Pentair 42002-0024S Stack Flue Sensor Replacement For Pool And Spa Heater Electrical Systems

Brand Name:UCHI
Certification:ROHS
Model Number:NSAB1802JD8-650T2I
Minimum Order Quantity:500PCS
Delivery Time:7-10 Days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 810, Unit 2, Building 5, Huixing Commercial Center, Dongsheng Road No.1, Zhongshan Dong, Shilong Town Dongguan, GUANGDONG, 523326 CN
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details


Pentair 42002-0024S Stack Flue Sensor Replacement NTC Temperature Sensor For Pool and Spa Heater Electrical Systems


Specification download link : NSAB1802JD8-650T2I SPEC.pdf
Installation method download link : Stack Flue Sensor Insulation.pdf


Description


A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F. When this fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced.

This replacement stack flue sensor from Optimum Pool Technologies is compatible with Pentair’s MasterTemp, Max-E-Therm, and other Pentair Sta-Rite heaters. It is designed specifically to replace the Sta-Rite heater stack flue sensor.

Location:The Indoor Stack Flue Switch (ES2)/Stack Flue Sensor (SFS) Is Located on the Exhaust Elbow.



Dimension (mm)

NOCOMPONENTMATERIAL AND SPECIFICATIONSQ'TYREMARK
2-1ELEMENTR200:8KΩ ±5% R150/250:5300K ±3% DDR1 PCS 
2-2LEAD WIRETPEF AWG22*1C 320℃65mm(White )
2-3COATINGEpoxy resin(Black)
2-4HOUSINGJM19105 Φ6.35*54.6+S13+24UNF SUS3041 PCS
2-5TERMINOLAMP 250 #22-#182 PCS(Red)
Performance
NOItemSignTest ConditionsMin.Normal valueMax.Unit
4-1.Resistance at 200℃R200

Ta=200±0.05℃

PT≦0.1mw

7.688.4
Resistance at 150℃R150

Ta=150±0.05℃

PT≦0.1mw

/29.65/
Resistance at 250℃R250

Ta=250±0.05℃

PT≦0.1mw

/2.705/
4-2.B ValueB150/250514153005459k
4-3.

Dissipation

Coefficient

σIn the air3/mw/℃
4-4.Time constantτIn the air//15sec
4-5.Insulation resistance/500VDC100//
4-6.Withstand voltage/1500V AC5//Sec
4-7.Operating temp.range//-30/+300


Reliability Test

NOItemTechnical requirementsTest conditions and method
5-1.High temp. Test

DR/R25£±3%

DB/B£±3%

No change with withstand voltage,
Insalution performance.
Appearance without damage.

105±5℃,1000±24 hrs
5-2.Low temp. tes-30±5℃,1000±24 hrs
5-3.Endure moisture testStore in environment 65±2℃,90%-95%RH for 1000±24 hrs
5-4.Temp. cycle testPlace the sample in -30℃ for 10 min, in 25℃ for 10 min and in 100 ℃ for 10 min. and repeat for 5 times.
5-5Tensile tests

After tensile test, the sensor should be
no damage and no falling.zero power
resistance change rate should be less
than ±1% in 25℃

Clamp wire at 50mm away from the inner edge of the connector terminal, then put 10N static tension between terminal and wire for 1min, along axial direction.after the test, check if there is any borken wire, falling off or damage and measure zero-power re.
5-6Drop test

No technical damage. zero power
resistance change rate should be less than ±1% in 25℃

Drop the sensor from a meter high through axial and lateral direction to cement floor, each direction for 5 times.then check the appearance and measure zero-power resistance in 25℃
5-7Vibration testFrequency range:10-500HZ,accelerated speed:10g,frequency sweep time: both X and Y for 30 min.recover for 4 hours after test, visual inspect the appearance of the sensor and measure zero- power resistance in 25℃



6.1 In the process of storage and transportation, per stack height is not more than 4 CTN products.
6.2 Available with all transport method, but avoid the rain, snow of direct or indirect leaching and mechanical damage.

6.3 Products should be stored in the temperature of environment - 10 ℃ / + 40 ℃, relative humidity is not more than 80%, environment should not have acid, alkali and corrosion gas or radioactive source.


Attention on operation

7.1 It will bring extra heat and affect testing precision when the current pass through the sensor, With a view to it before selecting sensor.
7.2 When the product moves, the installation must be handled gently to avoid damage caused by pulling the product.
7.3 Product deformation, oxidation and other phenomena, can not be used, so as not to affect the temperature accuracy.
7.4 Excessive temperature variations should be avoided within the operating temperature range.
7.5 Do not use in corrosive gases (such as CO2,NH3,SOX,NOX, etc.) beyond specified conditions.
7.6 Do not use in electrolysis, salt, acid, alkaline and organic solvents beyond specified conditions.
7.7 In the limit temperature, the product can withstand too high or too low temperature shock in the short term, but can not put the product in the limit temperature for a long time, in order to avoid shortening the service life of the product.

If you need any help, please consult our sales staff or engineers, thank you !