Class I+II / Type 1+2 Surge Protection For Power transfer
equipment
*DC surge protector is an electrical component used to limit
transient over-voltage phenomenon. Because it needs to operate for
a long time, there will be aging. If the DC surge protector is used
for a long time, the aging caused by it will not be timely. If the
facility is updated, it may cause performance degradation, failure
and other malfunctions. Therefore, the DC surge protector needs to
be inspected regularly. If the inspection result shows aging or the
status indicator is invalid, please replace the DC surge protector
in time.
OBV5-I-25
Class I+II surge arrester, OBV10-I-25 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.
Technical Parameters
Model: OBV10-I-25-Pluggable | |||
Maximum continuous operating voltage | Uc | V | 255/275/320/385 |
SPD to EN 61643-11 | Type 1+2 | ||
SPD to IEC 61643-1 | class I+2 | ||
LPZ | 0→2 | ||
Lightning impulse current (10/350μs) | Iimp | kA | 25 |
Lightning impulse current (10/350μs) [total] | kA | 100 | |
Nominal discharge surge current (8/20μs) | In | kA | 25 |
Arrester surge current (8/20μs) [total] | kA | 100 | |
Voltage protection level | Up | kV | 2,0 |
Response time | tA | ns | <100 |
Follow current quenching capacity Ipeak | Ifi peak | kA | 25 |
Maximum back-up fuse | A | 315 | |
Temperature range | ϑ | °C | -40℃~+85℃ |
Protection rating | IP 20 | ||
Connection cross-section, rigid | mm² | 10-50 | |
Connection cross-section, multi-wire | mm² | 10-35 | |
Connection cross-section, flexible | mm² | 10-25 |
Feature&Benefits
1,Protect electric system and on-loading electrical apparatus from
thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC
power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with
3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be
customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) | Max Discharge Current | Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 | 275/320 | 5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are
available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.