Hydrophilic Fin Copper Tubes Crypto Mining Cooling Air Dry Coolers


What's Immersion Cooling?

Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.

Benefits of Immersion Cooling:


1. Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. With air-based cooling, servers require fans and HVAC systems to be running non-stop throughout the day. As a result, some large server rooms with high-density racks experience a noise level reaching almost 80db. Not only is it unbearably loud; these fans can account for roughly 25-30% in additional power required to keep compute equipment on-line. When your hardware remains submerged in a liquid-based system, fans are eliminated, further driving your PUE lower.


2. Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy. By definition, the most energy-efficient data center would have a PUE of 1.0. But, as we all know, this is nearly unattainable due to the PUE loss that occurs in power transformation and mechanical cooling load.

Legacy or underside air-cooled techniques can struggle to maintain a satisfactory PUE number, operating in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.

With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load. In doing so, immersion-cooled environments operate as some of the world’s greenest data centers.


3. Cost Savings - When it comes to operational overhead, cooling accounts for a large portion of opex. A facility that houses thousands of servers is expected to run 24/7, 365 days a year; with traditional air-cooling, that facility is now also deploying a huge quantity of fans, HVAC and CRAC systems as well. When servers are submerged in thermally conductive cooling solutions, heat is transferred more efficiently, electricity usage is reduced by more than 95%, and power bills are drastically reduced.


Technical parameter of Radiators
Dry cooler D3 series parameter(fin space 2.1mm)

Type

D3-042-

1X800

D3-046-

1X800

D3-051-

1X800

D3-087-

2X800

D3-094-

2X800

D3-103-

2X800

D3-125-

3X800

D3-146-

3X800

D3-153-

3X800

D3-175-

4X800

D3-188-

4X800

CapacityWater35℃ outdoor temp.Inlet45℃,KW42.146.150.687.393.6102.9124.9145.9153.3174.5187.9
outlet40℃
20% GlycolInlet45℃40.845.149.784.591.8100.9119.4143150.4168.9184.3
outlet40℃
MediumWater flowM3/h7.388.815.216.317.921.725.426.630.332.7
Pressure dropkPa4969974898932197894898
Air flowM3/h2145420531196964290641061393906436461585590878581182120
Fan motor(400V/3N/50HZ)W18001800180036003600360054005400540072007200
A3.83.83.87.67.67.611.411.411.415.215.2
FanNo X φ

1x1

x800

1x1

x800

1x1

x800

1x2

x800

1x2

x800

1x2

x800

1x3

x800

1x3

x800

1x3

x800

2x2

x800

2x2

x800

Sound pressure leveldB(A)5050505151515353535454
10m
DimensionLmm20002000200038003800380056005600560038003800
Wmm10841084108410841084108410841084210821082108
Hmm13281328132813281328132813281328132813281328
Amm17281728172835283528352853285328532835283528
B1mm------17641764176417761776177617641764
B2mm------17641764176417761776177617641764
B3mm------------177617761776----
B4mm----------------------
Xmm99799799799799799799799799720212021
Inlet φmm2”2”2”2 1/2”2 1/2”2 1/2”3’3’3’4”4”
Inlet φmm2”2”2”2 1/2”2 1/2”2 1/2”3’3’3’4”4”
Product weight(empty)kg2252332413573733927965277498121062

Recently shipped photos:




The immersion cooling system diagram by dry cooling tower: