Home /

18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation

18.5kw 22kw 220V Single Phase Solar Pump Inverter For Agricultural Irrigation

Brand Name:VEIKONG
Certification:CE
Model Number:VFD500-PV
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Solar pump inverter 18.5kw 22kw 220V single phase for agricultural irrigation


Key Advantages:

1. MPPT efficiency more than 99%.

2. Drives well all 1/3 phase AC pumps and PMSM in solar pumping system.
3. Voc of solar panel can set by manual or MPPT automatically tracking.
4. Solar DC & Grid AC power supply input both ok.
5. Dry run & Full water tank protection.
6. Short circuit, over load, over current... motor production.
7. The PQ (power/flow) performance curve enables calculating the flow output from the pump
8. Ambient temperature for using: -10 to +50˚C.
9. Inverter Power range: 220V, 0.75KW to 110KW. 380V/480V, 0.75KW to 250kw

Techincal Parameters:


1. Wake up and sleep function parameters:


P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
P47.06Light detection timeSee P47.05 for explanation.60s
P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

2. Dry runing protection function parameters:


P24.12Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14Dry run Unload detection time0.000s~60.000s30.000s
P24.15Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15


5.00Hz
P24.16Reset time of dry run protection0.0~6000.0240.0s
P23.21Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

3. Water full protection function parameters:


P47.18Full water level detection channel

0:ineffective

1:AI1

2:AI2

3:AI3

4:AI4

Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

0
P47.19Full water level detection value

0.0~100.0%


0.0%
P47.20Full water level detection time

0.0~3000.0s

When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.


10.0s
P47.21Full water recovery time

0.0~3000.0s

When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

10.0s

Support optional LCD keypad


Support optional GPRS Module

VEIKONG VFD500-PV 2.2KW 4KW picture:

VEIKONG Solar pump special parameter User mode fast quick start




VEIKONG Solar pump special parameter User mode fast quick start


Function codeNameDescriptionDefaultProperty
47 Group solar pumping special group
P00.03RESET

0:NO ACTION

11:Restore default parameter except for motor parameter and auto-tune related parameter and factory parameter

12:Restore default to factory parameter 13:Clear tripping record

0
P00.06Source of the Operation Command

0:keypad

1:terminal

2:communication

Ø Command source: run,stop,forward,reverse,jog,fast brake stop.etc

0
P00.07Numeric frequency setting00.00Hz~maximum frequency50.00Hz
P00.11Application Macro

01:Output three phase 50HZ

02:Output three phase 60hz

21:Output single phase with capacitor 50hz

22:Output single phase with capacitor 60hz

31:Output single phase without capacitor 50hz

32:Output single phase without capacitor 60hz

00
P01.06Maximum frequency10.00~600.00Hz50.00Hz
P01.08Upper limit frequencyLower limit frequency-maximum frequency50.00Hz
P07.03Relay 1 Output terminal function group(T1A T1B T1C)

0:No function

1:READY

2:RUN

3:Error1(stop fault)

4:Error2(same as Error1 except undervoltage)

5:Warning output(fault but in running)

3
P11.01AC asynchronous motor TYPE

0:Three phase AC asynchronous motor

1:Single phase AC asynchronous motor without starting capacitor

0
P11.02Motor rated power

0.1kW~710.0kW

Ø when power is less than 1kw ,0.75kw set to 0.8 as per round up principle ,0.55kw motor set 0.6

Ø when change motor rated power,AC drive will automatically set other parameter of motor name plate and motor model parameter be careful to use

Depend
P11.03Motor rated voltage10V~2000VDepend
P11.04Motor rated current

P11.02<30kW:0.01A

P11.02>=30kW:0.1A

Depend
P11.05Motor rated frequency1.00Hz~600.00Hz50.00Hz
P11.06Motor rated RPM1~60000rpmDepend
P21.00Monitoring display

0:Standard mode (display frequency only)

1:Automatic scrolling display(Check 3.1 in detail )it show hz,current,power and voltage

0