Add to Cart
JLSF-40HP Air Cooled Water Chiller Beverage Machinery, Food Freezing, Food Refrigeration
Product Description:
Air-cooled chiller is a kind of chiller equipment, also known as chiller. It discharges heat by using an air condenser, so it is called "air-cooled", which is different from the way water-cooled chillers work, which uses a water condenser to discharge heat.
Compared with the traditional water-cooled chiller, the difference between the air-cooled chiller and the traditional water-cooled chiller is that it uses an air cooler as a condenser, and the fan blows the air required for heat dissipation from one side of the machine and exhausts it from the other side. Achieve cooling. Therefore, the air-cooled chiller does not need an external cooling water source, is independent, and is very convenient to install and move.
Product Features:
Air-cooled chiller is a common refrigeration equipment, its main features are as follows:
1.Independence: The air-cooled chiller does not need to be connected to an external cooling water source through pipes or water pumps. It is independent and easy to install and move.
2.High efficiency and energy saving: The air-cooled chiller adopts high-efficiency compressors and heat exchangers, which can reach the set temperature requirements in a short period of time, and can also reduce energy consumption and have better energy-saving effects.
3.Easy maintenance: The air-cooled chiller is simple in structure, easy to maintain, easy to clean and repair.
4.Low noise: The air-cooled chiller has low operating noise and will not interfere with the surrounding environment and personnel. It is suitable for places that require a quiet environment.
5.Automatic control: The air-cooled chiller adopts an advanced control system, which can automatically adjust the temperature and humidity to ensure stable and reliable cooling effect.
6.Flexibility: The air-cooled chiller can be used alone or in conjunction with other equipment to meet different needs.
In general, the air-cooled chiller has the characteristics of independence, high efficiency and energy saving, easy maintenance, low noise, automatic control and flexibility, and is an ideal equipment widely used in various refrigeration needs.
Working Principle:
The main components of an air-cooled chiller include a compressor, an air condenser, an expansion valve, and an evaporator. Here is a basic overview of its workflow:
1.The compressor takes in low-pressure, low-temperature refrigerant
gas and compresses it into high-pressure, high-temperature gas.
2.This high-temperature, high-pressure refrigerant gas enters the
air condenser, exchanges heat with the ambient air, and discharges
heat to the environment, while the refrigerant condenses from a
gaseous state to a liquid state.
3.The high-pressure refrigerant liquid passes through the expansion
valve, the pressure suddenly drops, and it turns into a
low-pressure and low-temperature refrigerant liquid.
4.The low-temperature and low-pressure refrigerant liquid enters
the evaporator, absorbs indoor heat, evaporates into a gaseous
state by itself, and the indoor temperature drops to achieve the
purpose of refrigeration.
5.The refrigerant gas is sucked into the compressor again to
complete a cycle.
The advantages of air-cooled chillers include simple installation, no need for cooling towers and cooling water pumps, and low maintenance costs. However, its efficiency is lower than that of water-cooled chillers, especially at high ambient temperatures, and its efficiency will be further reduced
① Compressor | ⑤ Evaporator | ⑨ Temperature sensor | ⑬ Bypass valve |
② Condenser | ⑥ Ball valve | ⑩ Water tank | ⑭ Low voltage controller |
③ Filter drier | ⑦ Antifreeze switch | ⑪ Water pump pressure gauge | ⑮ High voltage controller |
④ Expansion valve | ⑧ Float switch | ⑫ Water pump | ⑯ Pressure relief valve |
Techinical Parameters:
Model | JLSF-1HP | JLSF-2HP | JLSF-3HP | JLSF-4HP | JLSF-5HP | JLSF-6HP | JLSF-8HP | JLSF-10HP | ||
Cooling capacity | KW/h | 3.1 | 6.2 | 9.3 | 12.4 | 15.5 | 18.6 | 24.8 | 31 | |
Kcal/h | 2,700 | 5,400 | 8,100 | 10,800 | 13,500 | 16,200 | 21,600 | 27,000 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 1.21 | 2.03 | 2.84 | 3.7 | 4.5 | 5.7 | 7.33 | 8.83 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 0.75 | 1.50 | 2.25 | 3.00 | 3.75 | 4.50 | 6.00 | 7.50 | |
Circulating pump | Power | KW | 0.375 | 0.375 | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 | 1.5 |
Head | m | 22 | 22 | 22 | 22 | 23 | 23 | 23 | 21.5 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 0.50 | 1.00 | 1.50 | 2.00 | 2.50 | 3.00 | 4.00 | 5.00 | |
Evaporator | Flow | m³/h | 0.82 | 0.98 | 1.45 | 1.88 | 2.42 | 2.92 | 3.75 | 4.85 |
water capacity | m³ | 0.028 | 0.04 | 0.05 | 0.05 | 0.065 | 0.065 | 0.13 | 0.18 | |
Diameter | inch | 1/2" | 3/4" | 1" | 1-1/2" | 1-1/2" | ||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 680 | 800 | 1040 | 1140 | 1140 | 1200 | 1400 | 1400 |
W | mm | 420 | 480 | 555 | 620 | 620 | 650 | 725 | 725 | |
H | mm | 720 | 850 | 1060 | 1200 | 1200 | 1160 | 1450 | 1450 | |
Unit weight | Kg | 60 | 90 | 130 | 140 | 170 | 210 | 270 | 350 |
Model | JLSF-12HP | JLSF-15HP | JLSF-20HP | JLSF-25HP | JLSF-30HP | JLSF-40HP | JLSF-50HP | JLSF-60HP | ||
Cooling capacity | KW/h | 37.2 | 46.5 | 65 | 77.5 | 93 | 124 | 155 | 186 | |
Kcal/h | 29,059 | 37,965 | 50,805 | 61,683 | 74,992 | 97,675 | 116,521 | 156,249 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 11.4 | 13.62 | 19.8 | 22.75 | 28.3 | 39.2 | 46.75 | 56.1 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | 37.5 | 45 | |
Circulating pump | Power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 5.5 |
Head | m | 21.5 | 21.5 | 22 | 22 | 25 | 25 | 25 | 26 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 7.2 | 9.1 | 12.2 | 15.3 | 18.6 | 24.5 | 30.6 | 36.8 | |
Evaporator | Flow | m³/h | 5.81 | 7.6 | 10.16 | 12.34 | 15.2 | 19.53 | 23.3 | 30.52 |
water capacity | m³/h | 0.18 | 0.21 | 0.28 | 0.32 | 0.32 | 0.61 | 0.66 | 0.72 | |
Diameter | inch | 1.5" | 2" | 2.5" | 3" | |||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 1400 | 1750 | 2000 | 2000 | 2200 | 2000 | 2000 | 2400 |
W | mm | 725 | 750 | 900 | 900 | 900 | 1800 | 1800 | 1800 | |
H | mm | 1450 | 1500 | 1770 | 1770 | 1770 | 2200 | 2300 | 2300 | |
Unit weight | Kg | 370 | 480 | 590 | 590 | 880 | 1000 | 1280 | 1420 |
Application Industry:
In the food industry, chillers are commonly used refrigeration equipment to provide stable refrigeration effects for food production, storage, transportation and other links.
The application of chillers in the food industry mainly includes the following aspects:
1.Cooling food: Food processing needs to control the temperature, and the chiller can provide cooling for the food to ensure the quality and taste of the product.
2.Refrigerated food: Food storage needs to maintain a constant temperature and humidity, and the chiller can provide a stable cooling effect for the refrigerator and freezer.
3.Ice making: In the food industry, chillers are commonly used to provide ice making services, such as ice machines, cold drink machines, etc., to meet the needs of food production and sales.
4.Food transportation: Food transportation needs to maintain a certain temperature, and the chiller can provide refrigeration services for transportation vehicles to ensure the safety and quality of food.
In general, chillers in the food industry have a wide range of applications, and can provide stable cooling effects for food production, storage, transportation and other links, ensuring product quality and safety.
Automotive Manufacturing Chemical Engineering Electronics Industry
Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Air Cooled Chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
Product Maintenance:
Air-cooled chillers are widely used in the food industry. In order to ensure their normal operation and prolong their service life, regular maintenance and maintenance are required. The following are the maintenance and maintenance points of air-cooled chillers:
1.Clean the filter screen: The filter screen of the air-cooled chiller will accumulate dust and dirt, which will affect the cooling effect, so the filter screen needs to be cleaned every month.
2.Check the radiator: The radiator of the air-cooled chiller needs to be checked regularly to ensure that there is no dust or debris on the surface to maintain a good heat dissipation effect.
3.Check the electrical connection: The electrical connection of the air-cooled chiller needs to be checked regularly to ensure that the wires are not aged or damaged to avoid electrical failures.
4.Check the water level and refrigerant: The water level and refrigerant of the air-cooled chiller need to be checked regularly to ensure that it is within the appropriate range to ensure the cooling effect and stable operation.
5.Regular maintenance: Air-cooled chillers need regular maintenance, including replacing refrigerants, cleaning radiators, checking and replacing motor bearings, etc., to ensure their normal operation and prolong their service life.
In general, the maintenance and maintenance of air-cooled chillers in the food industry is very important, which can avoid failure and damage, and ensure the cooling effect and food safety. It is recommended to formulate a regular maintenance plan according to the usage conditions, and operate in strict accordance with the operating instructions. In case of malfunctions or problems, it is recommended to contact professional maintenance personnel in time to deal with them.