Product Details

High power density DC module

EV4850M2 rectifier Module

Input: 90-290Vac; output : 43-58VdcCapacity:2900W


Perfect Application

48Vdc distributed system

Ethernet

Inter-changer

LAN(local area network)

Server

Indoor wireless network

Telecommunications equipment

Features:

u Compact structure, power density up to 23.5W/in3

u Output voltage adjustable 43-58Vdc, default 53.5V

u Wide working temperature range: -40~+45°C, (extended optional: +45~+65°C)

u Power factor correction ≥0.98

u RS485 communication interface

u Input over-voltage protection

u Output over-voltage protection

u Output over-current protection

u Over temperature alarm and protection

u Parallel via bus current equalizing

u Remote control On/Off

u Hot swap

u Comply to UL1 60950, CSA2C22.2 60950-00, VDE30805 IEC60950 requirements

u CE4 marking complies with 73/23/EEC and 93/68/EEC directives

u High efficiency, >95%


1.Specification:


Input
ParameterMIN.ClassicMAX.UNITRemark
Input voltage90110/220290VacLong rime bearing with 320VAC, no damage
Input frequency4550/6065HzRated load
Input current18.5A176VAC full load
PF0.98Rated input /rated load
Power conversion151155159VacCapacity decrease from 2900W to 1200W
146150154Vac

Output
ParameterMIN.ClassicMAX.UNITRemark
Output voltage4353.558VdcSettable by monitor(condition :without load)
Output current05053A
accuracy±0.6%
Ripple Value(Max)200mVIn the rated input/output, plus one 0.1uF ceramic capacitor and one 10uF high frequency electrolytic capacitor each, the bandwidth is 20MHz.
Output capacity29002950WInput range within 154-290V
1200WInput range within 90-154V
Output efficiency9595.6%220V AC input ,25%-75%load
86%110V AC input range
Dynamic response overshoot±5%
Dynamic response time200us25%-50%-25% or 50%-75%-50% load change, jump rate 0.1A/us, transition period 4ms, equal upper and lower half cycles.
Start up time310SThe rated input voltage is switched on until the output voltage reaches 42VDC; To start output, it requires to use the pre-limit current function.
ON/OFF overshoot±5%
Unbalance level±5176-290Vac,50%-100% load
Telephone weight noise2mV
Broadband noise voltage

100

30

mV

(3.4KHz~150KHz)

(150KHz~30MHz)

Discrete noise

5

3

2

1

mV

3.4-150KHz

150-200KHz

200-500KHz

500-30000KHz


Protection
ParameterMIN.ClassicMAX.UNITRemark
Input overvoltage protection300310320VdcSelf-recovery, restore voltage 10V
Input overvoltage protection recovery point290Vdc
Input undervoltage protection758085VdcSelf-recoverable
Input undervoltage protection recovery point90Vdc
Output overvoltage protection point596061VLocked up
Output current limit protection54ASelf recovery
Short circuit protectionLong-term short circuit; self-healingASelf recovery
Power over temperature protectionAutomatic recovery at ambient temperature 60°CC

Environment
ParameterMIN.ClassicMAX.UNITRemark
Operating temperature-4065°C
Transportation environment temperature-4070°C
Storage temperature-4070°C
Humidity595%Non-condensation
Altitude04000m3000-4000m, use high temperature derating under ambient conditions, drop 1°C for every 200m increase
Seismic level4Zone
Atmospheric pressure70106KPa
Noise4555dBNoise is proportional to fan speed, load size, and ambient temperature
Sleep power consumption4W
Remark: At 45°C, the module can output the maximum output power without over-temperature protection; when it is higher than 45°C, the module power is automatically derated. When it rises to 65°C, the module is over-temperature protected.

EMC and others
ParameterStandard
Radiated Emission (CE)EN55022 - Class A
Conducted Emission (RE)Input :EN55022 - Class A output :Class A
Electrostatic discharge

EN/IEC 61000-4-2

Contact discharge ± 6KV, Air discharge ± 8KV, Criterion B; Contact discharge ± 8KV, Air discharge ± 10KV, Criterion R

Contact discharge ±2KV, criterion R

Harmonic emissionEN/IEC61000-3-2 CLASS A
Radiated immunityEN/IEC 61000-4-3 Level 3 (10 V/m).
Conducted immunityEN/IEC 61000-4-6 Level 3 (10 V/m).
Fast transient burstEN/IEC 61000-4-4 Level 3 (2 kV, 5 kHz repeating)
SurgeEN/IEC 61000-4-5 Level 3 Criterion: B,L-L :±2KV,L-G:±4KV

Lightning impact

No failure

No damage

EN/IEC61000-4-5 Level 4 (common mode 4kV, differential mode 2kV)

ANSI C62.41 Level A3 (Common Mode and Differential Mode 6kV)

Voltage Dips and Short-Time Interrupt Immunity (DIP)EN/IEC61000-4-11 drops to 70%, 40%, 0% Ut for durations of 100ms, 20ms, 10ms at 0°, 45°, 90°, 135°, 180°, 225°, 270°, 315 ° Each phase falls and meets criterion B
Voltage fluctuations and flickerEN/IEC61000-3-3 Pst ≤ 1.0; P1t ≤ 0.65; dc ≤ 3%; dmax ≤ 4%; d(t) value exceeds 3% of the time ≤ 200ms
Reliability (Calculation)≤250,000 Hours
Parallel functionN+1,unblance within ±5%;
Voltage Dips and Short-Time Interrupt Immunity (DIP)Sinusoidal vibration: 5 - 9Hz; Amplitude 3.5mm; 9-200Hz; Acceleration spectral density: 10m2/s3; 3 axial, sweep frequency vibration 5 times in each direction, 1OCT/MIN (1 octave/min)
Voltage fluctuations and flickerRandom vibration: 2-10 Hz, 10 m2/s3; 10-200 Hz: 3 m2/s3; 200-500 Hz: 1 m2/s3; 3 axial directions, each 30 min.

Insulation class
ParameterStandardRemark
input Output3000Vac/10mA//1minNo arcing, no breakdown, with discharge tube removed during test
Input - Earth1500Vac/10mA//1min
Output - Earth1500Vac/10mA//1min
Contact current (input to ground)≤3.5 mAInput 264Vac /50HZ
Insulation resistance≥10MΩUnder normal atmospheric pressure, when the relative humidity is 90% and the test voltage is 500V DC, the insulation resistance of the power input to the output, the input to the ground, and the output to the ground shall not be lower than 10MΩ.

Mechanical properties
D*W*H242.1*102.7*83.8mm
Weight (kg)≤3.8Kg


2.Function


Output over-voltage shutdown


If the output voltage exceeds the preset value, the rectifier will automatically shut down. Reduce the overvoltage shutoff point by approximately 1V at full load to ensure that the rectifier shuts off smoothly during overvoltage. Overvoltage shutdown voltage can be adjusted and set at the factory.

Hot-swap


When quick plugging and unplugging of the module is performed, the inside of the module should be fully discharged to ensure that the automatic restart of the module can be completed smoothly. To ensure sufficient internal discharge of the power supply, observe the rotation of the fan after the module is removed. Do not insert the module until the fan stops rotating.


Input inrush current

When the rectifier is started, the input impulse current peak value is not more than 2 times the maximum input current. At startup, the output voltage and current will rise slowly from zero, providing a soft load characteristic for the device.


Over temperature protection

When the rectifier reaches its maximum operating temperature, the rectifier gradually reduces the output current to lower its internal temperature. In extreme environments, the internal temperature of the rectifier may continue to rise even if the output current is reduced. In this case, the rectifier will be completely shut down and restart automatically after the internal temperature returns to normal.

When fully loaded, the rectifier operating temperature: -40 ~ +45 °C, the maximum operating temperature is +65 °C, in the +45 ~ +65 °C temperature rectifier under load, in order to maintain its internal temperature within the normal range.


Current equalizing


Current sharing characteristics


When sharing several rectifiers in the system, the rectifier will effectively share current. Each rectifier's hardware monitors the bus voltage and adjusts its own output current to match other rectifiers.

Forced air cooling

The rectifier constantly monitors its internal temperature, ambient temperature, and output current to adjust fan speed. This type of fan speed control reduces noise and dust build-up. If a fan stops working and cannot be restarted by the microcomputer, a fan failure alarm signal will be issued and the rectifier output current will be reduced.

3.Signal


Socket typePinSignal meaningLabelingContact sequence

AC input (J1)

FCI 51939-021

1Module AC inputL2
2Module protectionPE1
3Module AC inputN2

DC output and signal (J2)

FCI 51939-022

1Module address lineADDRESS03
2Module address lineADDRESS13
3Modules are streamlinedLOADSHARE+3
4NCNC3(kept)
5NCNC3(kept)
6NCNC3(kept)
7Module address lineADDRESS23
8Module address lineADDRESS33
9Modules equalizing lineLOADSHARE-3(kept)
10RS485 ++5V3
11RS485 -+5VGND3
12Module communication lineRS485-3
13Module address lineADDRESS43
14NCNC3(kept)
15Module communication lineRS485+3
16Address line GNDADDR_GND3
PrechargePre-Charge1
Module output 48V+DC+2
Module output 48V+DC+2
Module output 48V-DC-1
Module output 48V-DC-1

LED Indicator
Indication markIndicator colorStatusInstruction Meaning
Normal

green


ONMains input is normal and module is working normally
OFFMains failure (no AC input, AC input overvoltage, no output from the module)

Protection indicator


yellow


OFFNo module failure
ONThe power module is abnormally temperature-pre-alarmed; it sleeps and shuts down (only the protection indicator is on when the device is powered off, and the module does not report alarms).
Fault indicatorredOFFNo module failure
ONThe red light is on when the output is over voltage shutdown, fan failure, over temperature shutdown, or no output due to the internal cause of the module.