IEC60598-2-8 Impact Tester For Handlamps With 400mm And 1000 Mm Impact Height

Brand Name:HongCe
Certification:Calibration Certificate(cost additional)
Model Number:HL-1
Minimum Order Quantity:1 set
Delivery Time:25 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

IEC60598-2-8 Impact Tester for Handlamps With 400mm And 1000 mm Impact Height


Product introduction: Light Testing Equipment

This apparatus confirms to the standard requirement of IEC60598-2-8:2007 clause 8.6.6.2 and Figure 1. It is used to check the mechanical strength of handlamps. This device should be mounted on a solid wall vertically of brick, stone, concrete or similar material. This is a manual apparatus.

Application:It is used to test the impact resistance of hand lamps. Light Testing Equipment


Parameters:

1. Bar size: 40mm×40mm×5mm right-angle section with the corner rounded to a radius of 5mm.

2. Impact height: 400mm/1000mm

3. External dimensions: 1250mm×1500mm×200mm

4. Material:Stainless steel and aluminum Light Testing Equipment


ModelHL-1
Product nameImpact Tester for Handlamps
Bar size Light Testing Equipment40mm×40mm×5mm right-angle section with the corner rounded to a radius of 5mm.
Impact height400mm/1000mm
External dimensions1250mm×1500mm×200mm
MaterialStainless steel and aluminum

Test procedure:

The handlamp, without lamp, is suspended by its flexible cable or cord so that the point "a", indicated in Figure 1 , rests against the corner of the bar, the point of suspension being 400 mm above the bar. It is then drawn away from the bar in a plane perpendicular to the wall until the cable or cord is horizontal.

The sample is allowed to fall against the bar three times in this way. It is then suspended so that the impact is at the point "b", and caused to fall similarly three times, followed by three falls against the point "c".

After this first test, the sample shall show no damage impairing its safety or further use. The whole of the above test is then repeated but with the point of suspension 1 m above the bar. Light Testing Equipment

After this second test, the sample shall show no damage impairing its safety or further use.

The means protecting the lamp against damage shall not have loosened, even if it has become deformed. Breakage of the protective glass of translucent cover, if any, is neglected, if it is not the sole means protecting the lamp against damage.


China IEC60598-2-8 Impact Tester For Handlamps With 400mm And 1000 Mm Impact Height supplier

IEC60598-2-8 Impact Tester For Handlamps With 400mm And 1000 Mm Impact Height

Inquiry Cart 0