PLC Control Package Carton CompressionTest/ Testing Machine

Brand Name:HAIDA
Certification:ISO 9001:2000; ISO 9001:2008; QS-9000; ISO 14001:2004; CE, , SMC, CMC, CPA, CE,CMA,IMC
Model Number:HD-A534
Minimum Order Quantity:1 Set
Delivery Time:20 days after order confirmed
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash, escrow
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

PLC Control Package Carton CompressionTest/ Testing Machine


Clamp Compression Testing Method of Large Products:

1. Before placing the packaged product between platens, verify that the clamp force using the clamp indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.

2. Each time the product is clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.

3. Apply the clamp force on the sample with the platens resting on the floor and the front edge of the platens flush with the front of the package (see flush platen photo 4). If the package is too large for the clamps to be flush to front edge (i.e., large refrigerator, tractor etc.), clamp as close to the edge as possible.

4. Clamp the product a total of 10 times in the flush orientation.

5. Apply the clamp force on the packaged product with the platens in a 6×6 inch(15.2x15.2cm) offset position(see fig 5 ). Both the horizontal and vertical offset dimensions are measured at the front bottom corner of the platen. If the package is too large for the clamp to be positioned 6-inches from the front edge (i.e., large refrigerator, tractor etc.), clamp as close to this position as possible.

1) Exception number 1: for large products with an obvious, visible external skid(see fig 6), offset clamp testing is not conducted if the product does not extend beyond any part of the skid and there is some form of handling graphic or note that indicates to clamp only from the skid. If there is no graphic or not indicating this or there is some overhang beyond the skid, then the entire clamp test protocol is conducted.

2) Exception number 2: If the product height, when placed in its normal shipping orientation, is ≤ 12 inches, the 6 x6 inch offset testing is not conducted.

6. Clamp the product a total of 10 times with the clamp in the 6 x6 inch offset position.

7. Repeat step 5.2.5 except with a 2 x6 inch offset clamp position. The 2 x6 inch offset is similar to the 6 x6 inch offset except the platens are oriented such that they are 2-inches from the floor and 6-inches back from the package’s front edge. If the package is too large for the clamps to be positioned 2-inches from the front edge (i.e., large refrigerator, tractor etc.), clamp as close to this position as possible.

8. Repeat flush and offset clamping on all other sides of the product that are indicated in the handling graphics as acceptable for clamp handling.

According to verdict standards, if there is one item failed the test, then put forward the “Test Failure Handling Sheet

Safety protection:

Overload protection, overvoltage protection & limited position protection device

ModelHD-A534
Design standardASTM D642, ASTM D6055, American SEARS enterprise standard
Sample shapeparallelepiped transport package
Maximum test weight500KG
Clamping pressure400-3000Lb (adjustable) pressure can be applied on the corresponding surface according to the transportation diagram on the test sample
Plywood sizeH48in * D48in
Clamping plate height adjustment0-1000mm
Lifting speed50-300mm / min, set fixed speed
Spreading plate width200-2000mm
Dimensions2000 * 2800 * 2350mm
Sensor accuracy1/100000
Measurement accuracy1%
Clamping displacement accuracy± 0.5MM
Power controllerTouch screen Chinese display maximum power value burst
Splint requirementsTwo gripping plates are 2000lb parallel and flat without deformation under working conditions, the vertical state between the splint and the floor, the thickness of the splint is ≥15mm, the splint can realize the action and cycle of clamping, opening, rising, and lowering cycle
Automatic stop modeset the upper and lower limits to stop
Transmission modeservo motor controls clamping force, and AC motor controls rise and fall
Protection deviceleakage protection, travel limit device
Working voltageAC 220V / 50HZ

Specifications:

Package clamp testing machine
1. Up to ASTM D6055
2. PLC control

China PLC Control Package Carton CompressionTest/ Testing Machine supplier

PLC Control Package Carton CompressionTest/ Testing Machine

Inquiry Cart 0