Household Plug Socket Tester For The Temperature Rise Test Of IEC60884-1 Clause 19 Figure 44 high - precision 6 stations

Brand Name:HongCe
Certification:Third part calibration certificate(cost additional)
Model Number:HC9910A
Minimum Order Quantity:1 Set
Delivery Time:30 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

Device For The Temperature Rise Test Of IEC60884-1 Clause 19 Figure 44 high-precision 6 stations


Standard:
IEC60884-1 Plugs and socket-outlets for household and similar purposes – Part 1:General requirements clause 19 and figure 44.

Application:
It is mainly used to test the plug device and its accessories around, such as dimmers, fuses, switches, power regulators, etc., and it cannot reach excessive temperatures during normal use.

Test sample:
Household plugs and sockets.

Features:
This device adopts a high-precision digital meter, sensor signal input with 6 work stations, over-temperature and overload protection with voice prompts, strong applicability and stable performance.

Parameter:

ItemParameters
Test station6
Test current0-125A adjustable
Test voltageLess than 12V
Timer0-9999s, adjustable, digital display
Temperature instruments0-150°C, digital display
Power supply220V, 50HZ
Test objectPlug pin
StandardIEC60884-1 Fig 44 Clause 19


Connecting wire and current matching table:

Sizes of the wire (single copper core)Max. Load Current
1.5mm²20A
2.5mm²28A
4mm²38A
6mm²48A
10mm²65A
16mm²88A
25mm²113A
50mm²142A
70mm²171A
95mm²218A
120mm²265A
150mm²305A
185mm²355A
240mm²410A
300mm²490A
400mm²560A
500mm²650A
630mm²750A
2.5mm²880A
800mm²1100A