3 Phase Rating Perkins Engine Generator , 1500 RPM , 4016TWG2

Brand Name:GSKA
Model Number:P1700 / P1875E
Minimum Order Quantity:20-30 pieces
Delivery Time:3-5 days on receipt of official sales contract
Payment Terms:L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

1, Engine Make & Model: Perkins 4016TWG2

2,Generating Set Model: P1875E

3,Alternator Model: LL9124H

4, Circuit Breaker Type: 3 Pole ACB

5, Frequency: 50 Hz / 60 Hz

6,Cycle: 4 Stroke

7, Engine Speed: 1500rpm

8, Cooling Method: Turbo, Water/Air cooling

9, Governing Type: Electronic

10, Output Type: AC Three Phase

10, No.of Cylinders/Alignment: 16 / Vee

11,Base Frame Type:Heavy Duty FabriCAT-parts-partsed Steel


3 Phase Rating Perkins Engine Generator , 50 Hz , 1500 RPM

Output Ratings

Generating Set Model


* P1875E Prime* Standby*


380-415V, 50 Hz


1700.0 kVA 1875.0 kVA

1360.0 kW 1500.0 kW


220/127V, 60 Hz


- -

- -

  • Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.

Technical Data


Engine Make & Model:


Perkins 4016TWG2


Alternator Model:


LL9124H


Base Frame Type:


Heavy Duty FabriCAT-parts-partsed Steel


Circuit Breaker Type:


3 Pole ACB


Frequency:


50 Hz 60 Hz


Engine Speed: RPM


1500 -


Fuel Tank Capacity: litres (US gal)


-


Fuel Consumption: P1700 l/hr (US gal/hr)


354.0 (93.5) -


Fuel Consumption: P1875E l/hr (US gal/hr)


391.9 (103.5) -

P1700 / P1875E

Engine Technical Data

Physical Data Air System 50 Hz 60 Hz


Manufacturer: Perkins

Model: 4016TWG2

No. of Cylinders/Alignment: 16 / Vee

Cycle: 4 Stroke

Induction: Turbocharged

Cooling Method: Water Governing Type: Electronic Governing

Class: ISO 8528 G2

Compression Ratio: 13.6:1

Displacement: l (cu.in) 61.1 (3730.0) Bore/Stroke: mm (in) 160.0 (6.3)/190.0 (7.5) Moment of Inertia: kg m² (lb. in²) 20.72 (70803)

Engine Electrical System:

-Voltage/Ground: 24/Negative

-Battery Charger Amps: 40

Weight: kg (lb) - Dry: 5940 (13095)

- Wet: 6217 (13706)


Air Filter Type: Replaceable Element Combustion

Air Flow:

m³/min (cfm) -Standby: 126.0 (4450) -

-Prime: 114.0 (4026)

- Max. Combustion Air Intake

Restriction: kPa (in H2O) 3.7 (14.9) - Radiator Cooling Air Flow:

m³/min (cfm) 2094.0 (73949) - External Restriction to

Cooling Air Flow: Pa (in H2O) 250 (1.0) -

Cooling System 50 Hz 60 Hz

Cooling System Capacity:


l (US gal) 275.0 (72.6) - Water Pump Type: Centrifugal Heat Rejected to Water &

Lube Oil: kW (Btu/min)

-Standby: 675.0 (38387) -

-Prime: 582.0 (33098) -

Heat Radiation to Room:

kW (Btu/min) -Standby: 213.0 (12113) -

-Prime: 190.0 (10805)

- Radiator Fan Load: kW (hp) 32.0 (42.9) -

Cooling system designed to operate in ambient conditions up to 50°C (122°F).


Performance 50 Hz 60 Hz


Engine Speed: RPM 1500 - Gross Engine Power: kW (hp)

-Standby: 1598.0 (2143.0) -

-Prime: 1450.0 (1944.0)

- BMEP: kPa (psi)

-Standby: 2092.0 (303.4) -

-Prime: 1898.0 (275.3)

- Regenerative Power: kW 160.0 -

LubriCAT-parts-partsion System


Oil Filter Type: Spin-On, Full Flow Total

Oil Capacity l (US gal): 238.0 (62.9)

Oil Pan l (US gal): 214.0 (56.5) Oil Type: API CG4 15W-40

Cooling Method: Water

Fuel System


Fuel Filter Type: Replaceable Element Recommended

Fuel: Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)


110% 100% 75% 50% Load Load Load Load

P1700


50 Hz 391.9 (103.5) 354.0 (93.5) 265.5 (70.1) 181.5 (47.9)

60 Hz - - - -


P1875E


50 Hz 391.9 (103.5) 292.5 (77.3) 198.5 (52.4)

60 Hz - - -


(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Exhaust System 50 Hz 60 Hz


Silencer Type: Level 1

Silencer Model & Qty: SD350 (1) Pressure Drop Across

Silencer System: kPa (in Hg) 0.40 (0.118)

- Silencer Noise Reduction

Level: dB 17 - Max. Allowable Back

Pressure: kPa (in. Hg) 6.4 (1.9) - Exhaust Gas Flow:

m³/min (cfm) -Standby: 340.0 (12007) -

-Prime: 340.0 (12007)

- Exhaust Gas Temperature: °C (°F)

m³/min (cfm) -Standby: 495 (923) -

-Prime: 495 (923) -

P1700 / P1875E


Alternator Performance Data


Data Item

50 Hz 60 Hz

415/240V

400/230V

380/220V


Motor Starting Capability* kVA


6986


6509


5897


Short Circuit Capacity** %


300


300


300


Reactances: Per Unit

Xd X'd X''d


2.740


0.210


0.107


2.950


0.220


0.116


3.270


0.250


0.128

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.


Alternator Technical Data

Physical Data Operating Data


Manufacturer: FG WILSON


Overspeed: RPM 2250


Model: LL9124H


Voltage Regulation (steady state) (%): + /- 0.5


No. of Bearings: 1


Wave Form NEMA = TIF: 50


Insulation Class: H


Wave Form IEC = THF: 2.0%


Winding Pitch Code: 2/3 - 6S


Total Harmonic Content LL/LN: 2.5%


Wires: 6

Supression is in line with European Standard

Radio Interference: EN61000-6


Ingress Protection Rating: IP23


Radiant Heat: kW (Btu/min)


-50 Hz: 64.1 (3645)


-60 Hz: -


Excitation System: AREP


AVR Model: R449

P1700 / P1875E


Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz,- RPM



Voltage Prime Model Standby Model Voltage Prime Model Standby Model

P1700 P1875E - -


kVA kW

kVA kW


kVA kW

kVA kW

415/240V

1700.0 1360.0

1875.0 1500.0




400/230V

1700.0 1360.0

1875.0 1500.0




380/220V

1700.0 1360.0

1875.0 1500.0




Definitions


Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.



Weights and Dimensions

General Data


Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


Warranty

All equipment carries full manufacturer's warranty.


China 3 Phase Rating Perkins Engine Generator , 1500 RPM , 4016TWG2 supplier

3 Phase Rating Perkins Engine Generator , 1500 RPM , 4016TWG2

Inquiry Cart 0