Product Details
Air Cooled DX Type Air Handling Units
Feature:
Air-cooled direct expansion air handling unit is a professional air conditioning unit launched for special occasions. It has its own cold and heat source and integrates functions such as air handling and automatic control. It has simple system, convenient installation, convenient maintenance, and efficient operation. Features such as low investment.
Technical paramater:
Unit characteristicsModel: SL-ZKW-( ) DX140180240300400500600
Cooling capacity 1*kw68.090.0120.0148.0200.0240.0300.0
Heating capacity 2*kw69.692.1122.8151.5204.8248.0304.0
Air volume 3*m3/h14000180002400030000400005000060000
Static air pressure 3*Pa500600600750750800800
power3N-380V-50Hz
Indoor unitSupply air fan 3*TypeEfficient centrifugal fan
kw7.511.015.018.522.030.037.0
Chilled water coil 4*(option)TypeEfficient copper tube and aluminum fin
Flow m3/h11.715.520.625.434.441.251.6
Section length(mm)300400400400400400400
Heater 5*TypeStainless steel tube electric heating/ steam heating coil/hot water heating coil
kw3648607296120150
Section length(mm)400400400400500500600
Humidifier 5*TypeElectrode type/steam/electrothermic type/wet film
kg/h15152121304560
Section length(mm)400400600600600600600
Filter 6*TypePrimary filter G4(medium effect F8/ Nanocrystalline carbon filter
NoisedB(A)65686872757580
Overall dimension 7*Length(mm)2600280030003000320035003800
Width(mm)1650165019601960227025803270
Height(mm)1420173017302040234026502650
Weightkg88098010801180128014501800
Outdoor unitModel: SL-WL6545*2120150200120*2150*2
Compressor ATypeHermetic scroll type (Fixed frequency system)
Qty22*24464*24*2
Input power Akw22.429.238.243.467.278.097.2
Compressor BTypeHermetic scroll type (Inverter system)
Qty22*24464*24*2
Input power Bkw22.228.236.242.566.076.595.5
Refrigerant 8*TypeR22/R407C/R410A
ModeExternal balance type thermal expansion valve/electronic expansion valve
Noise 9*dB(A)67687072757578
Overall dimensionLength(mm)18801880*22250255038302250*22550*2
Width(mm)98098021002100210021002100
Height(mm)1234108021002100210021002100
Weightkg400320*295012001800950*21200*2
Connection pipe size 10*Liquid pipe(mm)

19.05*2

(15.88*2)

15.88*4

(12.7*4)

15.88*4

(12.7*4)

19.05*4

(15.88*4)

19.05*6

(15.88*6)

15.88*8

(12.7*8)

19.05*8

(15.88*8)

Steam pipe(mm)

34.9*2

(28.6*2)

22.23*4

(19.05*4)

28.6*4

(22.23*4)

34.9*4

(28.6*4)

34.9*6

(28.6*6)

28.6*8

(22.23*8)

34.9*8

(28.6*8)


1. Cooling condition: indoor dry bulb/wet bulb 27/19℃; outdoor dry bulb/wet bulb 35/24℃

2. Heating condition: indoor dry bulb/wet bulb 20/-℃; outdoor dry bulb/wet bulb 7/6℃

3. Air volume, pressure, power in the table is standard parameters. It can be separately designed according to customer`s requirements

4. Chilled water coil as optional parts, according to the customer site requirements configured to double cold source unit.

5. Heater, humidifier, heat recovery device as optional parts, according to the customer requirements configured to the other forms.

6. Unit standard uses G4 level filters, according to the customer requirements configured to the other forms.

7. Unit length does not include the function section .Such as heating section, humidification section. Specific details please consult us.

8. Air cooled split type air conditioning unit without refrigerant leaving the factory, refrigerant models need to be indicated in the order.

9. Noise data is measured 2m in front of the unit, 1.2m high, when cooling under the standard air volume.

11.Inside of bracket is R410A refrigerant type connection pipe diameter, the connection copper pipe between the indoor and outdoor unit should within 35 meters.


Our factory:


Air Conditioning Unit Reference:

Country: Turkey
Application:distributor
Type: heat pump type
Cooling capacity: 108.9KW;
Heating capacity: 113KW;
380V-3Ph-50hz
R410a
ESP: 350 Pa; 19940 m3/h
25% fresh air;
Country: Nigeria
Application: Pharmaceutical Factory
Type: heat pump type
Cooling capacity: 36.2kW
Heating capacity: 82kW
Refrigerant: R407C
Compressor: Sanyo
Country: Jordan
Application: Textile Factory
Type: heat pipe heat recovery type
Cooling capacity: 368kW
Heating capacity: 359kW
Refrigerant: R410A
Compressor: Copeland
With heat recovery coil
Country: USA
Application: Residential
Type: heat pump type
Cooling capacity: 5 Ton
Heating capacity:
Refrigerant: R410A
Compressor:
COP: 3.0
Power supply: 230V/3PH/60Hz



Country:UAE
Application:offshore Drilling Platform
Cooling capacity: 80kw
Supply air volume: 4000×2 m3/h
Condensing fan: 12000m3/h
Refrigerant: R407C
Power supply:430V-3Ph-60Hz
Evaporator & condenser type: copper tube epoxy aluminum fin
Country:Australia
Application:hall
Cooling capacity: 128kw
Heating capacity: 135kw
Capacity regulator: 0,25,50,75,100
Power supply: 415V/3PH/50hz
Refrigerant:R410A
Country:China
Application: Amusement park
Cooling capacity: 180kw
Heating capacity: 192.5kw
Supply air volume: 32000m3/h
ESP: 550pa
Power supply: 380V/3PH/50hz
Refrigerant:R22
Country: Philippines
Application: Factory
Type: Fresh air type
Cooling capacity:21.9kw
Heating capacity:25kw
Supply air volume: 3000m3/h
Electric heating: 6kw
Power supply:220v/3PH/60hz
10% fresh air
Refrigerant:R410A




Country: China
Application: Rolling bearing manufacturer
Type: wheel heat recovery type
One model:
Cooling capacity: 95kw
Condensation and heating capacity: 55kw
Supply air volume: 19000m3/h
Exhaust air volume: 19000m3/h
Another model:
Cooling capacity: 210kw
Heating capacity: 215kw
Supply air volume: 38000m3/h
Exhaust air volume: 38000m3/h
Country: China
Application:Flight simulation system laboratory
Cooling capacity:10kw
Supply air volume:3000m3/h
Power supply: 380V/3PH/50Hz

Country: China
Application:Ferry waiting hall
Type: heat pump type
Cooling capacity:182.5kw
Supply air volume: 22000m3/h
Country: China
Application: Cool Storehouse
Type: constant temperature and constant humidity unit
One model:
Cooling capacity: 22kW
Electric heating capacity: 82kW
Humidifying capacity: 6kg/h
Supply air: 4500 m3/h
Another model:
Cooling capacity: 180kW
Electric heating capacity: 90kW
Humidifying capacity: 30kg/h
Supply air: 35000 m3/h