120A DC Telecom Rectifier System , Single Phase / Three Phase Rectifier


Quick Details:


Place of Origin: Shenzhen, China (Mainland)Input Voltage: AC220V
Brand Name: ESTELOutput Voltage: DC48V
Model Number: GPE48120COutput Power: 6400W
Product Name: Telecom Power SystemInput Frequency 50Hz
Certification: ISO9001, CE, 3C, FCC, TLCMax. Input Current: 20A
Installation Mode: 19” cabinetPower Factor: 0.99
Application: outdoor telecom cabinet

Components:

4×30A rectifier module,

1×monitoring module,

power distribution


Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C, D/A, D/P, T/T, Western Union
Supply Ability:20,000 sets per month
Delivery Time:7-10 working days
Packaging Details:carton/wooden case

1. System Configuration


The system consists of power distribution unit, rectifier module (from 1 set, up to 5 sets) and 1 monitoring module. The configuration is optional, as following table:


ConfigurationRectifier ModuleMonitoring ModulePower DistributionRemark
StandardGPR4830A1GPM48R (With Ethernet Port)

AC power distribution: AC input is wire connection terminal;

DC power distribution: battery MCB 100A×2;

LVLD: 63A×2 32A×4 (MCB capacity optional)

LVBD: 16A×2 (MCB capacity optional)

For details, please refer to the specifications of modules.

2. Operating Principle


AC power is first input AC-INPUT MCB and then feed into the rectifier module after lightning proof and filtering. AC-INPUT acts as protection to over load and short circuit to AC power. The user’s battery is connected to the DC output side through MCB BAT and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.

Under normal conditions, every parameter of rectifier modules and power distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains faults, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When battery voltage is under -47V±0.5V, the monitoring module sends DC under voltage alarm signal and when battery voltage is under -46.0V±0.5V (adjustable), the KM1cuts off non-priority loads and retains power to priority loads. If battery voltage drops to -43.0V±0.5V (adjustable), the KM2 will cut off output of priority loads and then the power system will stop working. If the external AC mains recovers, the system will normally work again. (All above monitoring data are system default values and can be reset by user).


Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding.


3. System Property


Environment
ItemMin.TypicalMax.UnitRemark
Operating temperature-2555°CWhen ≥55°C, decreased power output
Storage temperature-4080°C
Humidity1090%Relative humidity without condensing
Atmospheric pressure70106KPa
Altitude03000m
CoolingForced cooling with fan

Input
ItemMin.TypicalMax.UnitRemark
Input voltage range90220280Vac
Input frequency455065Hz
Max. Input current20A
Power factor0.99Rated load
Input over voltage protection point285VacAutomatically recoverable
Input over voltage recovery point280VacReturn difference ≥5V
Input under voltage protection point85VacAutomatically recoverable
Input under voltage recovery point90VacReturn difference ≥5V
Input over current protection

Output (Table 1)
ItemMin.TypicalMax.UnitRemark
Output voltage4253.558VdcAdjustable by monitor, tested in no load
Output power6400W176~280VAC (rated power includes battery charging power plus load power)
3200W90~175VAC input
Output over voltage protection point58.561.5VdcLock up
Output current limiting protection pointOutput current limiting protection
Output short circuit protectionLong-term short circuit protection, automatically recoverable
Over temperature protectionAutomatically recoverable in ambient temperature lower than 65°C
Battery power-down protectionBattery power-down protection
Battery polarities reversal connection protectionNo damage on battery and power system
Voltage regulation accuracy±1%

Output (Table 2)
ItemMin.TypicalMax.UnitRemark
Temperature coefficient±0.2‰/℃
Current sharing unbalance±5%Within 50~100% load range
Start-up/shut-down overshoot range±5%Any module is removed when operating, (the load current should be less than total output current of working rectifier modules), the system output voltage fluctuates
Dynamic response recovery time200uS

25%~50%~25% load variation

50%~75%~50% load variation

Dynamic response overshoot±5%Rated output voltage, rated load current
Efficiency9091%220Vac input, rated output voltage, rated load current
83%110Vac input, rated output voltage, rated load current
Start-up time38Spre-current limiting is fitted with start-up output between rated start up input voltage and rated output voltage established period
Peak-peak noise voltage200mV

Other Parameters
ItemRequirement
Acoustic noise≤55dB(A)
Smellingany abnormal and poisonous smelling is not allowed
Componentsrated temperature of the electrolytic capacitor ≥105℃
Hot swappablethe rectifier module meets the hot-swappable requirement
Mixed insertionrectifier modules can be mixed insertion
Ineffective separationrectifier module can separate with system when it is ineffective
Coolingforced cooling by fan mounted on rectifier, face in, back out. The fan is mounted on rectifier front panel; can be disassembled. Fans include temperature control speed adjusting function.

Insulation Rating
ParametersMin.TypicalMax.UnitRemark
Input-chassis4242Vdc
Input-output2121Vdc
Output-chassis750Vdc
Insulating ResistanceIn normal atmospheric pressure, when relative humidity is 90%, testing voltage is 500VDC, the insulating resistance of input-output, input-grounding, output-grounding are all ≥10MΩ

4. Dimension


Mechanical specifications
Dimensions (mm)as the following diagram
Weight(kg)

≤18kg (Inclusive of module)

≤10kg (Frame + Distribution, exclusive of module)



5. Electrical Connection


Chassis connects with external electric through system interface board. As shown in figure below:



Power Distribution Instruction:

  • Grounding Screw
  • AC Input MCB
  • Battery MCB (100*2)
  • SPD
  • LOAD(-): System Load Cathode LVLD (6 MCBs)
  • LOAD(-): System Load Cathode LVBD (2 MCBs)
  • Monitoring Module
  • LOAD(+): System Load Anode (Copper Bar On Front Panel Of The System)
  • Rectifier Module

6. GPE48120C Distribution Frame



7. Application


(1) Small scale program controlled exchanger

(2) Access network

(3) Transmission equipment

(4) Mobile communication

(5) Satellite communication ground station

(6) Microwave communication

8. Features


(1) Adoption of active power factor compensation technology with factor >0.98

(2) Wide operating range of AC input voltage: 90~290Vac

(3) Operating temperature range: -25°C~+55°C

(4) Zero current/voltage switching tech with high efficiency ≥91%

(5) Lifecycle of battery prolonged by perfect battery management, including electrical charge/discharge management, battery temperature compensation, battery capacity test, reversal connection proof protection, low voltage protection etc.

(6) Hot-swappable

(7) Input over/under voltage protection

(8) Output over voltage protection

(9) Output over current protection

(10) Output short circuit protection

(11) Auto current sharing, parallel output

(12) Embedded mounting


9. Packing and Shipping




Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

10. Our Contact Information

Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

China 120A DC Telecom Rectifier System , Single Phase / Three Phase Rectifier supplier

120A DC Telecom Rectifier System , Single Phase / Three Phase Rectifier

Inquiry Cart 0