Home /IPL Machine /

Arm SHR elight Hair Removal Machine Skin Rejuvenation / freckle Removal Machine

Arm SHR elight Hair Removal Machine Skin Rejuvenation / freckle Removal Machine

Brand Name:XYY
Certification:CE ,ISO, TUV
Model Number:SR-07
Minimum Order Quantity:1 set
Delivery Time:3-5 working days
Payment Terms:T/T, Western Union, MoneyGram,paypal
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Room 308,Building 3, POP Center,Xinghua Street,Daxing District, Beijing, China
Supplier`s last login times: within 2 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Arm SHR elight Hair Removal Machine Skin Rejuvenation / freckle Removal Machine


Technical parameter of elight machine


Wavelength

430nm/530nm/560nm/590nm/640nm-1200nm

Handpiece number

2 piece with 5 filters

Spot size

12*30(mm) &15*50(mm)

Cooling system

semiconductor+air+water+cooling gel

IPL light energy

1-50(j/cm²)

Pulse duration

1-10ms

Pulse NO.

1-6

SHR pulse duration

1-7ms

SHR frequency

1-10HZ

SHR energy

1-50J/CM2

Skin cooling

-4°c-10°c

Display

10.4″color touch screen

Output power

2500W

Voltage

110v,50hz or 220v,60hz

Machine Size

(L*W*H):42cm*38cm*90cm

Net weight

60kg

Gross weight

91kg

Package size

69cm*64cm*102cm


Hair removal of OPT elight machine


1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
2. Clear treatment area.
3. Turn on machine,
1). Use SHR, adjust pulse width at 7ms, frequency 5HZ, energy 10J/cm2.
2). Use normal hair removal treatment, put the 640nm or 690nm filter into the slot, select
"hair removal",adjust the parameter, set it to ‘ready’ .
4. Put cooling gel on treatment area about 2mm.
5. Wear protect goggles for patient and operator.
6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have
1/3 overlapping on treatment area.
7. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area until heat disappear.


Skin rejuvenation


1. Clear treatment area.
2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.


Pigmentation Therapy


1. Clear treatment area.
2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
therapy",adjust the parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.


Vascular Therapy


1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.


Acne Therapy


1. Clear treatment area.
2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.

Wrinkle removal

1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
parameter, set it to ‘ready’ .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4°C.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.



shr ipl Theory:


SHR refer to Super Hair Removal, it’s a revolutionary technology of hair removal, which is having a sweeping success. SHR combines laser technology and the benefits of the pulsating light method achieving practically painless results. SHR combined with "In Motion" represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than the traditional IPL system and your skin is better protected.

SHR gently transports the energy through the skin and through the melanin to the hair follicles. Research has shown that a slower, but longer heating process is considerably more effective for permanent hair removal than high and short levels of energy. Therefore, when using SHR, the device is passed over the tissue multiple times (in motion) using low energy but a high rate of repetition (up to 8Hz, i.e. 8 times per second) instead of using the traditional method with single, high-energy impulses. Thus, the hair melanin, as well as the tissue of the stem cells, is heated with low energy at a slow pace and over a longer period of time to a comfortable temperature.



China Arm SHR elight Hair Removal Machine Skin Rejuvenation / freckle Removal Machine supplier

Arm SHR elight Hair Removal Machine Skin Rejuvenation / freckle Removal Machine

Inquiry Cart 0