Product Details

IEC60695 Horizontal And Vertical Flame Tester - 50W And 500W


IEC60695-11-10

7.2 Material testing

The results of tests carried out on test specimens of different colour, thickness, density, molecular mass, anisotropic direction and type, or with different additives or fillers/reinforcements can vary.

Test specimens with extremes of density, melt flows and filler/reinforcement content may be provided and considered representative of the range if the test results yield the same flame test classification. If the test results do not yield the same flame test classification for all test specimens representing the range, evaluation shall be limited to the materials with the extremes of density, melt flows and filler/reinforcement contents tested. In addition, test specimens with intermediate density, melt flows, and filler/reinforcement content shall be tested to determine the representative range for each flame classification.

Uncoloured test specimens and test specimens with the highest level of organic and inorganic pigment loading by weight are considered representative of the colour range, if the test results yield the same flame test classification. When certain pigments are known to affect flammability characteristics, the test specimens containing those pigments shall also be tested.

Test specimens which shall be tested are those that

a) contain no colouring,

b) contain the highest level of organic pigments,

c) contain the highest level of inorganic pigments,

d) contain pigments which are known to adversely affect flammability characteristics.


Standard:UL94,IEC60695-11-2, IEC60695-11-3, IEC60695-11-4, IEC60695-11-10, IEC60695-11-20.

Application:It simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method. Flammability Testing Equipment

Test sample:It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method. Flammability Testing Equipment

Feature: This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, stainless steel of box full, large observation window, imported digital indicator of high precision, nice appearance. And they gather a number of advantages of similar products home and abroad. Flammability Testing Equipment


Parameters:

ParametersModelHVF-1HVF-2HVF-3(Touch screen)
Working voltage220V/50Hz220V/50Hz220V/50Hz
Power/grade50W or 500W50W and 500W double power switching50W and 500W double power switching
Control operation modeElectrical control, button operationElectrical control, button operationPLC control, 7 inch color touch screen operation, with infrared remote control
Blast burner standardIEC60695-11-3/IEC60695-11-4/10,UL94,inner diameter:Φ9.5±0.3mm,length:100mm,made of brass
Gas pressure0.1MPa
Gas flow50W:105±5ml/min or 18±1mm;500W:965±30ml/min or 117±3 mm,flow meter adjustment
U type pressure gauge back pressure water column height50W:10mm; 500W:125±5 mm
Test angle50W: 0°,45°; 500W: 20°
Burning time0-9999X0.1S Can be preset
Burning times0-9999 times,Can be preset Flammability Testing Equipment
Residual flame/Residual glow0-9999X0.1S Can be displayed
Test flame calibrationTemperature measuring copper head:50W:Ф5.5mm±0.01mm,weight before drilling 1.76 ± 0 .01 g;500W:Ф9mm±0.01mm,weight before drilling 10 ± 0 .05g
Thermocouple:The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple,temperature resistance 1100°
Distance between the bunsen burner port to temperature measuring copper block:50W: 10±1 mm; 500W: 55±1 mm
Flame height:50W: 20±2mm(there is no internal and external flame); 500W: Inner flame:40±2mm,Outer flame:125±10mm
Temperature rise time from100±2°to 700°±3°50W: 44±2S; 500W: 54±2S
LightingEquip with lighting in the test chamber, with control
Test chamber and dimension> 0.75 cube,black inwall,with exhaust fan, dimension:1100*550*1200mm, 140kg