OBV6 series surge protection device for lightning protection

OBV6 series surge protection device for lightning protection

Brand Name:Singi
Certification:CE/CB/ISO9001/CCC
Model Number:SPD
Minimum Order Quantity:500pcs
Delivery Time:normally 15 days after deposit
Payment Terms:T/T,L/C,Western union
Contact Now

Add to Cart

Active Member
Address: NO.161 JINGQI ROAD YUEQING ECONOMIC DEVELOPMENT ZONE, YUEQING,ZHEJIANG,CHINA
Supplier`s last login times: within 31 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

OBV6 series surge protection device for lightning protection


Product Description


Surge Protection for Solar Photovoltaic (PV) System
The OBV6 series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks. These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The OBV6-B+C40 series is available for the main operating voltages in photovoltaic: 1000 Vdc.
emDC SURGE PROTECTIVE DEVICE
CodeFSP-D40
Pole2P3P
Voltage500VDC,600VDC800VDC,900VDC,1000VDC
In(8/20)us(KA)20KA
Imax(8/20)us(KA)40KA
StandardIEC/EN61643
TypeII
Characteristic CurveB,C,D
Working Temperature“-5°”to +40°
Protection DegreeIP20
Electrical lifeMore than 8000times
Mechanical lifeMore than 2000times
Dimension(W)X(H)X(D)36x90x6854x90x68
Installation35MM DIN RAIL
AccessoryRemote signal
Installation Altitude≤2000M


Installation instructions


1. You must cut off the power supply before installation, live line work is strictly prohibited.

2. In protecting front line fuse or automatic circuit breaker.

3. Protector for the parallel installation, Kevin connection is recommended (for Kevin wiring convenience, operates two terminals on the module, which is a straight up. Kevin v-like connection is a connection. A contact point and the two lines in parallel, one into, a calculated). Connector requires solid and reliable, and short, thick and straight.

4. When installed according to the installation diagram shows the connection, where l (L1, L2, L3) for the line, n is neutral, PE ground wire, do not mistake. After the installation is complete, check that the protection unit is plug in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

5. Protector in use during the fault display window should periodically verify and view state when red fault display window or remote Terminal outputs alarm signals, the protector fails, should be repaired or replaced in a timely manner.


Excellent Quality


We approvals of CE,CB,UL,ETL,CCC and ISO9001 Quality System Certificate etc.Products being popular around the world,such as Europe,America,Southeast Asia,Middle East,Africa,etc.


Competitive Price


OEM or ODM projects are fully accepted,with the quantity added step by step,the discount will be good.


Fast Delivery


With the projects or order received,the order must to be discussed in the R & D section about 2 days to deal with the parameter,then pass the order to the production section.


After-sales Service


All kind of products have quality guarantee,also after-sales worker 24h on line to solve the questions.