Product Details

Safety Testing System / Desktop Type Safety Tester


1. Introduction

  • High voltage/Hipot/ dielectric strength:

As a requested test by the international safety certification organization, Hipot must be performed to ensure the products electrical safety. The testing method is to apply the voltage higher than the normal working voltage to the product for a while, and check whether there is bad insulation condition.

  • Insulation resistance test

Apply DC voltage (up to 1000 volt) to the concerned two terminals and check the insulation. Normally the unit of the tested resistance is Ohm.

  • Ground impedance test

Ground impedance test is to test the grounding terminal of the tested products. Apply a certain current to the product case or metal part and check the impedance of two terminals. Normally the impedance should be less than 0.1 ohm if the applied current is 25A. According to the requirement of CSA, the loose screw on ground terminal, ground lead small diameter and ground lead disconnection will be tested under 40A.

  • Leakage current test

Leakage current test is the current that go through the touchable metal part and human body to the ground. It is the current of the touchable part on the product.

  • Power test

The purpose of power test is to test whether the input circuit can withstand the current required when the product is in normal operation. It is stipulated in the product standard that the input current of the maximum power consumption shall not be greater than 110% of the product's nominal value. This nominal value also tells the user the minimum current required for the product's safety work, and reminds the user to prepare such an electrical environment before using the device.


2. Features

The safety testing system supports to test both the safety and power, providing 2-channel test power input and solve the problem of power switch caused by the voltage inconsistency of leakage current test and power test. Optional equipped with the USB port for testing data save and export.


3. Technical parameter

Test item

AC Hipot, DC Hipot, Insulation resistance, Grounding resistance, leakage, power

Data save mode

USB save

AC Hipot

Output voltage setting range/ precision

AC 200~5000V ±(3%×setting value+5 words)

Breakdown current testing range/ precision

0.10~25.00mA ±(3%×display value+5 words)

Breakdown current presetting alarm range

Max:0.10~25.00mA ;Min:0.00~5.00mA

Test time range/ resolution

1~300s 1s/step

Insulation resistance

Output voltage setting range/ precision

DC 500/1000V ±(3%×reading +5 words)

Insulation resistance testing range / precision

1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8words)

Insulation resistance alarm setting range

Max:0~2000MΩ;Min:1~2000MΩ

Test time range/ resolution

1~300s 1s/step

Grounding resistance

Grounding current output range/ precision

AC 5.0~30.0A ±(3%×setting value +5 words)

Grounding resistance testing range/ precision

10.0~600mΩ ±(3%×display value+5 words)

Grounding resistance alarm setting range

Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;

Min:0.0~100mΩ

Test time range/ resolution

1~60s 1s/step

Power

Output voltage

1.0 times rated voltage

Output voltage testing range / precision

AC 50~280V ±(0.5%×display value+2words)

Output current testing range / precision

AC 0.20~30.00A ±(0.5%×display value+2words)

Active power testing range / precision

30~6000W ±(0.5%×display value+5words)

Multi-position setting

4 positions can be set, identify position switch automatically, each position can display corresponding test data after complete the test.

Power setting alarm range

Max:3~6000W Min:0~6000W

Test time range / resolution

1~300s 1s/step

Leakage

Output voltage

1.06 times rated voltage

Leakage type setting

Dynamic leakage, static leakage ,optional equipped with 3 types of body network ,,which can be customized and switched freely.

Output voltage testing range / precision

AC 50~280V ±(0.5%×display value+2words)

Leakage current test range/ precision

0.05~20.00mA ±(1.5%×display value +0.02mA)

Leakage current setting alarm range

Max:0.05~20.00mA;Min:0.01~5.00mA

Test time range

1~300s 1s/step


4. Feature

  • Integrated Hipot, insulation resistance, grounding, leakage, and power test.
  • High efficiency: complete all test items in 6 seconds.
  • Save manpower: reduce the labor cost of traditional single tester with multiple workers.
  • Application: widely used in home appliance, and electrical appliance.
  • Information: optional equipped with USB data port to export testing data.