Add to Cart
IP54 RS485 Intensive Use Toll Barrier Gate For Highway Car Control
Functions & Features
1. Manual release
2. Machine core with compression spring, effectively avoids the
accidents caused by spring breaking
3. Die-casting aluminum alloy motor, precision and good at thermal
radiating
4. Motor cooling fan, solving the problem of heat-protection
5. Double safety limit switches (photoelectricity limit
switch/motor memory sensor)
6. Reversing on obstacle
7. Auto-closing
8. Support the INFRARER PHTOCELL for anti-bumping function
(optional)
9. Support the external and internal VEHICLE LOOP DETECTOR
(optional)
10. Traffic light interface
11. Wire control (switch signal)/ Remote control (418MHZ)
12. RS485 communication module (optional)
Specifications
Model | WST115B |
Working Temperature | -40℃~+75℃ |
Voltage | 220V±10%, 110V±10%, 50/60HZ |
Rated power | 80W |
Relative humidity | ≤90% |
Remote control distance | ≥30m |
Net weight | 48kgs |
Speed | 1S,1.8S,3S, 6S |
Max boom length | 6 meters |
Motor Rotational speed | 1400rmp |
Protection Degree | IP44 |
Parking & Shipping:
Packing list | |||
Name | Specifications | Quantity | Remarks |
Machine core | Good in working | 1 | Main part |
Barrier arm | Straight, folding or fence arm | 1 | Optional |
Boom press board | 1 | Fixing the boom | |
Self-tapoing screw | ST4*16 | Fixing the boom | |
Self-tapoing screw | st3*10 | 4 | Fixing the boom |
Supporting pole | 1 | Fupporting the boom | |
Expanion bolt | M16*150 | 4 | Fixing the case |
Hexagonal Inner Screw | M8*35 | 4 | fixing the case |
Clutch key | 1 | clutch device | |
Case Key | 2 | for case and cover locking | |
Balance spring | According to length of barrier arm | 1 | for sapre usage |
Remote emitter | less than 30m is available | 1 | For remote control |
Remote conrol handles | less than 30m is available | 2 | For remote control |
Instruction | in English | 1 | For reference |
RS485 interface | 1 | Optional | |
Disc | 1 | Optional | |
Communication Mould | 1 | Optional | |
Cover head | 1 | 3 years without fading | |
Expanion nut | M8 | 4 | Fixing the supporting pole |
Communication with customers
1) Q: Connected power and press open/close button but boom barrier
gate no action?
A | Reason | Solution |
1 | Fuse blown | Check fuse and power in controller |
2 | Battery of remote control powered off | Change a new one |
3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box |
4 | Same frequency interference | Check photocell and loop detector |
2) Q:Connected power and press open/close button, boom barrier gate
will move but even when it is at right position, the motor still
running and not stop?
A | Reason | Solution |
1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position |
2 | Main controller failure | Change a new one |
3) Q: Motor running but boom barrier gate arm no action?
A | Reason | Solution |
1 | Barrier arm at 45° position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 | Tension of balancing spring not suitable | Adjust spring exactly |
3 | Low working voltage | Check the voltage and power |
4) Q: When opening/closing,boom barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?
A. | Reason | Solution |
1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90° vertical and 180° horizontal position |