3RW4027-1TB04 Siemens Sirius Soft Starter Screw Terminals Thermistor Motor Protection

Brand Name:SIEMENS
Model Number:3RW4027-1TB04
Minimum Order Quantity:1PC
Delivery Time:60-80 work days
Payment Terms:T/T, Western Union,Paypal
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China
Supplier`s last login times: within 23 hours
Product Details Company Profile
Product Details

SIEMENS SIRIUS Soft Starter 3RW4027-1TB04 Screw Terminals Thermistor Motor Protection

Product Description:

SIRIUS soft starter S0 32 A, 15 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Screw terminals Thermistor motor protection.


General technical data 
product brand nameSIRIUS
product feature 
● integrated bypass contact systemYes
● thyristorsYes
product function 
● intrinsic device protectionYes
● motor overload protectionYes
● evaluation of thermistor motor protectionYes
● external resetYes
● adjustable current limitationYes
● inside-delta circuitNo
product component motor brake outputNo
insulation voltage rated valueV 600
degree of pollution3, acc. to IEC 60947-4-2
reference code according to EN 61346-2Q
reference code according to DIN 40719 extended
according to IEC 204-2 according to IEC 750
G
  
Power Electronics 
product designationSoft starter
operational current 
● at 40 °C rated valueA 32
● at 50 °C rated valueA 29
● at 60 °C rated valueA 26
yielded mechanical performance for 3-phase motors 
● at 230 V 
— at standard circuit at 40 °C rated valuekW 7.5
● at 400 V 
— at standard circuit at 40 °C rated valuekW 15
yielded mechanical performance [hp] for 3-phase AChp 7.5
motor at 200/208 V at standard circuit at 50 °C rated 
value 
  
operating frequency rated valueHz 50 ... 60
relative negative tolerance of the operating frequency-10%
relative positive tolerance of the operating frequency10%
operating voltage at standard circuit rated valueV 200 ... 480
relative negative tolerance of the operating voltage at-15%
standard circuit 
  
relative positive tolerance of the operating voltage at10%
standard circuit 
10% 
minimum load [%] % 2020%
adjustable motor current for motor overloadA 17
protection minimum rated value 
continuous operating current [% of Ie] at 40 °C115%
power loss [W] at operational current at 40 °C duringW 13
operation typical 
Control circuit/ Control 
type of voltage of the control supply voltageAC/DC
control supply voltage frequency 1 rated valueHz 50
control supply voltage frequency 2 rated valueHz 60
relative negative tolerance of the control supply-10%
voltage frequency 
  
relative positive tolerance of the control supply10%
voltage frequency 
  
control supply voltage 1 at AC 
● at 50 Hz rated valueV 24
● at 60 Hz rated valueV 24
relative negative tolerance of the control supply-15%
voltage at AC at 50 Hz 
  
relative positive tolerance of the control supply10%
voltage at AC at 50 Hz 
  
relative negative tolerance of the control supply-15%
voltage at AC at 60 Hz 
  
relative positive tolerance of the control supply10%
voltage at AC at 60 Hz 
  
control supply voltage 1 at DC rated value V 24-20%
relative negative tolerance of the control supply 
voltage at DC 
  
relative positive tolerance of the control supply20%
voltage at DC 
  
display version for fault signalred
Mechanical data 
size of engine control deviceS0
widthmm 45
heightmm 125
depthmm 155
fastening methodscrew and snap-on mounting
mounting positionWith additional fan: With vertical mounting surface +/-90°
rotatable, with vertical mounting surface +/- 22.5° tiltable
to the front and back Without additional fan: With vertical
mounting surface +/-10° rotatable, with vertical mounting
surface +/- 10° t
  
  
required spacing with side-by-side mounting 
● upwardsmm 60
● at the sidemm 15
● downwardsmm 40
wire length maximumm 300
number of poles for main current circuit3
Connections/ Terminals 
type of electrical connection 
● for main current circuitscrew-type terminals
● for auxiliary and control circuitscrew-type terminals
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts2
number of CO contacts for auxiliary contacts1
type of connectable conductor cross-sections for 
main contacts for box terminal using the front 
clamping point 
● solid2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm²
● finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
type of connectable conductor cross-sections at AWG 
cables for main contacts for box terminal 
● using the front clamping point1x 8, 2x (16 ... 10)
type of connectable conductor cross-sections for 
auxiliary contacts 
● solid2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections at AWG 
cables 
● for auxiliary contacts2x (20 ... 14)
● for auxiliary contacts finely stranded with core end processing2x (20 ... 16)
  
Ambient conditions 
installation altitude at height above sea levelm 5 000
environmental category 
● during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
● during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist),
1S2 (sand must not get inside the devices), 1M4
● during operation according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt
mist), 3S2 (sand must not get into the devices), 3M6
  
ambient temperature 
● during operation°C -25 ... +60
● during storage°C -40 ... +80
derating temperature°C 40
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
UL/CSA ratings 
yielded mechanical performance [hp] for 3-phase AC motor 
  
● at 220/230 V 
— at standard circuit at 50 °C rated value hp 7.5hp 7.5
● at 460/480 V 
— at standard circuit at 50 °C rated valuehp 20
contact rating of auxiliary contacts according to ULB300 / R300

Dimensional drawings:

China 3RW4027-1TB04 Siemens Sirius Soft Starter Screw Terminals Thermistor Motor Protection supplier

3RW4027-1TB04 Siemens Sirius Soft Starter Screw Terminals Thermistor Motor Protection

Inquiry Cart 0