Add to Cart
Electric Wire Horizontal-vertical Flame Apparatus
Product information:
The device is designed and manufactured in accordance with UL1581 standards and related requirements. It is applicable for the finished wire and cable, or soft-line to do 1060 vertical combustion and FT1 test, 1061 cable combustion test, 1080VW-1(vertical specimen) combustion test, 1090 electric wire horizontal specimen combustion test and 1100 horizontal specimen/ FT2 combustion specimen. The testing purpose is to evaluate the spreading flame capacity of electric wire or soft-line when they are on fire.
Standard: UL1581 Reference standard for electrical wires,cables, and
flexible cords.
Application:It is applicable for the finished wire and cable, or soft-line to
do 1060 vertical combustion and FT1 test, 1061 cable combustion
test, 1080VW-1(vertical specimen) combustion test, 1090 electric
wire horizontal specimen combustion test and 1100 horizontal
specimen/ FT2 combustion specimen. The testing purpose is to
evaluate the spreading flame capacity of electric wire or soft-line
when they are on fire.
Test sample:Rubber insulated cables, thermoplastic insulating material for
wires and cables, cords and service cable.
Feature:
1.Using integral intake automatic ignition system, combustion time
delay only 0.1s to ensure that the full combustion of the gas.
2.Using PLC intelligent control system, touch screen operation
interface, and with remote control wireless sensor remote
operation, so that to make the record is more accurate.
3.The blast burner is in accordance with ANSI/ASTM D 5025 standard
manufacturing Bunsen, precise and durable
4.The imported Omega armoured K type thermocouple and U type
differential pressure gauge
5.Black background, multifunctional flame gauges, so that to make
the flame adjustment work becomes simple, stainless steel box,
large observation window easy operation.
Technical parameters:
Timing device | 9999X0.1s |
Combustion angle | 0°,20° |
Flame standard | ANSI/ASTM D 5207 & UL 1581 |
Blast burner standard | ANSI/ASTM D 5025 |
Temperature measurement | MAX 1050°C |
Gas flow | ml/min ±0.1% |
Thermocouple | NiCrφ0.5 armour ±0.1% |
Flame test | 225W/50mm(16.5mm)/84±2S 405 ±10mL/min& 45±5 mm water 500W/125mm(40mm)/54±2S A:965 ±30mL/min&125±25 mm water B:385 ±15mL/min&552±100 mm water C:300 ±10mL/ min&600±125 mm water |
Temperature controller | 16A/D ±0.05% |
Copper billet weight | 10 ± 0 .05 g (before drill) |
Gas category | Methane purity>98%(equipped by the user) |
Dimension | Combustion box:2*2*1.207(M),internal capacity is larger than 4 cube |
It is equipped with:
Methane reducing valve:1/2 inches pipe thread,14 pitch of
thread,sinistrogyration direction;
lame height gauge
Degreasing cotton for testing.