2W series 2-way direct acting ( NC ) solenoid valve 1/8" ~ 3/8"
working medium:water,liquid,air,light oil(viscosity≤20cst)
medium temperature:-5 ~ 80℃
working pressure:0 ~ 15bar (details see specification table)
working type:direct acting(NC)
valvebody material:brass SS316
sealing material:NBR
interface:G thread NPT thread
working voltage:AC220~240V AC110V 50/60Hz 22VA DC24V DC12V 13W IP65 H degree
options:
Rc thread sealing material: EPDM VITON VMQ
digital timer LED light connector ES low power energy saving coil(AC220V 3VA DC24V 3W)
2W-series 2-way direct acting(NC)specification table
(ES coil can match EPDM and VITON, but medium temperature must be ≤80℃)
Interface size | Orifice size (mm) | Cv | working pressure(bar) | medium temperature ℃ | sealing material | coil insulation degree | coil power | normal order code | ||||||
min pressure | max pressure pressure | Normal coil | Es coil | plastic seal voltage AC220V G thread sealing material:Blank: NBR E:EPDM V:VITON | ||||||||||
air gas water hotwater liquid light oil | VA | W | VA | W | ||||||||||
AC 220 V | DC 24 V | AC 220 V | DC 24 V | |||||||||||
AC | DC | brass | SS316 | |||||||||||
1/8〃 | 2.5 | 0.2 | 0 | 15 | 15 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-025-06N-AC220V | 2W-025-06JN-AC220V |
2.5 | 0.2 | 0 | 15 | 15 | 130 | EPDM | H | 22 | 13 | 2W-025-06N-E-AC220V | 2W-025-06JN-E-AC220V | |||
2.5 | 0.2 | 0 | 15 | 15 | 120 | VITON | H | 22 | 13 | 2W-025-06N-V-AC220V | 2W-025-06JN-V-AC220V | |||
3.0 | 0.25 | 0 | 12 | 12 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-030-06N-AC220V | 2W-030-06JN-AC220V | |
3.0 | 0.25 | 0 | 12 | 12 | 130 | EPDM | H | 22 | 13 | 2W-030-06N-E-AC220V | 2W-030-06JN-E-AC220V | |||
3.0 | 0.25 | 0 | 12 | 12 | 120 | VITON | H | 22 | 13 | 2W-030-06N-V-AC220V | 2W-030-06JN-V-AC220V | |||
4.0 | 0.3 | 0 | 8 | 5 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-040-06N-AC220V | 2W-040-06JN-AC220V | |
4.0 | 0.3 | 0 | 8 | 5 | 130 | EPDM | H | 22 | 13 | 2W-040-06N-E-AC220V | 2W-040-06JN-E-AC220V | |||
4.0 | 0.3 | 0 | 8 | 5 | 120 | VITON | H | 22 | 13 | 2W-040-06N-V-AC220V | 2W-040-06JN-V-AC220V | |||
1/4〃 | 2.5 | 0.2 | 0 | 15 | 15 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-025-08N-AC220V | 2W-025-08JN-AC220V |
2.5 | 0.2 | 0 | 15 | 15 | 130 | EPDM | H | 22 | 13 | 2W-025-08N-E-AC220V | 2W-025-08JN-E-AC220V | |||
2.5 | 0.2 | 0 | 15 | 15 | 120 | VITON | H | 22 | 13 | 2W-025-08N-V-AC220V | 2W-025-08JN-V-AC220V | |||
3.0 | 0.25 | 0 | 12 | 12 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-030-08N-AC220V | 2W-030-08JN-AC220V | |
3.0 | 0.25 | 0 | 12 | 12 | 130 | EPDM | H | 22 | 13 | 2W-030-08N-E-AC220V | 2W-030-08JN-E-AC220V | |||
3.0 | 0.25 | 0 | 12 | 12 | 120 | VITON | H | 22 | 13 | 2W-030-08N-V-AC220V | 2W-030-08JN-V-AC220V | |||
4.0 | 0.3 | 0 | 8 | 5 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-040-08N-AC220V | 2W-040-08JN-AC220V | |
4.0 | 0.3 | 0 | 8 | 5 | 130 | EPDM | H | 22 | 13 | 2W-040-08N-E-AC220V | 2W-040-08JN-E-AC220V | |||
4.0 | 0.3 | 0 | 8 | 5 | 120 | VITON | H | 22 | 13 | 2W-040-08N-V-AC220V | 2W-040-08JN-V-AC220V | |||
1/4〃 | 5.0 | 0.4 | 0 | 5 | 3 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-050-08N-AC220V | 2W-050-08JN-AC220V |
5.0 | 0.4 | 0 | 5 | 3 | 130 | EPDM | H | 22 | 13 | 2W-050-08N-E-AC220V | 2W-050-08JN-E-AC220V | |||
5.0 | 0.4 | 0 | 5 | 3 | 120 | VITON | H | 22 | 13 | 2W-050-08N-V-AC220V | 2W-050-08JN-V-AC220V | |||
6.0 | 0.7 | 0 | 4 | 3 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-060-08N-AC220V | 2W-060-08JN-AC220V | |
6.0 | 0.7 | 0 | 4 | 3 | 130 | EPDM | H | 22 | 13 | 2W-060-08N-E-AC220V | 2W-060-08JN-E-AC220V | |||
6.0 | 0.7 | 0 | 4 | 3 | 120 | VITON | H | 22 | 13 | 2W-060-08N-V-AC220V | 2W-060-08JN-V-AC220V | |||
3/8〃 | 4.0 | 0.3 | 0 | 8 | 5 | 80 | NBR | H | 22 | 13 | 3 | 3 | 2W-040-10N-AC220V | 2W-040-10JN-AC220V |
4.0 | 0.3 | 0 | 8 | 5 | 130 | EPDM | H | 22 | 13 | 2W-040-10N-E-AC220V | 2W-040-10JN-E-AC220V | |||
4.0 | 0.3 | 0 | 8 | 5 | 120 | VITON | H | 22 | 13 | 2W-040-10N-V-AC220V | 2W-040-10JN-V-AC220V |
Water solenoid valve use and maintenance:
1, it is recommended to use the unit to send the person responsible
for maintenance.
2, the solenoid valve is installed into the media need to pass
several experimental action shall be put into use after confirming
normal.
3, large internal and external valve should be cleaned regularly
and the title of the pull side of the dirt, careful not to damage
the sealing surface.
4, when the solenoid valve is a long time to do, should be closed
before the valve manual valve, when re-enabled, steam solenoid
valve should condensate removal and clean, and make trial action
several times, only to be put into use after the switch to normal.
5, when the solenoid valve from the pipeline do not remove, the
internal parts should be scrubbed and blowing with compressed air
storage.
6, when used for a long time, such as a seal between the piston and
the valve seat is bad, the piston sealing surface re-polished, and
now seat grinding.
7, in operation, should pay attention to before and after the valve
pressure gauge required working pressure must not exceed the rated
pressure, working pressure must be within the rated pressure range.
When the operating pressure exceeds the rated pressure or working
pressure exceeds the rated pressure, the solenoid valve to stop
using closed before and after manual valves, solenoid valves to
prevent explosions and leaks.