current)
Short-circuit pressure drop1±0.1A 1%,pressure drop 8% MAX
Wind speed0.2m/s
Environmental requirement0~40℃,relative humidity≤80%,in the place of no obvious vibration and corrosive gas