Home /Cable Manufacturing Equipment /

IEC60332-1 Flammability Testing Equipment For Single Insulated Wire Or Cable Burner Tilt 45°

IEC60332-1 Flammability Testing Equipment For Single Insulated Wire Or Cable Burner Tilt 45°

Brand Name:HongCe
Certification:Calibration certificate(cost additional)
Model Number:VF-1
Minimum Order Quantity:1 set
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 202, Building 4-2, No. 539, Shibei Industrial Road, Dashi Street, Panyu District, Guangzhou, Guangdong
Supplier`s last login times: within 15 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

IEC60332-1 Flammability Testing Equipment For Single Insulated Wire or Cable Burner Tilt 45°


Purpose:
When the wire and cable products are short circuited or exposed to fire, the insulation or sheath may burn. In many occasions (coal mines, ships, subways, shopping malls and other public places) where strict fire prevention is required, the flame should not spread in case of combustion, but extinguish itself in a certain period of time and a certain length, which is called non flame retardancy. In some cases, if the product does not have this function, it will cause extremely serious personal injury and property losses.
Therefore, in the production process, PVC, chloroprene rubber and butylamine PVC composites are widely used as insulation and sheath materials for products with non flame retardancy. When these materials are burned, chlorine will be released to play a flame retardant role. Sometimes in order to enhance the effect of flame retardant, some flame retardant is added.

Flammability Testing Equipment

Standard: IEC60332-1-1:2004,IEC60332-1-2:2004,IEC60332-1-3:2004, IEC 60950-1,BS EN 60950-1,BS 7002, UL746A,IEC60947.1, IEC730.1. Flammability Testing Equipment

Application:Suitable for vertical burning test of single cable or optical cable products, determine the combustion characteristics of insulating materials.

Test sample:Single cable or optical cable products.

Feature:Using integral intake automatic ignition system, combustion time delay only 0.1s to ensure that the full combustion of the gas.


Parameters:

Working voltage220V/50Hz
Control operation modeElectrical control, button operation
Blast burnerBurner opening:Φ7±0.05mm,made of brass
Gas flow and gas categoryMixture gas:650±30mL/min propane;10±0.5L/min air,Dual flow meter adjustment
Burning time9999X0.1S
Burning angleTilt 45°±2°,Adjustable

Test flame calibration


Flammability Testing Equipment

Temperature measuring copper head:500W:Ф9mm±0.01mm,weight before drilling:10 ± 0 .05g
Thermocouple:The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple,temperature resistance 1100°
Distance between the bunsen burner port to temperature measuring copper block:95 mm
Flame height:Inner flame:55±5mm,Outer flame:180±10mm
Temperature rise time from 100±5°C to 700°±3°C 45±5s
Combustion chamberWDH=300×450×1200±25mm
Gas>95% propane or coal gas
Test sampleLength:600±25mm, distance from the bottom:50mm
Fixed horizontal support of the sample2, distance:550mm
DimensionWDH=700×450×1350mm, weight about 90kg

China IEC60332-1 Flammability Testing Equipment For Single Insulated Wire Or Cable Burner Tilt 45° supplier

IEC60332-1 Flammability Testing Equipment For Single Insulated Wire Or Cable Burner Tilt 45°

Inquiry Cart 0