Add to Cart
IEC 60884-1 Plug Socket Tester Load Box Load Cabinet 3 Stations
Standard: IEC 60884-1 2013 clause 20 and 21, IEC 60950-1, IEC 60598-1, IEC61058-1, IEC60669-1 and so on
Application: This device is used for household and similar purpose fixed electrical appliance switch, plug and socket, coupler for on-off ability, breaking capacity and normal operation life test. Plug Socket Tester
Test sample: Household or similar purpose switches, plugs, sockets
Feature: This device is with blue framework and gray cover. The top of this apparatus is the operation control panel on which there are switches for controlling power supply, for the electric capacity conversion and for the load type conversion. There are also the displaying meters of connecting current and voltage as well as power, the buttons of start and stop, alarm, the status indicator light and so on. Below are the according knobs for output voltage adjustment, for current adjustment and for inductance adjustment. There are three stations, each station has the function of resistive, inductive and capacitive Load test. The kind of load test can be chosen by the transferring switch. The load box inside is cooled by the strong wind convection. There are terminals below the load box through which the load box can be connected with the switch and plug-socket endurance tester using the wire. During the process of test, the equipment outputs the current and voltage as well as power. Plug Socket Tester
Technical Parameters
No | Item | Parameter |
1 | Power Supply | AC380, 50Hz. |
2 | Voltage V | 0~300V, accuracy: ±0.5% |
3 | Current A | 0~30A, accuracy: ±0.5% |
4 | Power KW | 0~10KW, accuracy: ±0.5% |
5 | Power Factor | 0.3~0.98, accuracy: ±0.5% |
6 | Load Selection | Resistive, Inductive and Capacitive load three in one, switchable |
7 | Capacitance Selection | 70uf, 140uf, 73uf optional |
8 | Output Mode | Each power, Interval power optional |
9 | Count/Preset | 0~999999 times, can be preset |
10 | Load power capacity | 3*10KVA |
11 | Max. of the output current | 30A,when it exceeds 32A, it stopped automatically |
12 | Max. of the output voltage | 300V, when it exceeds 305V, it stopped automatically |
13 | Atmospheric pressure | 80~106kpa |
14 | Ambient temperature | 5~40°C Plug Socket Tester |
15 | Relative humidity | (20~90)%RH |
16 | Use environment | Requires no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive, no corrosive gases, needs good heat dissipation place |
17 | Stations | 3 |
Picture for reference: