

Add to Cart
DC Switching Power Supply Single Output 50W
Description:
Low cost
Built-in EMI filter
Low output ripple&noise
Approvals: UL,CE
Protections: Over load/Short circuit
2 years warranty
Technical Data
Index Type | S-50-5 | S-50-12 | S-50-15 | S-50-24 |
DC Voltage | 5V | 12V | 15V | 24V |
Voltage Tolerance | ¡À2% | ¡À1% | ¡À1% | ¡À1% |
Rated Current | 10A | 4.2A | 3.4A | 2.1A |
CurrentRange | 10A | 4.2A | 3.4A | 2.1A |
Ripple&Noise(Max.) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Line Regulation | ¡À0.5% | ¡À0.5% | ¡À0.5% | ¡À0.5% |
Load Regulation | ¡À1% | ¡À0.5% | ¡À0.5% | ¡À0.5% |
Rated Power | 50W | 50.42W | 51W | 50.4W |
Efficiency | 71% | 78% | 78% | 82% |
Voltage Adjust Range | +10 -5% | ¡À10% | ¡À10% | ¡À10% |
VoltageRange | 85¡«132VAC/170-264VACauto switch47¡«63Hz;240¡«370VDC | |||
AC Current | 1.3A/115V 0.65A/230V | |||
Inrush Current(Max.) | cold start current¡¡18A/115V 36A/230V | |||
Leakage Current | <0.5mA/240VAC | |||
Overload Protection | 105%¡«150%TYPE£ºCurrent limitation¡¡auto recovery | |||
Over-voltage Protection | ...................... | |||
Over-temperature Protection | ...................... | |||
Temp.Coefficient | ¡À0.03%/¡æ(0¡«50¡æ) | |||
Setup.Rise, Hold Time | 200ms, 100ms, 20ms | |||
Vibration | 10¡«500Hz, 2G 10min, /11cycle, 60min, each axes | |||
Withstand Voltage | I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC | |||
Isolated Resistor | I/P-O/P, I/P-FG, I/P-FG:500VDC/100M¦¸ | |||
Working Temp.Humidity | -10¡æ¡«+60¡æ(REFER TO CHARACTER CURVE), 20%¡«90RH | |||
Storage Temp.Humidity | -20¡æ¡«+85¡æ, 10%¡«95%RH | |||
Dimension | 159¡Á97¡Á38mm | |||
Weight | 0.5Kgs | |||
Safety Standards | UL1012 | |||
EMC standards | FCC PART15J class B |
Note£º
1.All parameters NOT specially mentioned are measured at 230VAC
input , rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load
regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12
twisted pair-wire terminated with a 0.1uf&47uf parallel
capacitor.
4.line regulation:min&max voltage of the rated load.
5.load regulation:load from 0 to 100%.