Product Details

1. Standby power : 28.0 kw

2.Engine Make & Model: Perkins 404C-22G2 HS

3.Alternator Model: LL1012P

4.Induction: Naturally Aspirated

5.Cooling Method: Water Governing

6.Type: Mechanical Governing

7.Class: ISO 8528 G2

8.Compression Ratio: 23.3:1

9.Displacement: l (cu.in) 2.2 (135.2)

10.Bore/Stroke: mm (in) 84.0 (3.3)/100.0 (3.9)

11.Moment of Inertia: kg m² (lb. in²) 1.10 (3759)


1500 RPM Perkins Engine Generator , 404C-22G2 HS


Output Ratings

Generating Set Model

JPPH35E2

Prime* Standby*

380-415V, 50 Hz

* 35.0 kVA

* 28.0 kW

220/127V, 60 Hz

* *

* *

  • Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.



Technical Data

Engine Make & Model:

Perkins 404C-22G2 HS

Alternator Model:

LL1012P

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 *

Fuel Tank Capacity: litres (US gal)

45 (11.9)

Fuel Consumption: P12.5P2 l/hr (US gal/hr)

* *

Fuel Consumption: P13.5E2 l/hr (US gal/hr)

10.1 (2.7) *

PH35E2


Engine Technical Data


Physical Data


Manufacturer: Perkins

Model: 404C-22G2 HS

No. of Cylinders/Alignment: 4 / In Line

Cycle: 4 Stroke

Induction: Naturally Aspirated

Cooling Method: Water

Governing Type: Mechanical

Governing Class: ISO 8528 G2

Compression Ratio: 23.3:1

Displacement: l (cu.in) 2.2 (135.2)

Bore/Stroke: mm (in) 84.0 (3.3)/100.0 (3.9)

Moment of Inertia: kg m² (lb. in²) 1.10 (3759)

Engine Electrical System:

-Voltage/Ground: 12/Negative

-Battery Charger Amps: 55

Weight: kg (lb)

- Dry: 218 (481)

- Wet: 234 (517)


Air System 50 Hz 60 Hz


Air Filter Type: Replaceable

Element Combustion Air Flow:m³/min (cfm)

-Standby: 2.9 (102) -

-Prime: -

- Max. Combustion Air Intake

Restriction: kPa (in H2O) 6.4 (25.7)

- Radiator Cooling Air Flow:m³/min (cfm) 71.0 (2507)

- External Restriction to

Cooling Air Flow: Pa (in H2O) 125 (0.5)


Cooling System 50 Hz 60 Hz


Cooling System Capacity:l (US gal) 6.8 (1.8)

- Water Pump Type: Centrifugal

Heat Rejected to Water &Lube Oil: kW (Btu/min)

-Standby: 33.5 (1905)

-Prime: -

- Heat Radiation to Room:

kW (Btu/min)

-Standby: 13.2 (751)


Cooling System 50 Hz 60 Hz


Cooling System Capacity:l (US gal) 6.8 (1.8)

- Water Pump Type: Centrifugal Heat Rejected to Water &

Lube Oil: kW (Btu/min)

-Standby: 33.5 (1905) -

-Prime: -

- Heat Radiation to Room:

kW (Btu/min)

-Standby: 13.2 (751) -


Performance 50 Hz 60 Hz

Engine Speed: RPM 3000

- Gross Engine Power: kW (hp)

-Standby: 34.4 (46.0)

-Prime:

- BMEP: kPa (psi)

-Standby: 1242.0 (180.1)

-Prime:

- Regenerative Power: kW 19.0



LubriCAT-parts-partsion System


Oil Filter Type: Spin-On, Full Flow

Total Oil Capacity l (US gal): 10.6 (2.8)

Oil Pan l (US gal): 8.9 (2.4)

Oil Type: AP1CH4 15W-40

Cooling Method: Water


Fuel System


Fuel Filter Type: Replaceable Element Recommended

Fuel: Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)


110% 100% 75% 50%

Load Load Load Load

-


50 Hz - - - -

60 Hz - - - -

PH35E2


50 Hz 10.1 (2.7) 7.9 (2.1) 6.2 (1.6)

60 Hz - - -


(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


Exhaust System 50 Hz 60 Hz


Silencer Type: Level 1

Silencer Model & Qty: MXC0996 (1)

Pressure Drop Across

Silencer System: kPa (in Hg) 6.00 (1.772)

- Silencer Noise Reduction

Level: dB 27.6

- Max. Allowable Back

Pressure: kPa (in. Hg) 10.2 (3.0)

- Exhaust Gas Flow: m³/min (cfm)

-Standby: 8.5 (300)

-Prime:

- Exhaust Gas Temperature: °C (°F)

m³/min (cfm)

-Standby: 570 (1058)

-Prime:

PH35E2


Alternator Performance Dat


Data Item

50 Hz 60 Hz

415/240V

400/230V

380/220V

Motor Starting Capability* kVA

83

78

72

Short Circuit Capacity** %

0

0

0

Reactances: Per Unit


Xd

X'd

X''d


3.410

0.080

0.037


3.680

0.080

0.039


4.070

0.090

0.044


Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.


Alternator Technical Data


Physical Data Operating Data


Manufacturer: FG WILSON


Overspeed: RPM 4500

Model: LL1012P

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF: 50

Insulation Class: H

Wave Form IEC = THF: 2.0%

Winding Pitch Code: 2/3 - 6

Total Harmonic Content LL/LN: 4.0%

Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6

Ingress Protection Rating: IP23

Radiant Heat: kW (Btu/min)

-50 Hz: 4.0 (227)

-60 Hz: -

Excitation System: SHUNT

AVR Model: R230

PH35E2


Technical Data


3 Phase Ratings and Performance at 50 Hz, 3000 RPM

3 Phase Ratings and Performance at 60 Hz,

- RPM


Voltage Prime Model Standby Model Voltage Prime Model Standby Model

PH35E2 - -


kVA kW

kVA kW

kVA kW

kVA kW

415/240V

- -

35.0 28.0



400/230V

- -

35.0 28.0



380/220V

- -

35.0 28.0




Definitions


Standby Rating


These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.



Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.



Weights and Dimensions


Weights: kg (lb) Dimensions: mm (in)



Net (+ lube oil)


461 (1016)


Length


1320 (52.0)

Wet (+ lube oil & coolant)

468 (1032)

Width

552 (21.7)

Fuel, lube oil & coolant

506 (1116)

Height

1258 (49.5)


General Data


Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



Generating Set Standards


The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


FG Wilson is a fully accredited ISO 9001 company.



Warranty

All equipment carries full manufacturer's warranty.


China 1500 RPM Perkins Diesel Generator , 404C-22G2 HS , 35 kVA supplier