Two Vacuum Chamber Helium Leak Test System for Automotive Dry Filter Less Than 1.5g/year

Brand Name:HongCe
Certification:Third party calibration (Cost additional)
Model Number:HJAU019
Minimum Order Quantity:1 set
Delivery Time:90 days
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: No.6-39, Yaogu Farm, Shibi No.3 Village, Shibi Street, Panyu District, Guangzhou
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details

Two Vacuum Chamber Helium Leak Test System for Automotive Dry Filter


This helium leak test system is designed according to the basic principle of helium leak detection, helium is used as the tracer gas, helium is filled into the workpiece in the vacuum chamber, and then the helium leak detector can accurately and quickly judge the leakage of the workpiece.


Technical Parameters


Name of ProductsDry Filter
Vacuum Chamber SizeL 700mm * W 450mm * H 230mm
Vacuum Chamber Quantity2
High Pressure Gas for Gross Leak4 Mpa(Downward adjustable)
Tracer GasHelium
Reject PointLeakage Rate <1.5g/year
Helium Pressure for Indicating Leakage3.6Mpa(Downward adjustable)
Test Cycle120 chamber/hour

Vacuum chamber integrated sealed pipes and joints


(1) each chamber has 6 pieces of evacuating & filling pipes (including 3 sets of joints)
(2) each pipe is individually controlled


Work process description:


The system has 2 vacuum chamber, the 2 chambers work linkage, operator place the products into the vacuum chambers and connect them with quick joints, after that press the door-close buttons to close the doors, the detection cycle starts. There are grating protectors on both sides of the vacuum doors, when operator close the doors, please ensure that there is no object in the door area to influence door movements.

Once one of the chamber door is closed, the detection cycle of this chamber begins. At this point, the operator can go to the other chamber for operation.


Test Cycle Process:


- Manual seal Product with fixture inside of Test Chamber.
- Closure of the Chamber.
- Evacuation of the Chamber to a value of vacuum suitable for Leak Test with Mass Spectrometer. During the evacuation of the Chamber, the system will run the following Tests on the Products:
- Pressure decay to reveal Gross Leaks;
- Pressure discharge and Products evacuation;
- Reaching a vacuum value suitable for transfer, that is to put the mass spectrometer in communication with the Test Chamber.
- Reading of background, which is the residual Helium in the Test Chamber.
- Pressurization of Products with Helium.
- Leak test with Mass Spectrometer.
- Ventilation of the Test Chamber (return to atmospheric pressure), helium recovery from the products to a specific pressure (depend on chosen parameters and final evacuation of the Products).
- Opening of the Chamber
- Manual unloads of Products.



China Two Vacuum Chamber Helium Leak Test System for Automotive Dry Filter Less Than 1.5g/year supplier