LZ-1902 Independent photoelectric smoke detector The full name of independent smoke detector is independent photoelectric smoke detector, referred to as independent smoke detector or independent smoke detector, which is one of the smoke alarm series products. The alarm adopts optical smoke inductive device and excellent production technology, stable work, beautiful appearance, simple installation, no need to debug, can be widely used in hotels,...
Shandong Jvante Fire Protection Technology Co., Ltd.
Verified Supplier
No. 313, Area A, huangtai international hardware city, No. 198 Lishan North Road, Jinan Tianqiao District, Shandong Province
RE46C190S16TF SOP16 Low Voltage Photoelectric Smoke Detector Ic Chip
LPCB C-9101 Conventional Combination Heat/Photoelectric Smoke Detector Feature ☆ Combined all the features of the C-9102 Optical and the C-9103 Heat detector ☆ LED for 360o vision ☆ Sensing chamber for exceptional dust proof ability ☆ Ideal alternative to Ionization detector ☆ Low profile design ☆ LPCB Approved Technical Specifications ☆ Standard: EN54-part 5 and part 7 ☆ Operating Voltage: 24VDC ☆ Operating Current: Standby Current: 0.1mA Alarm...
Jingo International CO., LTD
3/F, 8Bldg, guilin Industry Area,Baoan district,Shenzhen, China.
Photoelectric smoke detector powered by 9VDC battery with CE
www.jsustech-com.ecer.com Model Number:JS-SD21 Features: - Ceiling or wall mounting - Easy to install with mounting hardware included - 9VDC battery - Suitable for any room - Flash alarm indicator (red) - Test button for easy recommended monthly testing - Low battery signal - Safety clip feature, not allow mounting of smoke alarm without battery installed - photoelectric chamber for early detection from all directions - Loud 85dB alarm signal...
Addressable fire alarm 24V systems photoelectric smoke detector sensor
Addressable fire alarm 24V systems photoelectric smoke detector sensor Specification: Working voltage: DC24V ± 20% Working current: monitoring status <50uA, alarm status: 20mA Work instructions: monitoring status indicator flashes red once per 6 seconds, alarm status indicator light is lit. Weight: about 100g Dimensions:100mmx55mm Connection: non-polarity two wire Use of the environment: indoor, temperature -10 ℃ ~ 55 ℃, relative humidity ≤95%...
Jingo International CO., LTD
3/F, 8Bldg, guilin Industry Area,Baoan district,Shenzhen, China.
EN14604 certified photoelectric smoke detector
www.jsustech-com.ecer.com Model No.:JS-SM10 Features: 1. Photoelectric sensing technology – Detects Slow Smoldering Fires. 2. Sleek low-profile housing design. 3. SMD circuit board design - satisfactory quality and reliability guaranteed. 4. Fully supervised for low battery and low sensitivity. 5. Test button verifies battery and alarm operation. 6. Sounding a loud alarm signal of exceeding 85 dB(3m) in alarm mode. 7. Silence function (optional)....
Addressable fire alarm 24V systems photoelectric smoke detector sensor
Addressable fire alarm 24V systems photoelectric smoke detector sensor Specification: Working voltage: DC24V ± 20% Working current: monitoring status <50uA, alarm status: 20mA Work instructions: monitoring status indicator flashes red once per 6 seconds, alarm status indicator light is lit. Weight: about 100g Dimensions:100mmx55mm Connection: non-polarity two wire Use of the environment: indoor, temperature -10 ℃ ~ 55 ℃, relative humidity ≤95%...
Shenzhen KINGUI Limited
Address:3/F, 6Bldg, Guilin Industry Area,Baoan district,Shenzhen, China.
Independent Photoelectric Smoke Detector
www.jsustech-com.ecer.com Item No.JS-SD1A keywords: security alarms,gsm alarms,gas detector,gas sensor, gas alarms,wired gas dector...
www.jsustech-com.ecer.com Item No.JS-SD1A Operation voltage DC12V Static current 200uA max Alarm current 20mA max Detection Range 80m²(installed at 6m to 12m high); 60m²(installed at 6m below high) Alarm Indicator Red LED flashing Alarm Sound Level 85dB/m Working temperature -10℃ to +50℃ Environment Humidity 95%RH max Dimension Φ100*43mm Weight 180g Implementation standard GB4715-2005;EN14604 keywords: security alarms,gsm alarms,gas detector,gas...
www.jsustech-com.ecer.com Item No.JS-TD1A Operating Voltage DC12V Standby Current 2mA (relay NO) 12mA (relay NC) Alarm Current 15mA (relay NO) 5mA (relay NC) Alarm Indicator Red LED ON Environment Humidity 95%RH max Operating Temperature -10℃ to +85℃ Alarm Temperature 57℃ (135F°) Rate of Rising 8℃ (15F°)/min Detecting Range 60㎡ below installation height of 6m; 80㎡between installation height of 6-12m Alarm Output Relay output Contact Rating N/A...