3 Pole 10000A Earth Leakage Mini Circuit Breaker Overload Protection


The ELCB is applied to the circuit of AC 50Hz with rated voltage up to 400V, rated current up to 50A, power supply neutral point earthing. It's mainly used to protect person from getting an electric shock and protect the building′s circuit devices from over current, it also can protect the earthing fault.

The ELCB is according with IEC61009-1:1991, GB16917.1-1997 standard.


Specifications:

Technology Specification & Electrical Specification
Electric standardIEC61009; GB 16917.0
Trip timeNon-time delay; Minimal 10ms time delay
Rated voltage230V; 50HZ 230V/400V
Rated surplus operating current10; 30; 100; 300mA
Selection grade3
Rated braking capacity10kA
Rated current6-63A
Tripping characterB, C, D characteristic curve
Maximum connected fuse100A gL(> 10kA)
Environment capabilityAccording to the IEC 1008 standard
Case protection gradeIP40 after installation
Electric lifeNot less than 4000 times of breaking and closing
Mechanical lifeNot less than 2000 times of breaking and closing
Mechanical Parameter
Installation modeInstallation at the DIN guide rail of 35mm
Terminal block capacityGeneratrix thickness 0.8-2mm

Normal working condition and installation condition:


1. The maximum ambient temperature should be -5°C≤T≤40°C,average temperature should be ≤35°C

at 24h


2.The altitude of installation place should not exceed 2000m.


3. The relative humidity should not exceed 50% at 40°C, it permits higher relative humidity when at a higher temperature, the average maximum relative humidity should not exceed 90% at maximum humidity month, and this month′s average minimum temperature does not exceed +25°C, and should take consideration of the condensation on the product′s surface for temperature change.


4. Pollution grade: 2


5. Installation type: 1,2


6. The external magnetic field of installation place should not exceed 5 times of earth magnetic field.


7. The mini circuit breaker is installed by standard mounting rail.


8. The mini circuit breaker is upright installation, knob upwards is switch on position


9. The installation place should be without obviously impact and libration.


Tripping Curve: