Home /Inverters & Converters /

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar

Brand Name:SOROTEC
Certification:CE,ROHS,ISO9000
Model Number:SSP3117CY 1000VA - 5000VA
Minimum Order Quantity:USD10000
Delivery Time:Within 15-30days after receiving your 30% TT deposit
Payment Terms:30% TT in advance, the balance before shipping
Contact Now

Add to Cart

Active Member
Location: Shenzhen Guangdong
Address: Building B22 , Tantou West Industrial Park , Songgang Town , Bao'an District ,Shenzhen ,518105 P.R.CHINA
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar


Product snapshot:
Capacity : 1000W – 6000W


Nominal voltage : 220/230VAC


Nominal Frequency : 50/60HZ


Key Features:
■Pure sine wave inverter


■Built-in MPPT solar charge controller


■Selectable input voltage range for home appliances and personal computers


■Selectable charging current based on applications


■Configurable AC/Solar input priority via LCD setting


■Compatible to mains voltage or generator power


■Auto restart while AC is recovering


■Overload and short circuit protection


■Smart battery charger design for optimized battery performance


■Cold start function




Operation Diagrams and Working Conditions

Charge priority setting: Solar
Utility priority setting : Utility

1) When utility and solar are presented, battery charged from solar, Charger source will be turned to utility side in case solar panel without enough energy.



2) When solar source is not present, battery charged from utility source, load powered from utility


3) When utility source is not present, battery charged from solar source,load powered from solar and battery power.

4) When utility and solar are not present, connected load will be powered from battery.

Charge priority setting: Solar and Utility
Utility priority setting : Utility

When utility and solar are presented, battery charged from both solar and utility, load powered from utility.

Charge priority setting: Utility
Utility priority setting : Utility
When utility and solar are presented, battery charged from utility, load powered from utility.

Charge priority setting: Solar
Utility priority setting : Solar

When utility and solar are presented, battery charged from solar source, load powered from solar and battery. If solar priority, output source turn to utility side in case solar panel without energy or battery voltage down to pre-alarm level. If sbu priority, output source turn to utility side in case of battery voltage down to pre setting level.

Charge priority setting: Solar and Utility
Utility priority setting : Solar

When utility and solar are presented, battery charged from both solar and utility, load powered from solar and battery. If solar priority, output source turn to utility side in case solar panel without energy or battery voltage down to pre-alarm level. If sbu priority, output source turn to utility side in case of battery voltage down to pre setting level.

LCD Display Information:

Charging Controls:


Technical Specifications:

SPS3117CY Series
Wall mounted Integrated Solar Power Inverter technical specification
ModelSSP3117CY 1000VA-5000VA
Rated Power1000VA/800W1000VA/800W2000VA/1600W3000VA/2400W3000VA/2400W4000VA/3200W5000VA/4000W
INPUT
Voltage120VAC or 230VAC230VAC
Selectable Voltage Range95-140VAC or 170-280VAC(For Personal Computers)170-280VAC(For Personal Computers)
65-140VAC or 90-280VAC(For Home Appliances)90-280VAC(For Home Appliances)
Frequency Range50Hz/60Hz(Auto sensing)
OUTPUT
AC Voltage Regulation110/120VAC±5%(User selectable) or 230VAC ±5%230VAC ±5%
(Batt.Mode)
Surge Power2000VA4000VA6000VA8000VA10000VA
Efficiency(Peak)90%-93%93%
Transfer Time10ms(For Personal Computers)
20ms(For Home Appliances)
WaveformPure sine wave
BATTERY & AC CHARGER
Battery Voltage24VDC48VDC24VDC24VDC48VDC48VDC
Floating Charge Voltage27VDC54VDC27VDC27VDC54VDC54VDC
Overcharge Protection31VDC62VDC31VDC31VDC62VDC60VDC
Maximum Charge Current10A or 10A/20A*10A or 10A/15A*20A or 30A20A or 30A10A or 15A20A or 30A
SOLAR CHARGER
Maximum PV Array Power600W900W600W600W900W3000W
MPPT Range @ Operating30VDC~66VDC60VDC~88VDC30VDC~66VDC30VDC~66VDC60VDC~88VDC60VDC~115VDC
Voltage
Maximum PV Array Open75VDC102VDC75VDC75VDC102VDC145VDC
Circuit Voltage
Maximum Charge Current25A20A25A25A18A60A
Maximum Efficiency98%
Standby Power Consumption2W
PHYSICAL
Dimension,DxWxH(mm)128x272x355140x295x540
Net Weight(kgs)7.47.6812.513.5
OPERATING ENVIRONMENT
Humidity5% to 95% Relative Humidity(Non-condensing)
Operating Temperature0℃-55℃
Storage Temperature-15℃-60℃
Product specifications are subject to change without further notice
Inverter Power800W1000W1600W2400W2400W3200W4000W
Pmax.generated from25Amp,600W20Amp,900W25Amp,600W25Amp,600W20Amp,900W60Amp,3000W60Amp,3000W
solar charger
Best Panel Confguration500Wp1000Wp500Wp500Wp1500Wp3000Wp3000Wp
(250Wpx2pcs)(250Wpx4pcs)(250Wpx2pcs)(250Wpx2pcs)(250Wpx6pcs)(250Wpx12pcs)(250Wpx12pcs)

Wall Mounted UPS Power Inverter Overload protection With MPPT Solar


China Wall Mounted UPS Power Inverter Overload protection with MPPT Solar supplier

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar

Inquiry Cart 0