K68i Universal Secondary Injection Relay Test Set Synchronizer Test

Brand Name:KINGSINE
Certification:ISO9001, CE
Model Number:K68i
Minimum Order Quantity:1 set
Delivery Time:15 working days
Payment Terms:T/T in advance, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong
Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Automation Universal Relay Test Set K68i, Single Phase


Advance software functions (optional for selections)


◆ Differential test


◆ State sequence test


◆ Time characteristic test


◆ Advance distance test


◆ Synchronizer test


◆ Fault recurrence (Fault play back)

Basic functions


◆ DC test


◆ AC test


◆ Distance relay test


◆ Harmonic test


◆ Frequency test


◆ 8 pairs binary inputs


◆ 4 pairs binary outputs

Ordering Ref.


ModelCurrent OutputsVoltage Outputs
K683×35A@450VA max4×130V @ 75VA max
K68i3×35A@450VA max

4×300V @ 120VA max


Features


1. 3×35A & 4×300V independent high buren output channels.


2. Lightweight <23.5kg.


3. Inbuilt 6.4" True color TFT LCD display, keyboard and rotary encoder, fully control without laptop.


4. Advance software testing modules for optional.


5. 3-Years guarantee of free repair and life-long maintenance.


6. Free software upgrade.


Application


Testing ItemsANSI® No.
Distance protection relay21
Synchronising or synchronism-check relays25
Undervoltage relays27
Directional Power relays32
Undercurrent or underpower relays37
Negative sequence overcurrent relays46
Overcurrent/ground fault relays50
Inverse time overcurrent/ground fault relays51
Power factor relays55
Overvoltage relays59
Voltage or current balance relays60
Directional overcurrent relays67
Directional ground fault relays67N
DC overcurrent relays76
Phase-angle measuring or out-of-step protection relays78
Automatic reclosing devices79
Frequency relays81
Motor overload protection relays86
Differential protection relays87
Directional voltage relays91
Voltage and power directional relays92
Tripping relays94
Voltage regulating relays--
Overimpedance relays, Z>--
Underimpedance relays, Z--
Time-delay relays--

Characteristic


1. 7 Channels (4V + 3I) outputs, each output channels are independent and simultaneous control of


magnitude, phase angle and frequency values, able to inject DC, AC sine wave and up to 20 ×


harmonics.


2. Variable battery simulator, DC 0-300V, 120Watts max.


3. Quick relay testing facility in Manual mode.


4. Switch on to fault test(SOTF).


5. GPS sync end-to-end testing.


6. Online Vector display.


7. Automatic test report creation.


8. Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.


Parameter


Voltage Outputs
Output Range & Power2×600V ac (L-L)240VA max each
1×600V dc (L-L)240W max
3×300V dc (L-N)120W max each
Accuracy

±2mV @ 0.2~2V ac


<0.12%Rd + 0.05Rg Guar. @ 2~300Vac


<0.07%Rd + 0.03Rg Typ. @ 2~300Vac

±10mV @ 0.5V ~ 5Vdc


±0.5% @ 5V ~ 300Vdc

Resolution1mV
Distortion<0.1% Guar. / <0.05% Typ.
Current Outputs
Output Range & Power3×35A ac(L-N)450VA max each
1×105A ac(3L-N)1200VA max
3×20A dc(L-N)300W max each
Accuracy

±1mA @ 0.2A~0.5A ac


<0.15%Rd + 0.05Rg Guar. @ 0.5 ~ 35Aac


<0.07%Rd + 0.03Rg Typ. @ 0.5 ~ 35Aac

±5mA @ 0.2A ~ 1Adc


±0.5% @ 1A ~20Adc

Resolution1mA
Distortion<0.1% Guar. / <0.05% Typ.
Frequency Output
Range5 ~ 1000 HZ
Accuracy

<1ppm @ 5~65 Hz


<10ppm @ 65~45 0Hz


<20ppm @ 450~1000 Hz

Resolution0.001Hz
Phase Output
Range-360°~360°
Accuracy<0.05°Typ. / <0.1° Guar.
Resolution0.001°
Aux. DC Voltage Source (Battery simulator)
Range0~300V @ 180W max
Binary Input
Quantity8 pairs
Input Characteristics0 ~ 400Vdc / Potential free
Time resolution<0.1ms
Max. Measuring Time999.999s
Debounce ytime0~25ms
Binary Output
Quantity4pairs
TypePotential free relay contacts,software controlled
Break CapacityVmax: 300Vac Imax: 4A Pmax: 1000VA
Vmax: 300Vdc Imax: 4A Pmax: 300W
Synchronization
Synchronization ModeExternal GPS (Optional)
Harmonic
Superimposed Numbers2 ~ 20times
Power supply & Environment
Nominal Input Voltage110V / 220V /230Vac appointed, ±10%
Nominal Frequency50 / 60Hz
Permissible Frequency45Hz~65Hz
Power Consumption1500 VA max
Connection TypeStandard AC socket 60320
Operating Temperature0℃~55℃
Storage Temperature-20℃~70℃
Humidity<95%RH, non-condensing
Others
PC ConnectionRJ45 Ethernet, 10/100/1000M
Grounding Terminal4mm banana socket
Weight23.5Kg
Dimensions(W×D×H)360×480×140(mm)

China K68i Universal Secondary Injection Relay Test Set Synchronizer Test supplier

K68i Universal Secondary Injection Relay Test Set Synchronizer Test

Inquiry Cart 0