Industrial X Ray Ndt Testing Equipment RD-2505 X-Ray Flaw Detector

Brand Name:HUIWEI
Certification:ISO 9001, CE
Model Number:RD-2505
Minimum Order Quantity:1 set
Delivery Time:15working days
Payment Terms:L/C,T/T,Western Union,MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Hangzhou Zhejiang China
Address: No.3 Miaochangqiao Road, Liangzhu Street, Yuhang District, Hangzhou City, Zhejiang Province , China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Industrial X Ray Ndt Testing Equipment RD-2505 X-Ray Flaw Detector

Main introduction:

RD-2505 is an X-ray machine with automatic intelligent training machine control system. Its biggest feature is its high intensity anti-interference ability. Its working mode is continuous 4:1 working exposure, and the maximum exposure time is 15 minutes. This series of models is divided into directional and circumferential radiation models. The radiation angle of the directional machine is 40 ± 5 °, the circumferential radiation angle is 360 °, and the maximum penetration of A3 steel thickness is 45mm.

This model is a classic model for field and aerial operations with small size, light weight (generator weight 26kg), strong penetration ability and high stability.

Introduction

The industrial ndt x-ray equipment use to evaluate the quality of materials and products since the industrial ndt x-ray equipment can be used to show the internal defects of materials,products or welding from a radiographic image on a film. According to the principle of the different absorption of the x-ray for different material depending on the different thickness of the materials.


Main uses:

RD-2505 the technical parameters


Project

RD-2505

input

Input power

Single-phase 50Hz AC220V - 265V

Power supply capacity

No less than 2.0 KVA

output

X - ray tube voltage

150~ 250 KVp

X ray tube current

5mA

mA Stability degree

± 1%

Ray tube

Focal size

2.0× 2.0

X-ray irradiation range

40±5°

Ray generator

working pressure

Cooling mode

Insulation way

0.45MPa ~ 0.5Mpa

Anode ground connection radiator Strong wind cold

Gas insulation SF6

Size

weight (kg)

Φ280×610

26

Maximum penetration

Thickness steel A3(mm)

40 mmFe(5 min)

condition

focal distance 600mm ,Agfa film,Double lead foil,Liquid temperature 22,Film density 1.5

sensitivity

superior 2%

controller

Size

weight

Circuit

325×270×180

< 9(kg)

Automatic control and protection

Environment

working temperature relative humidity

Altitude

-30°~ +40°

Not more than 85%

Not higher 1500m

methods

fully automatic 4:1 Work and rest,Longest continuous exposure time 15mins


China Industrial X Ray Ndt Testing  Equipment RD-2505  X-Ray Flaw Detector supplier

Industrial X Ray Ndt Testing Equipment RD-2505 X-Ray Flaw Detector

Inquiry Cart 0