Input Specification
Input voltage range (See Note 9) | Universal input | 90-264 Vac 120-370 Vdc |
Input frequency range | 47-440 Hz | |
Input surge current | 120 Vac, cold start 230 Vac, cold start | 15 A max. 30 A max. |
Safety ground leakage current | 120 Vac, 60 Hz 230 Vac, 50 Hz | 0.2 mA 0.4mA |
Input current | 120 Vac 230 Vac | 1.4 A rms 0.7 A rms |
Input fuse | UL/IEC127 | 250 Vac H 3.15 A |
Output Specification
Total regulation (Line and load) | Main output ±2.0% Auxiliary outputs | ±2.0% ±5.0% |
Rise time | At turn-on | 1.0 s, max. |
Transient response | Main output 25% step at 0.1 A/μs | 5.0% max. dev., 1 ms rec. to 1.0% |
Temperature coefficient | ±0.02%/°C | |
Overvoltage protection | Main outputs | 135%, ±15% |
Short circuit protection | Cyclic operation | Continuous |
Minimum output current | Single Multiple | 0 A (See Note 5) |