Inverter with Charger

Brand Name:First
Certification:CE,ISO9001
Model Number:1KW
Minimum Order Quantity:1PCS
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Zhongshan Guangdong
Business type: Manufacturer, Exporter, Seller
Address: Building B, No.8, Shentang First Road, No.3 Industrial Zone, Tanzhou Town, Zhongshan City
Supplier`s last login times: within 15 hours
Product Details Company Profile
Product Details
Model12VDC Series
Power1.0KW

Line Mode Specifications:

Input Voltage Waveform

Sinusoidal (utility or generator)

Nominal Input Voltage

110-120Vac

Low Line Disconnect

80Vac±4% / 90Vac±4%

Low Line Re-connect

90Vac±4% / 100Vac±4%

High Line Disconnect

140Vac±4%

High Line Re-connect

135Vac±4%

Max AC Input Voltage

0~150Vrms

Nominal Input Frequency

50Hz / 60Hz (Auto detection)

Low Line Frequency Re-connect

58±0.3Hz for 60Hz;

48±0.3Hz for 50Hz;

Low Line Frequency Disconnect

57±0.3Hz for 60Hz;

47±0.3Hz for 50Hz;

High Line Frequency Re-connect

64±0.3Hz for 60Hz;

54±0.3Hz for 50Hz;

High Line Frequency Disconnect

65±0.3Hz for 60Hz;

55±0.3Hz for 50Hz;

Output Voltage WaveformAs same as Input Waveform

Over-Load Protection (SMPS load)

Circuit breaker

Output Short Circuit Protection

Circuit breaker

Efficiency (Line Mode)

>95%

Transfer Switch Rating

30Amp for UL & TUV

40Amp for UL

Transfer Time (Ac to Dc)

10ms Max

Transfer Time (Dc to Ac)

10ms Max

Pass through without Battery

YES

Max Bypass Overload Current

40A

Invert Mode Specifications:
MODEL POWER TYPEAny Power Combi Series
APC 1012 ~ 6048
Output Voltage WaveformPure Sine Wave
Rated Output Power (VA/W)1KW
Power Factor0~1.0
Nominal Output Voltage (V)110-120Vac
Nominal Output Frequency (Hz) (Default)60Hz
Auto Tracking Main Frequency (First Connection)
Output Voltage Regulation±10% RMS
Nominal Efficiency>88%
Over-Load Protection
(SMPS Load)
(110%(125%( Load>150%) ±10%: Fault (shutdown output) after 20s;
Surge Rating3.0
Capable of Starting Electric Motor1HP
Output Short Circuit ProtectionCurrent Limit Function (Fault after 1sec)
Bypass Breaker Size10A
Nominal DC Input Voltage12.0Vdc
Min DC Start Voltage10.0
Low Battery Alarm10.5
Low DC Input Shut-Down10.0
Low DC Input Auto-Restart13.0Vdc
High DC Input Alarm & Fault16.0Vdc
High DC Input Recovery15.5Vdc
Power Saver Function
Remark:
Detail P/S setting refers Appendix 1.
Load ≦25W
(Enabled On “P/S AUTO” Setting of Remote Control)

China Inverter with Charger supplier

Inverter with Charger

Inquiry Cart 0