Add to Cart
Customized Solar Heat Pump 7KW 10KW 15KW R32 ACDC Air Source Heat Pump on-grid Inverter Solar Heater Pumps
Model | TRB-08CHW/VE | TRB-10CHW/VE | TRB-15CHW/VE | ||
Power Supply | V/Hz | 230V/30~80Hz | 230V/30~90Hz | 230V/30~90Hz | |
ErP Level / SCOP | 35°C | A+++ / 4.51 | A+++ / 4.51 | A+++ / 4.51 | |
ErP Level / SCOP | 55°C | A++ / 3.5 | A++ / 3.5 | A++ / 3.5 | |
(1)Heating Conditions:Ambient Air temp:7℃,Water inlet 30℃,Water outlet 35℃; | |||||
Heating (1) | Rated Heating Capacity (7°C/35°C) | kW | 8 | 10 | 15 |
Rated Input Power | kW | 1.95 | 2.47 | 3.68 | |
COP | w/w | 4.1 | 4.05 | 4.08 | |
(2)Heating Conditions:Ambient Air temp:7℃,Water inlet 50℃,Water outlet 55℃; | |||||
Heating (2) | Rated Heating Capacity (7°C/55°C) | kW | 6.5 | 8.8 | 13.2 |
Rated Input Power | kW | 2.36 | 3.22 | 4.80 | |
COP | w/w | 2.76 | 2.73 | 2.75 | |
(3)Heating Conditions:Ambient Air temp:2℃,Water inlet 30℃,Water outlet 35℃; | |||||
Heating (3) | Rated Heating Capacity (2°C/35°C) | kW | 6.5 | 8.6 | 13 |
Rated Input Power | kW | 1.78 | 2.38 | 3.58 | |
COP | w/w | 3.65 | 3.62 | 3.63 | |
(4)Heating Conditions:Ambient Air temp:2℃,Water inlet 50℃,Water outlet 55℃; | |||||
Heating (4) | Rated Heating Capacity (2°C/55°C) | kW | 6.3 | 8.5 | 12.5 |
Rated Input Power | kW | 2.68 | 3.66 | 5.34 | |
COP | w/w | 2.35 | 2.32 | 2.34 | |
(5)Heating Conditions:Ambient Air temp:-7℃,Water inlet 30℃,Water outlet 35℃; | |||||
Heating (5) | Rated Heating Capacity (-7°C/35°C) | kW | 6.2 | 8.3 | 12.2 |
Rated Input Power | kW | 1.85 | 3.55 | 3.65 | |
COP | w/w | 3.35 | 2.34 | 3.34 | |
(6)Heating Conditions:Ambient Air temp:-7℃,Water inlet 50℃,Water outlet 55℃; | |||||
Heating (6) | Rated Heating Capacity (-7°C/55°C) | kW | 5.8 | 7.6 | 11.5 |
Rated Input Power | kW | 2.66 | 3.52 | 5.35 | |
COP | w/w | 2.18 | 2.16 | 2.15 | |