Model Number: DMF-ZM-20
Standard or Nonstandard:Standard
Structure:Diaphragm
Power:Solenoid
Media:Gas
Material:Alloy
Port Size:3 Inch
Pressure:Low Pressure
Temperature of Media:Medium Temperature
Specification
DMF-ZM-20 | |
Center hole distance | Φ80 |
Kv/Cv | 17.55/20.48 |
Blowing area(m²) | 8~10 |
Air inlet/Outlet size | Φ34 Φ34 |
Weight(kg) | 1.3 |
DMF-ZM-40S | |
Center hole distance | Φ112 |
Kv/Cv | 45.82/53.47 |
Blowing area(m²) | 12~16 |
Air inlet/Outlet size | Φ27 Φ27 |
Weight(kg) | 1 |
Drawings
Delivery
1. If the products we have in store, we will send it out ASAP after
payment.
2. If the products which were customized, we will complete the
production within a specified period of time, and send it out the
first time, we can promise it.
3. Also we can send by your delivery acount if you want.
4. We have a variety of ways to send goods, usually DHL, Fedex, TNL
will be normal ways. If you require use of a courier, we can do it.
Competitive Advantage
Our product features | Our Services Guarantee: |
1) Competitive price | 1) Prompt respond (Reply with 24 hours) |
2) Good quality | 2) Free Samples (Customer pay for the delivery cost) |
3) Professional Packaging | 3) Registration support. |
4) Produce according to Customers’ instruction | 4) Photos/videos are available during production. |
5) None delay shipment | 5) Loading inspection, and send loading photos before shipment. |
The installment introduction:
1. First, Confirm the pulse valve in good condition and then
installed
2. Pulse valve will be installed directly the outer wall of flange
of gas manifold. The spray pipe across the gas manifold. According
to the drawing and manual, the pulse valve matching appropriate
spray pipe and installation. To avoid the valve install in the air
manifold bottom. If the pulse valve matched trachea and connector,
the connector will be used for sealing purpose only. It can not as
structural support components. It can not rely on the straight
connector fixed spray torch and package. The spray pipe and air
manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten
the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric
control valve seat. Pay attention to the line adown to prevent rain
waterproof. Or through the joint and nylon pipe, it will connect
the pulse valve and electromagnetic assembly boxes of nylon pipe
connection.
5. To ensure that provide compressed air clean and dry. The air
manifold system provides moderate pressure and check for leaks
installation. ( it can brush on soap and water, check whether the
interface is bubble). Pressure was carried out on the air bag
inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa),
recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve
whether it is normal operation and whether the pulse blowing sound
is clear.
After-sale Service
We can provide a series of after-sale service, such as product
introduction, mounting, debugging, technical support and so on.
The exhaust chamber volume of improved DMF pulse valve is
increased. The permeability magnetic material of pulse valve is
increased, and also, the materials of structure of diaphragm and
pressure spring are improved, so that the exhaust volume of valve
is increased to raise the magnetic strength and sensitivity as well
as the element reliability and operation stability of pulse valve.
Its service life will be greatly prolonged.