GJB Standard PLC Control Environmental Test Chamber

Brand Name:Gaoxin
Certification:ISO 2008
Model Number:GX-3000-CH
Minimum Order Quantity:1set
Delivery Time:15 working days
Payment Terms:FOB Shenzhen, L/C, T/T, Western Union
Contact Now

Add to Cart

Active Member
Location: Dongguan Guangdong China
Address: No.7, Shengfeng Road 523039, Xinhe Industrial Park, Wanjiang, Dongguan, Guangdong, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

PLC Control Environmental Test Chamber High Low Temperature Rapid Heating Colding Impact Tester



1. Quick Details

Alternative name

Rapid Temperature Change Test Chamber

Function

Testing material structure or composite materials in instant and
continuous temperature changing environment, check the chemical
and physical damage.
Provides basis and reference to improve quality of products

Type

High termperature zone, low temperature zone, test zone

Weight

180kg

Internal space

1510mm*1730mm*1660mm

Corresponding test standard

GJB150, GJB360, GBJ367, GB/T5170, GB10592



2. Description

Thermal shock tester also is named rapid temperature changing tester or thermal cycling chamber.
The tester is used for testing material structure or composite materials.
The specimen will be exposed to continuous and instant changing circulation of extreme high and low
temperature.
Then check the chemical change and physical damage of the specimen caused by instant temperature
change.
The tester is applied to mental, plastics, rubber, electronics. The test can provides basis and reference
to improve quality of products.
The tester is divided into high temperature zone, low temperature, and test tank.
The specimen shall be still, while the tester employ special coldness and heat storage system. The cold
and hot wind will be switched and channeled to the test tank in moment, and finish the test when get the
set time.


3. Features

a. The tester is used for test chemical change and physical damage of specimen after suffering

instant extreme high and low temperature change.

b. The tester is divided three zone.

c. Widely usage.


4. Specifications

Model

GX-3000-CH

Temperature range of test tank

-40℃~+150℃

Preheating range of high temperature tank

+60℃~+150℃ (30min, room temperature +
10~+30℃)

Precooling range of low temperature tank

-10℃~-40℃

Cooling time for low temperature tank

About 80min from +20℃ to -40℃ (room temperature
+10~+30℃)

Temperature Fluctuation

±2.0℃

Temperature uniformity

±3.0℃

Temperature shock recovery time

Within 5min


China GJB Standard PLC Control Environmental Test Chamber supplier