Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 12 2 Lightning Impulse Withstand Voltage (Peak) kV 75 3 Short-time (1min) Power-frequency Withstand Voltage kV 42 4 Rated Frequency Hz 50/60 5 Rated Current A 630 6 Rated Short-time Withstand Current kA 6.3 7 Rated duration of Short-circuit s 4 8 Rated Breaking Current A 9 Limiting Breaking Current kA 10 Rated Making Current kA 6.3 11 Rated Operating Frequency AC-3 Operations/h AC-4 300...
Durable Vacuum Interrupter Bottle 7.2 Kilo Watt 630A Rated Current
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 7.2 2 Lightning Impulse Withstand Voltage (Peak) kV 60 3 Short-time (1min) Power-frequency Withstand Voltage kV 32 4 Rated Frequency Hz 50/60 5 Rated Current A 630 6 Rated Short-time Withstand Current kA 6.3 7 Rated duration of Short-circuit s 4 8 Rated Breaking Current A 5040 9 Limiting Breaking Current kA 6.3 10 Rated Making Current kA 11 Rated Operating Frequency AC-3 Operations/h AC-4...
Power Switch Vacuum Interrupter Bottle , Electrical Vcb Circuit Breaker
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 1.14 2 Lightning Impulse Withstand Voltage (Peak) kV 3 Short-time (1min) Power-frequency Withstand Voltage kV 5 4 Rated Frequency Hz 50/60 5 Rated Current A 250 6 Rated Short-time Withstand Current kA 3.5 7 Rated duration of Short-circuit s 1 8 Rated Breaking Current A 2500 9 Limiting Breaking Current kA 4.5 10 Rated Making Current kA 3 11 Rated Operating Frequency AC-3 Operations/h AC-4...
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 12 2 Lightning Impulse Withstand Voltage (Peak) kV 75 3 Short-time (1min) Power-frequency Withstand Voltage kV 42 4 Rated Frequency Hz 50/60 5 Rated Current A 630 6 Rated Short-time Withstand Current kA 6.3 7 Rated duration of Short-circuit s 4 8 Rated Breaking Current A 9 Limiting Breaking Current kA 10 Rated Making Current kA 6.3 11 Rated Operating Frequency AC-3 Operations/h AC-4 300...
Rotary UV Printer For Conical And Cylinder Shape Bottle Printing With Double Auto Feeding System
In today's competitive market, fast and efficient printing can make all the difference. Our cutting-edge bottle printing technology offers an industrial solution that boasts exceptional speed, flexibility, and quality. Here's why it's a game-changer: Key Features: Lightning-Fast Printing: Our technology delivers blazing printing speeds, taking only 15-30 seconds to print a bottle. This is 6-10 times faster than traditional flatbed printers,...
Guangzhou Forest Science Co., Ltd.
Verified Supplier
16th,Floor,Xiangjiang International Center,#41 Jinlong Road,Nansha Dist.Guangzhou China.
Vacuum Fault Interrupter In Circuit Breaker 5 KV Power Frequency Withstand Voltage
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 1.14 2 Lightning Impulse Withstand Voltage (Peak) kV 3 Short-time (1min) Power-frequency Withstand Voltage kV 5 4 Rated Frequency Hz 50/60 5 Rated Current A 250 6 Rated Short-time Withstand Current kA 3.5 7 Rated duration of Short-circuit s 1 8 Rated Breaking Current A 2500 9 Limiting Breaking Current kA 4.5 10 Rated Making Current kA 3 11 Rated Operating Frequency AC-3 Operations/h AC-4...
German Craft Dc Interrupter For Low Voltage Power Switch Vacuum Contactor
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 1.14 2 Lightning Impulse Withstand Voltage (Peak) kV 3 Short-time (1min) Power-frequency Withstand Voltage kV 5 4 Rated Frequency Hz 50/60 5 Rated Current A 630 6 Rated Short-time Withstand Current kA 8 7 Rated duration of Short-circuit s 1 8 Rated Breaking Current A 6300 9 Limiting Breaking Current kA 6.3 10 Rated Making Current kA 7.56 11 Rated Operating Frequency AC-3 Operations/h AC-4...
Electrical Vacuum Interrupter Integrity Test 20 Years Shelf Life
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 7.2 2 Lightning Impulse Withstand Voltage (Peak) kV 60 3 Short-time (1min) Power-frequency Withstand Voltage kV 32 4 Rated Frequency Hz 50/60 5 Rated Current A 630 6 Rated Short-time Withstand Current kA 6.3 7 Rated duration of Short-circuit s 4 8 Rated Breaking Current A 5040 9 Limiting Breaking Current kA 6.3 10 Rated Making Current kA 11 Rated Operating Frequency AC-3 Operations/h AC-4...
Secondary Sealing Vacuum Interrupter Switch Exhaust For High Voltage Power Switch
Parameter No. MAIN TECHNICAL DATA Unit 1 Rated Voltage kV 12 2 Lightning Impulse Withstand Voltage (Peak) kV 75 3 Short-time (1min) Power-frequency Withstand Voltage kV 42 4 Rated Frequency Hz 50/60 5 Rated Current A 400 6 Rated Short-time Withstand Current kA 4 7 Rated duration of Short-circuit s 4 8 Rated Breaking Current A 9 Limiting Breaking Current kA 4 10 Rated Making Current kA 4 11 Rated Operating Frequency AC-3 Operations/h AC-4 300 12...
Corrosion Resistance Galvanized Power Cable Tray Fittings Cross Arm Support
Cable Tray Galvanized Power Fittings Cross Arm Support Overhead Wire Power Cross Arm Introduction The cross arm is an angle iron fixed horizontally on the top of the pole, with a porcelain bottle on it to support the overhead conductor. The cross arm is an important component of the pole and tower. Its function is to install insulators and accessories supporting conductors and lightning rods, and maintain a certain safety distance according to...
Langfang Zhousheng Metal Products Co., Ltd.
Verified Supplier
North Village South, Xinzhen Town, Wen'an County, Hebei Province, China
Submit “lightning in a bottle” inquiry
This supplier has been verified by Everychina.com. Our verification process includes: 3 on-site visits by Everychina.com's service team!