6 Pulse 12 Pulse Low Frequency 3 - Phase Online UPS with Maintain Bypass Switch

Brand Name:SOROTEC
Certification:CE,ROHS,RSO9000
Model Number:GP9335C 10-800KVA
Minimum Order Quantity:2PCS
Delivery Time:Within 15-30days after receiving your 30% TT deposit
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Active Member
Location: Shenzhen Guangdong
Address: Building B22 , Tantou West Industrial Park , Songgang Town , Bao'an District ,Shenzhen ,518105 P.R.CHINA
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

6 Pulse 12 Pulse Low Frequency 3 - Phase Online UPS with Maintain Bypass Switch


Quick Detailes:

SOROTEC GP9335C Series Low Frequency Online UPS 10-800KVA (3Ph in/3Ph out)

Model: 10-800KVA

Nominal Voltage: 380/400/415VAC

Nominal Frequency:50/60HZ

Output Power Factor: 0.9

Parallel:maximum 6PCS UPS

Indicated Language:12 types(En.Ru.Sp.Fr...)


Key Features:

1. On-Line Dual Conversion, fully isolating the influences of power grid pollution and power failure

from utility power supply and diesel generator to load.


2. Advanced 6th generation DSP and full digital control technologies to realize higher system stability.


3. Extra strong capability to withstand output overload and short circuit, ensuring the system stability

and system safety under extreme conditions.


4. Intelligent battery management maintains battery , automatically to prolong the battery life.


5. Advanced distributed active parallel technology can realize parallel operation of 6 UPS units without

the need of centralized bypass cabinet.


6. Extra widely input voltage and frequency range make it adapt to severe power grid environment.


7. Rated at 0.9 output power factor, more applicable to server computer and network center that use

PFC technology in a large scale, and deliver more Active power than conventional UPS.


8. Standard input/output filter improves the system EMC performance.


9. 6-inch extra large LCD that can display 12 language( Chinese .English.Russian.Spanish.French ..)


10. Layered independently - sealed ventilation channel and redundant fan, circuit boards with protective paints and a

dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severe environment.


11. Multi input harmonic suppressing technology improves the utility rate of electric Power Output isolation

transformer with zero phase shift reduces the influences of Neutral to Ground voltage and load harmonic current to inverter


Technical Specifications:


Model
GP9335C 120-800KVA
Rectifier Type6p12p6p12p6p12p6p12p6p12p
Rated Nominal120KVA/108KW160KVA/144KVA200KVA/180KW300KVA/270KW400KVA/36W
Rated input voltage380/400/415VAC 3-phase 4-wire
Rated frequency50/60HZ
Input parameters
Input voltage range±25%
Input frequency range45Hz~65Hz
Input soft start function0-100% 5-300settable
Input power factor>0.98(If harmonic filter is added)
Input harmonic current (THDi)<4.5%(If harmonic filter is added)
Bypass
Bypass voltage range-20%~+15%
Bypass frequency range50/60HZ±10%
Output parameters
Inverter output voltage380/400/415VAC 3-phase 4-wire
Voltage stability±1%(Steady status), ±3%(Transient status)
Frequency50/60Hz
Mains power synchronization window±5%
Actually measured frequency accuracy (internal clock)50/60Hz±0.01Hz
Output power factor0.9(Output 90kW per 100kVA)
Transient response time<5ms
Inverter overload capabilityAt 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s

Short circuit current from inverter

3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds
Maximum Bypass capability1000% for 100ms

Phase shift
characteristic

With 100% balanced load<1°
With 100% imbalance load<1°

Total harmonic
Distortion(THDv)

100% linear load<1%
100% non-linear load<3%
System efficiency (full load)Up to 94% (inverter efficiency is up to 98%)
Rectifier output parameters
Charger output voltage stability1%
DC ripple voltage≤1%
Operating environment
Operating temperature range0~40℃
Storage temperature-25~70℃(Without battery)
Relative humidity0~95% No condensation
Maximum operating height≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m
Noise (1m)58-68dB
Protection levelIP20
StandardSafety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
Physical parameters
Weight (kg)980142012001750135020001600220021002750
Width(mm)900125012501640125016401640228022802280
Depth (mm)855855855855855855855855855855
Height (mm)1900190019001900190019001900190019001900

Applications:
Mainly used in large IDC rooms, bank/securities settlement center, communication network management center, semiconductor product

lines and large automation production and its control system. According to the special needs of users was improved, and used in large

sports venues, conference room, theater and highway and railway tunnels metal halide lamp lighting system.

China 6 Pulse 12 Pulse Low Frequency 3 - Phase Online UPS with Maintain Bypass Switch supplier

6 Pulse 12 Pulse Low Frequency 3 - Phase Online UPS with Maintain Bypass Switch

Inquiry Cart 0