Efficient galvanized cabinet air cooled heat exchangers for your home
AW12/B-QNNNE, single phase, heating & cooling unit, galvanized
cabinet, R410a air source heat pump.
Air-source heat pumps, often used in moderate climates, use the
difference between outdoor air temperatures and indoor air
temperatures to cool and heat your home, as well as to supply
domestic hot water.
HISEER AW12/B-QNNNE, designed and tested by EN14511, approved by
TUV china branch, adopts the following world famous parts:
* Daikin scroll compressor
* Siemens controller
* SWEP or GEA plate type heat exchanger
* Schneider A/C contactor
* Emersion thermal expansion valve
* Emersion dry filter
*Soft start is standard part
ASHPs supply more energy than they consume. By extracting heat from
the surrounding air, the heat energy released can be up to 4 times
the energy required to power the equipment.
An ASHP system consists of a compressor and a carefully matched
evaporator coil and heat exchanger. A refrigerant liquid which
circulates within the system has a boiling point as low as minus
40˚C and evaporates when absorbing heat from the outside air. It is
possible to extract considerable heat from the air at temperatures
as low as minus 15˚C. The resulting refrigerant gas is then
compressed adding more heat energy and raising its temperature to
around 75˚C. This heat is then passed via the heat exchanger into
water and used to provide space heating through radiators as for
conventional heating systems, or via underfloor heating systems.
AW12/B-QNNNE
AIR TO WATER HEAT PUMP | AW12/B-QNNNE | |
Heat output/Power consumption at 7/35℃ | kW | 13.0/3.6 |
Heat output/Power consumption at 7/45℃ | kW | 12.5/4.2 |
Heat output/Power consumption at 7/55℃ | kW | 12.2/5.3 |
Heat output/Power consumption at 2/35℃ | kW | 11.1/3.5 |
Heat output/Power consumption at 2/45℃ | kW | 10.8/4.2 |
Heat output/Power consumption at -7/35℃ | kW | 8.0/3.5 |
Heat output/Power consumption at -7/45℃ | kW | 7.9/4.2 |
Cool output/Power consumption at 35/7℃ | KW | 11.5/4.3 |
Starting current | A | 36 |
Soft-start relay |
| Included as standard |
Power |
| 220-240V/1PH/50Hz |
Compressor |
| DAIKIN Scroll |
Condenser |
| Brazed plate heat exchanger |
Nominal flow heating medium | l/s | 0.62 |
Internal pressure drop at nominal flow | kPa | 20 |
Air flow | m3/h | 5000 |
Nominal output fan | W | 300 |
Max outgoing heating medium temperature | ℃ | 55℃ |
Dimensions(HxWxD) | mm | 1075x1105x505 |
Pipe connector |
| DN25 |
Weight | kg | 175 |
The above data is tested by EN14511 |