Add to Cart
CCTV DC Boxed Switching Power Supply
Key Feature:
Model: PSB1210-18
Input: AC100-240V, 50-60Hz
Output: DC12V, 10A, 18Port Channels
AC Input Plug: US,EU,UK,etc.available
Multiple Protection: Over Current/Voltage/Load (PTC Fuse)
Box Size: 31cm*21cm*6.1cm, 1.8kg/piece
Specification:
Item | 12V DC, 10A, 18 Channels Boxed CCTV Power Supply | ||
Model | PSB1210-18 | ||
Output | Voltage | 12 V | |
Current (Rated) | 10 A | ||
Power (Rated) | 120 W | ||
Output Port | 18 | ||
Ripple/Noise (Max.) | 150mVp-p | ||
Voltage (Adjust Range) | 4.75-5.5 V | ||
Voltage Accuracy | ±2.0% | ||
Line Regulation | ±1.5% | ||
Load Regulation | ±1.5% | ||
Time(Start, Rise, Hold) | 1000ms, 30ms/230VAC, 1000ms,30ms/115VAC(Full-Load) | ||
Input | Voltage (Range) | 85-264 V AC | 120-370 V DC |
Frequency (Range) | 47-63 Hz | ||
Efficiency (Typ) | 79% | 81% | |
AC Current | 0.3A/115V AC | 0.25A/230V AC | |
Surge Current | Cold boot: 40A/100V AC | 80A/230V AC | |
Leakage Current (Max) | <2mA/240V AC | ||
Protection | Over Load | Not over 105% rated output power | |
Mode: Hiccup Mode, Recover after removing the over-load | |||
Over Voltage | 5.75-6.75V | 13.8-16.2V | |
Mode: Shut down the output, Zener diode clamp | |||
Over Temperature | Protection will be triggered when the temperature of connect point inside the transistor over 140℃ | ||
Mode: Shut down the output, Auto-recover after the temperature return to normal value. | |||
Environment | Operate Temperature | -20 ~ 60 ℃ | |
Operate Humidity | 20 ~ 90%RH, no condensing | ||
Storage Temperature | -40% ~ 85 ℃ | ||
Storage Humidity | 10% ~ 95%RH, no condensing | ||
Temperature Factor | ±0.03%/℃(0 ~ 45℃) | ||
Vibration Resistance | 10 ~ 500Hz, 2G10mins/cycle, X,Y,Z axis each 60 minutes | ||
Safety & EMC | Safety Specification | UL60950-1, CB(IEC60950-1), CCC GB4943.1:2011 Approved | |
Electric Strength | I/P ~ O/P:3KVDC; I/P ~ FG:2KVDC; 0/P ~ FG:0.5KVDC | ||
Insulation Resistance | I/P ~ O/P , I/P ~ FG , 0/P ~ FG:100M Ohms/500VDC/25℃/70%RH | ||
EMC Radiation | Conform to EN55022(CISPR22) ClassB, EN61000-3-2,3 | ||
EMC Immunity | Conform to EN61000-4-2,3,4,5,6,11,EN55024,EN61000-6-1, A level QB SG | ||
MTBF | ≥563.5Khrs MIL-HDBK-217F(25℃) | ||
Note | 1. All specs and parameter, in the absence of special note, are measured base on 230VAC Input, Rate Loading, 25℃, 70%RH environment. | ||
2. Volts D.C. Measuring Method: measure at the end of plug-in terminal under 50% loading condition | |||
3. Ripple/Noise measuring method: Use a 12" twisted pair and terminal parallel connecting with 0.1uf and 47uf capacitance and measure in 20MHZ bandwidth | |||
4. Accuracy: Include assigned error, Line regulation, Load regulation | |||
5. Line Regulation Measurement: Measure range from low voltage to high voltage under rated loading | |||
6. Load Regulation Measurement: Measure range from 0% to 100% | |||
7. According to the rule GB4943.1, power supply only applicable in the place where elevation lower than 2000m and non-tropical climate area safely | |||
8. Power supply shall be deemed to be part of system components, so it has to be applied based on electromagnetic related confirmation. |