Product Details

AC440-1200KW 3 Phase Load Bank With Best Sales And High Performance

Introduction

(1) According to the special requirements of users on site, in the agreement the technical standards of AC440-1200KW Resistive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator, UPS load test.

(2) The system consists of 1 sets of 1200KW Resistive load bank. The resistive power is 1200KW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.

Applications
This system, which is of independent research and development of electricity load test equipment by our technology, combining dry load module with the automatic measurement and control module, can accurately detect all kinds of generator output power and load capacity, full load and overload test.
The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, comprehensively from the cumbersome manual operation to provide scientific and efficient detection means for the power generating sets.
All the schematic diagrams of this agreement are for reference only please in kind prevail

Technical specification

System Parameter
Rating voltage/frequency440V 3 phase 4 wire,wire voltage: 440V, phase voltage: 254V, 50HZ/60HZ
Max Load PowerResistive Load: 1200kW
Load Resolution

Resistive Load: 14 steps,

1kW,2KW,2kW,5kW,10kW,10kW,20kW,50kW,100kW, 200kW,200kW,

200kW,200kW,200kW

Power Factor1
Load Tolerance (each step)±5%
Load Tolerance (overall)±3%
Fan &Control VoltageExternal 380V 3 phase 4 wire, wire voltage: 380V, phase voltage: 220V, 50HZ
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication InterfaceRS485,RS232
InsulationF
Max Protection GradeIP54
Duty CycleContinuous
CoolingForced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
EnclosureContainer type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal LightingAdequate internal lighting will be provided
TransportationHoisting, there are lifting lug in top of casing
ColorGrey RAL7035 or as required
DimensionsAbout 3000mm*2350mm*2591mm(L×W×H)
Operating Environment Parameter
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%
Atmospheric Pressure86~106kPa
Brands of Main Components
ContactorSchneider
FuseMiro
PLCSiemens
Alloy Resistor(self-developing)
Data Processing Software(self-developing)
Main features

Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.

New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.

Standard Testing Function: System can do stable test, transient test, and realize functions, such as setting, fluctuation, instant load, and instant unload. The terms and formulas used in test strictly comply with relevant national standard.

High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.

Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.

High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.


China 14 Steps Gray 3 Phase Load Bank Continuous Working With 254 V Phase Voltage supplier