Home /Diesel Generators /

0.8 Power Factor Perkins Engine Generator , 2306C-E14TAG2

0.8 Power Factor Perkins Engine Generator , 2306C-E14TAG2

Brand Name:GSKA
Model Number:JPP400E1
Minimum Order Quantity:20-30 pieces
Delivery Time:3-5 days on receipt of official sales contract
Payment Terms:L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

1. Standby power: 320.0 KW

2.Engine Make & Model: Perkins 2306C-E14TAG2

3.Alternator Model: LL6014D

4.Cycle: 4 Stroke

5.Induction: Turbocharged Air To Air Charge Cooled

6.Cooling Method: Water Governing

7.Type: Electronic Governing

8.Class: ISO 8528 G2

9.Compression Ratio: 15.9:1

10.Displacement: l (cu.in) 14.6 (890.9)

11.Bore/Stroke: mm (in) 137.0 (5.4)/165.0 (6.5)

12.Moment of Inertia: kg m² (lb. in²) 3.43 (11721)


0.8 Power Factor Perkins Engine Generator , P400E1


Output Ratings

Generating Set Model


- P400E1

Prime* Standby*


380-415V, 50 Hz


  • 400.0 kVA
  • 320.0 kW

480V, 60 Hz


  • 438.0 kVA
  • 350.4 kW
  • Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.


Technical Data

Engine Make & Model:

Perkins 2306C-E14TAG2

Alternator Model:

LL6014D

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 1800

Fuel Tank Capacity: litres (US gal)

820 (216.6)

Fuel Consumption: - l/hr (US gal/hr)

- -

Fuel Consumption: P400E1 l/hr (US gal/hr)

85.1 (22.5) 91.3 (24.1)

P400E1


Physical Data Air System

Manufacturer: Perkins

Model: 2306C-E14TAG2

No. of Cylinders/Alignm 6 / In Line

Cycle: 4 Stroke

Induction: urbocharged Air To Air Charge Cooled

Cooling Method: Water

Governing Type: Electronic Governing

Class: ISO 8528 G2

Compression Ratio: 15.9:1

Displacement: l (cu.i) 14.6 (890.9) Bore/Stroke: mm (in) 137.0 (5.4)/165.0 (6.5) Moment of Inertia: kg m² (lb. in²)

3.43 (11721)

Engine Electrical System:

-Voltage/Ground: 24/Negative

-Battery Charger Amps: 70

Weight: kg (lb)

- Dry: 1690 (3726)

- Wet: 1792 (3951)


Air Filter Type:Replaceable Element combustion

Air Flow:

m³/min (cfm)

-Standby: 26.8 (946) 41.6 (1469)

-Prime: - -

Max. Combustion Air Intake

Restriction: kPa (in H2O)6.2 (24.9) 6.2 (24.9)

Radiator Cooling Air Flow:

m³/min (cf 444.0 (15680) 600.0 (21189)

External Restriction to

Cooling Air Flow: Pa (in H2O)

188 (0.8) 188 (0.8)

Cooling 50 Hz 60 Hz

Cooling System Capacity:

l (US gal) 47.0 (12.4) 47.0 (12.4)

Water Pump Type: Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby: 134.9 (7672) 153.2 (8712)

-Prime: - -

Heat Radiation to Room:

kW (Btu/min)

-Standby: 39.0 (2218) 45.3 (2576)

-Prime: - -

Radiator Fan Load: kW (hp) 9.0 (12.1) 17.0(22.8)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).


Performance 50 Hz 60 Hz


Engine Speed: RPM

1500 1800

Gross Engine Power: kW (hp)

-Standby: 353.0 (473.0) 393.0 (527.0)

-Prime: 313.0 (420.0) 365.0 (489.0)

BMEP: kPa (psi)

-Standby: 1935.0 (280.7) 1795.0 (260.4)

-Prime: 1716.0 (248.9) 1667.0 (241.8)

Regenerative Power: kW

27.0 39.0

LubriCAT-parts-partsion System


Oil Filter Type: Eco, Full Flow

Total Oil Capacity l (US gal): 68.0 (18.0)

Oil Pan l (US gal): 60.0 (15.9)

Oil Type: API CG4 15W-40

Cooling Method: Water

Fuel System


Fuel Filter Type: Eco Replaceable Element Recommended

Fuel: Class A2

Diesel Fuel Consumption: l/hr (US gal/hr)


110% 100% 75% 50% Load Load Load Load

-


50 Hz - - - -

60 Hz - - - -


P400E1


50 Hz 85.1 (22.5) 64.0 (16.9) 44.5 (11.8)

60 Hz 91.3 (24.1) 70.9 (18.7) 50.1 (13.2)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Exhaust System 50 Hz 60 Hz

Silencer Type: Level 1

Silencer Model & Qty: SD150 (1) Pressure Drop Across

Silencer System: kPa (in Hg)

0.01 (0.003) 0.06 (0.018)

Silencer Noise Reduction

Level: dB 19 17

Max. Allowable Back

Pressure: kPa (in. Hg)

7.0 (2.1) 7.0 (2.1)

Exhaust Gas Flow: m³/min (cfm)

-Standby:66.6 (2352) 95.7 (3380)

-Prime: -

- Exhaust Gas Temperature: °C (°F)

m³/min (cfm)

-Standby: 494 (921) 389 (731)

-Prime: - -

P400E1


Alternator Performance Data



Data Item

50 Hz 60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V


Motor Starting Capability* kVA


882


827


755


976


969


641


754


703


833


Short Circuit Capacity** %


300


300


300


300


300


300


300


300


300


Reactances: Per Unit


Xd X'd X''d


3.130


0.140


0.111


3.370


0.150


0.120


3.730


0.170


0.132


2.780


0.120


0.099


3.070


0.140


0.109


4.900


0.220


0.174


4.090


0.180


0.145


4.420


0.200


0.157


3.650


0.160


0.130


Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.


Alternator Technical Data


Physical Data Operating Data


Manufacturer: FG WILSON


Overspeed: RPM 2250


Model: LL6014D


Voltage Regulation (steady state) (%): + /- 0.5


No. of Bearings: 1


Wave Form NEMA = TIF: 50


Insulation Class: H


Wave Form IEC = THF: 2.0%


Winding Pitch Code: 2/3 - 6


Total Harmonic Content LL/LN: 4.0%


Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6


Ingress Protection Rating: IP23


Radiant Heat: kW (Btu/min)


-50 Hz: 23.0 (1308)


-60 Hz: 24.4 (1388)


Excitation System: SHUNT


AVR Model: R448

P400E1


Technical Data


3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM



Voltage Prime Model Standby Model Voltage Prime Model Standby Model

- P400E1 - P400E1


kVA kW

kVA kW


kVA kW

kVA kW

415/240V

- -

400.0 320.0

480/277V

- -

438.0 350.4

400/230V

- -

400.0 320.0

220/127V

- -

438.0 350.4

380/220V

- -

400.0 320.0

380/220V

- -

437.0 349.6

230/115V

- -

400.0 320.0

240/120V

- -

438.0 350.4

220/127V

- -

400.0 320.0

230/115V

- -

438.0 350.4

220/110V

- -

400.0 320.0

440/254V

- -

438.0 350.4

200/115V

- -

400.0 320.0

220/110V

- -

437.0 349.6




208/120V

- -

438.0 350.4




230/115V

- -

438.0 350.4


Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).



Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.




Weights and Dimensions


Weights: kg (lb) Dimensions: mm (in)


Net (+ lube oil)


3300 (7275)


Length


3601 (141.8)

Wet (+ lube oil & coolant)

3350 (7385)

Width

1150 (45.3)

Fuel, lube oil & coolant

4043 (8913)

Height

2065 (81.3)


General Data

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


Warranty

All equipment carries full manufacturer's warranty.


China 0.8 Power Factor Perkins Engine Generator , 2306C-E14TAG2 supplier

0.8 Power Factor Perkins Engine Generator , 2306C-E14TAG2

Inquiry Cart 0