Add to Cart
Model | 12VDC Series |
Power | 1.0KW |
Line Mode Specifications: | |
Input Voltage Waveform | Sinusoidal (utility or generator) |
Nominal Input Voltage | 110-120Vac |
Low Line Disconnect | 80Vac±4% / 90Vac±4% |
Low Line Re-connect | 90Vac±4% / 100Vac±4% |
High Line Disconnect | 140Vac±4% |
High Line Re-connect | 135Vac±4% |
Max AC Input Voltage | 0~150Vrms |
Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
Low Line Frequency Re-connect | 58±0.3Hz for 60Hz; 48±0.3Hz for 50Hz; |
Low Line Frequency Disconnect | 57±0.3Hz for 60Hz; 47±0.3Hz for 50Hz; |
High Line Frequency Re-connect | 64±0.3Hz for 60Hz; 54±0.3Hz for 50Hz; |
High Line Frequency Disconnect | 65±0.3Hz for 60Hz; 55±0.3Hz for 50Hz; |
Output Voltage Waveform | As same as Input Waveform |
Over-Load Protection (SMPS load) | Circuit breaker |
Output Short Circuit Protection | Circuit breaker |
Efficiency (Line Mode) | >95% |
Transfer Switch Rating | 30Amp for UL & TUV 40Amp for UL |
Transfer Time (Ac to Dc) | 10ms Max |
Transfer Time (Dc to Ac) | 10ms Max |
Pass through without Battery | YES |
Max Bypass Overload Current | 40A |
Invert Mode Specifications: | |
MODEL POWER TYPE | Any Power Combi Series |
APC 1012 ~ 6048 | |
Output Voltage Waveform | Pure Sine Wave |
Rated Output Power (VA/W) | 1KW |
Power Factor | 0~1.0 |
Nominal Output Voltage (V) | 110-120Vac |
Nominal Output Frequency (Hz) (Default) | 60Hz |
Auto Tracking Main Frequency (First Connection) | |
Output Voltage Regulation | ±10% RMS |
Nominal Efficiency | >88% |
Over-Load Protection (SMPS Load) | (110%(125%( Load>150%) ±10%: Fault (shutdown output) after 20s; |
Surge Rating | 3.0 |
Capable of Starting Electric Motor | 1HP |
Output Short Circuit Protection | Current Limit Function (Fault after 1sec) |
Bypass Breaker Size | 10A |
Nominal DC Input Voltage | 12.0Vdc |
Min DC Start Voltage | 10.0 |
Low Battery Alarm | 10.5 |
Low DC Input Shut-Down | 10.0 |
Low DC Input Auto-Restart | 13.0Vdc |
High DC Input Alarm & Fault | 16.0Vdc |
High DC Input Recovery | 15.5Vdc |
Power Saver Function Remark: Detail P/S setting refers Appendix 1. | Load ≦25W (Enabled On “P/S AUTO” Setting of Remote Control) |