Temperature-Controlled Burn-In Test Chamber with 2400*1200*1600 mm Size and 460Vac Rated Voltage for EC Fan Drive Modules

Brand Name:CPET
Model Number:CP-CEF03
Minimum Order Quantity:2sets
Delivery Time:30 work days
Payment Terms:L/C
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: Building 1, No. 33, Patang Road, Loucun Community, Guangming District, Shenzhen, China XinHu Street,Guangming District, Shenzhen, China
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Burn-In Test Of Temperature-Controlled EC Fan Drive Module Support Customization


Scope of application
Mainly used in burn-in test of temperature-controlled EC fan drive module
Performance parameters
Skills requirementBurn-in cabinet size(mm)L2400*W1200*H1600
Rated working voltage460Vac
Rated insulation voltage690Vac
Rated frequency50Hz
Rated working current8.3A
Power frequency withstand
voltage for 1 minute
2500Vac
AC input specifications460Vac/8.3A
AC output specifications364Vac/8.35Amax
Master switch4way 100A
Input switch24way 16A
Output switch24way 16A
IP ratingIP20
Noise<70dB (measured at a distance of 1m from the device)
Structural requirementsDimension(mm)2400(W)*1200(D)*1600(H)
Burn-in slot layout
requirements
The bottom of the cabinet with 3 layers and 8 Burn-in slots on each floor needs to be reserved for 40CM installation inductance
Docking methodConnector supports 600VAC, 16A hard connection
Cabinet doorDouble door
Maintenance methodBefore and after maintenance
Monitor
and
indicate
Monitoring requirements

1.Electrical interface: RS485 communication, a total of 24 channels, each interface is isolated from each other


2.Communication distance: 6m


3.Working mode: asynchronous half-duplex


4.Photoelectric isolation: isolation voltage 2.5KVrms


5.Parameter setting: RS485 baud rate: 9.6-115.2Kbps


6.Monitoring parameters: power on / off control of each slot, voltage and current settings and readback, temperature and alarm information read


Safety requirements

1.Energy analysis of key components in short-circuit and over-current scenar
ios


2.With energy analysis in over-temperature and smoking scenes


3.The control circuit has a leakage protection function


Panel instructionsvEach slot indicator
China Temperature-Controlled Burn-In Test Chamber with 2400*1200*1600 mm Size and 460Vac Rated Voltage for EC Fan Drive Modules supplier