Home /Power Distribution Equipment /

Professional Fire Testing Equipment ASTM D3638-92 DIN 53480 Low Voltage Tracking Testing Equipment

Professional Fire Testing Equipment ASTM D3638-92 DIN 53480 Low Voltage Tracking Testing Equipment

Brand Name:HTI
Certification:IEC60112:2003, UL746A,ASTM D 3638-92,DIN 53480, GB4706.1, GB4207
Model Number:HTB-034
Minimum Order Quantity:1 set
Delivery Time:10 working days
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Dongguan Guangdong China
Address: No. 1,Tech 9th Road,High & New Tech Development Zone,Songshan Lake,DongGuan City,Guangdong Province
Supplier`s last login times: within 26 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Professional ASTM D3638-92 DIN 53480 Low Voltage Tracking Testing Equipment


Description:


ASTM D3638-92 low voltage tracking tester simulates wet/moisture condition, test tracking index(CTI) and anti tracking index(PTI). It is used for electrical electronic products, solid insulating materials of household electrical appliance and other products.


Test method:


On the surface of solid insulate material, at the ruled 2mmx5mm platinum electrode, exert a certain voltage and set 30s time, drip the ruled drop volume(0.1%NH 4CL) at 35 mm height, then evaluate solid insulation material surface under combined electric field and medium pollution tolerance ability, determine its tracking index(CTI) and anti tracking index(PTI).


Test standard:


IEC60112:2003, UL746A,ASTM D 3638-92,DIN 53480, GB4706.1, GB4207 and other equivalent test standard.


Specifications:


1. Electrode material: platinum/stainless steel

2. Electrode size: (2mm±0.1mm)x(5mm±0.1mm)x(40mm±5mm), platinum electrode 12mm, 30°±2° cant

3. Electrode distance: 4.0mm±0.01mm, angle 60 °±5°

4. Electrode pressure: 1.00N±0.001N

5. Test solution resistance: solution A 0.1%NH 4CI, 3.95±0.05 Ω.m, solution B 1.98±0.05 Ω.m

6. Drop volume: 20 drops 0.380~0.480g, 50 drops 0.997~1.147g(adjustable)

7. Drop height: 35mm±5mm(adjustable)

8. Drop time: 30s±10.1s, digital display, preset, 50 drops time 24.5min±2min

9. Drop quantity: 1-9999, digital display, preset

10. Test wind speed: 0.2m/s

11. Test voltage: 100V~1000V(25V scale division, adjustable)

12. Power voltage drop: 8% when 1.0A±0.1A

13. External chamber dimension: 600Wx1000Hx500D mm

14. Air outlet diameter: 100mm

15. Power supply: AC 1 phase 220V 50/60Hz 500W